Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 281

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Long-term effects of polymer-based, slow-release, sirolimus-eluting stents in a porcine coronary model

CARTER, A · 2004 · Cardiovascular Research

Abstract

BACKGROUND: Stent-based delivery of sirolimus (SRL) has shown reduction in neointimal hyperplasia and restenosis. The purpose of this study was to evaluate the chronic vascular response and the expression of cell cycle regulators after SRL-eluting stent implantation in a porcine coronary model. METHODS: Forty-nine pigs underwent placement of 109 oversized stents (control, n=54, SRL (140 microg/cm(2)), n=55) in the coronary arteries with histologic analysis and Western blot (PCNA, p27(kip1), CD45, MCP-1, IL-2, IL-6, TNF-beta) at 3, 30, 90 or 180 days. RESULTS: At 3 days, the mean thrombus area was similar for control (0.38+/-0.19 mm(2)) and SRL (0.29+/-0.09 mm(2)) stents. After 30 days, the mean neointimal area was significantly less for the SRL (1.40+/-0.35 mm(2)) versus the control stents (2.94+/-1.28 mm(2), p<0.001). At 90 and 180 days, the mean neointimal area was similar for the SRL (3.03+/-0.92 and 3.34+/-0.99 mm(2)) as compared with control stents (3.45+/-1.09 and 3.65+/-1.23 mm(2)). Western blot analysis demonstrated an increased expression of p27(kip1) in the vessel wall at 90 days for the SRL versus control stents (p=0.05) but with increased levels of PCNA in the SRL as compared with control stents (p=0.003). CONCLUSION: SRL-eluting stents favorably modulate neointimal formation for 30 days in the porcine coronary model. Long-term inhibition of neointimal hyperplasia is not sustained presumably due to delayed cellular proliferation despite increased levels of the cyclin-dependent kinase p27(kip1) in the vessel wall.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cardiores.2004.04.029

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 281

Metadata

Authors
CARTER, A.
Venue
Cardiovascular Research
Published
2004-09
Volume
63
Issue
4
Pages
617-624
ISSN
0008-6363 (ISSN-L)
OpenAlex
W2095916495
Cited by
281
References
10
FWCI
22.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long-term effects of polymer-based, slow-release, sirolimus-eluting stents in a porcine coronary model. https://app.cochat.ai/papers/10.1016/j.cardiores.2004.04.029
The paper
CARTER, A. (2004). Long-term effects of polymer-based, slow-release, sirolimus-eluting stents in a porcine coronary model. Cardiovascular Research. https://doi.org/10.1016/j.cardiores.2004.04.029

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.