The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
On-off-on fluorescent nanosensor for Fe3+ detection and cancer/normal cell differentiation via silicon-doped carbon quantum dots
Abstract
Abstract In this study, an on-off-on fluorescent nanosensor based on carbon quantum dots (or carbon dots, CDs) was successfully fabricated for Fe3+ detection and selective imaging of cancerous cells in vitro and in vivo. The multifunctional CDs were prepared by a one-pot solvothermal treatment of glycerol and a silane molecule (N-[3-(trimethoxysilyl)propyl]ethylenediamine, DAMO). The as-prepared CDs exhibited excellent fluorescence (FL) properties and favorable biocompatibility, and could realize wash-free cell imaging both in vitro (e.g., for bacterial and fungal cells) and in vivo (e.g., for zebrafish embryos). On the other hand, the fluorescence of CDs can respond to Fe3+ selectively and sensitively, with a very low detection limit of 16 nM. Besides, detection of Fe3+ in living cells and zebrafish was also successfully realized by the CDs. Moreover, it was found that glutathione (GSH) could enhance the fluorescence of the mixed solution of CDs and Fe3+ (CDs/Fe3+), and such a property could be utilized to efficiently distinguish cancerous cells from normal ones based on the difference in the content of GSH of the two types of cells. More importantly, GSH also realized the enhanced fluorescence signals of CDs/Fe3+ in tumor site in vivo after intravenous injection, indicating the potential of CDs/Fe3+ for imaging-guided precision cancer diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two to tango: Regulation of Mammalian iron metabolism
Hentze, M. W., Muckenthaler, M. U., Galy, B., & Camaschella, C. (2010) · Cell · doi:10.1016/j.cell.2010.06.028 · Cited by 2,120
Cited by
Principles, mechanisms, and application of carbon quantum dots in sensors: a review
Molaei, M. J. (2020) · Analytical Methods · doi:10.1039/c9ay02696g · Cited by 584
Carbon quantum dots and their biomedical and therapeutic applications: a review
Molaei, M. J. (2019) · RSC Advances · doi:10.1039/c8ra08088g · Cited by 538
Molaei, M. J. (2019) · Talanta · doi:10.1016/j.talanta.2018.12.042 · Cited by 469
Recent Advances in Synthesis, Optical Properties, and Biomedical Applications of Carbon Dots
Anwar, S., Ding, H., Xu, M., Hu, X., Li, Z., Wang, J., Liu, L., Jiang, L., Wang, D., Dong, C., et al. (2019) · ACS Applied Bio Materials · doi:10.1021/acsabm.9b00112 · Cited by 367
Future Perspectives and Review on Organic Carbon Dots in Electronic Applications
Semeniuk, M., Yi, Z., Poursorkhabi, V., Tjong, J., Jaffer, S., Lu, Z.-H., & Sain, M. (2019) · ACS Nano · doi:10.1021/acsnano.9b00688 · Cited by 367
Metadata
- Authors
- Gao, G., Jiang, Y.-W., Jia, H.-R., Yang, J., & Wu, F.-G.
- Venue
- Carbon
- Publisher
- Elsevier BV
- Published
- 2018-08
- Volume
- 134
- Pages
- 232-243
- ISSN
- 0008-6223 (ISSN-L)
- OpenAlex
- W2791470728
- Cited by
- 276
- References
- 1
- FWCI
- 12.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On-off-on fluorescent nanosensor for Fe3+ detection and cancer/normal cell differentiation via silicon-doped carbon quantum dots. https://app.cochat.ai/papers/10.1016/j.carbon.2018.02.063
- The paper
- Gao, G., Jiang, Y.-W., Jia, H.-R., Yang, J., & Wu, F.-G. (2018). On-off-on fluorescent nanosensor for Fe3+ detection and cancer/normal cell differentiation via silicon-doped carbon quantum dots. Carbon. https://doi.org/10.1016/j.carbon.2018.02.063
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.