Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 212

The DOI matches its Crossref record.

Connexin 43 expression and distribution in compensated and decompensated cardiac hypertrophy in patients with aortic stenosis

Kostin, S · 2004 · Cardiovascular Research

Abstract

OBJECTIVES: Gap junctions (GJ) are important determinants of conduction. In advanced heart failure alterations of the major ventricular GJ protein, connexin 43 (Cx43) are found. However, changes in Cx43 expression during the progression from compensated cardiac hypertrophy to heart failure, especially in humans, have not been studied extensively. The aim of the present study was to investigate changes in Cx43 expression and distribution in compensated and decompensated left ventricular (LV) hypertrophy in pressure-overloaded human hearts with valvular aortic stenosis (AS). METHODS: We measured Cx43 levels by Western blot and quantitative immunoconfocal microscopy of LV septum biopsies from three groups of patients with AS (group I (n=9): ejection fraction (EF)>50%; group II (n=12): EF 30-50%; group III (n=9): EF<30%). LV biopsies from six patients with mitral valve stenosis and two donor hearts served as controls. RESULTS: Only the early phase of LV hypertrophy (AS-I) was characterized by extensive Cx43 lateral staining. As compared to controls, the AS-I group showed a 44.3% increase in Cx43 protein, which was reflected in an augmented number of GJs per 100 microm(2) intercalated disc area (control: 62.5+/-6.4 vs. AS-I: 79.8+/-4, p<0.001) and an increased GJ surface density (control: 0.00547 vs. AS-I: 0.00724 microm(2)/microm(3), p<0.01). Decompensated LV hypertrophy (AS-III) was specified by reduced percentage of the Cx43 signal per myocyte area (control: 1.74% vs. AS-III: 1.31%, p<0.01) or per intercalated disc (control: 18.3% vs. AS-III: 11.3%, p<0.005). Mean GJ area and GJ number per intercalated discs in the AS-III group were decreased significantly by, respectively, 42.5% and 36.4% as compared to control. In addition, decompensated LV myocardium showed a markedly heterogeneous spatial distribution of Cx43. CONCLUSION: The quantity and spatial distribution of Cx43 differs markedly between compensated and decompensated LV hypertrophy in human patients with AS. Upregulation of Cx43 in compensated hypertrophy may represent the immediate adaptive response to increased load, whereas diminished and heterogeneous Cx43 distribution in decompensated hypertrophy may play maladaptive roles culminating in heart failure and ventricular arrhythmias.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cardiores.2003.12.010

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 212

Metadata

Authors
Kostin, S.
Venue
Cardiovascular Research
Published
2004-05-01
Volume
62
Issue
2
Pages
426-436
ISSN
0008-6363 (ISSN-L)
OpenAlex
W2109422517
Cited by
212
References
0
FWCI
2.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Connexin 43 expression and distribution in compensated and decompensated cardiac hypertrophy in patients with aortic stenosis. https://app.cochat.ai/papers/10.1016/j.cardiores.2003.12.010
The paper
Kostin, S. (2004). Connexin 43 expression and distribution in compensated and decompensated cardiac hypertrophy in patients with aortic stenosis. Cardiovascular Research. https://doi.org/10.1016/j.cardiores.2003.12.010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.