The DOI matches its Crossref record.
Stent-Based Delivery of Sirolimus Reduces Neointimal Formation in a Porcine Coronary Model
Open accessAbstract
Background — The purpose of this study was to determine the efficacy of stent-based delivery of sirolimus (SRL) alone or in combination with dexamethasone (DEX) to reduce in-stent neointimal hyperplasia. SRL is a potent immunosuppressive agent that inhibits SMC proliferation by blocking cell cycle progression. Methods and Results — Stents were coated with a nonerodable polymer containing 185 μg SRL, 350 μg DEX, or 185 μg SRL and 350 μg DEX. Polymer biocompatibility studies in the porcine and canine models showed acceptable tissue response at 60 days. Forty-seven stents (metal, n=13; SRL, n=13; DEX, n=13; SRL and DEX, n=8) were implanted in the coronary arteries of 16 pigs. The tissue level of SRL was 97±13 ng/artery, with a stent content of 71±10 μg at 3 days. At 7 days, proliferating cell nuclear antigen and retinoblastoma protein expression were reduced 60% and 50%, respectively, by the SRL stents. After 28 days, the mean neointimal area was 2.47±1.04 mm 2 for the SRL alone and 2.42±1.04 mm 2 for the combination of SRL and DEX compared with the metal (5.06±1.88 mm 2 , P <0.0001) or DEX-coated stents (4.31±3.21 mm 2 , P <0.001), resulting in a 50% reduction of percent in-stent stenosis. Conclusions — Stent-based delivery of SRL via a nonerodable polymer matrix is feasible and effectively reduces in-stent neointimal hyperplasia by inhibiting cellular proliferation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Chen, C.-J., Kono, H., Golenbock, D., Reed, G., Akira, S., & Rock, K. L. (2007) · Nature Medicine · doi:10.1038/nm1603 · Cited by 876
Systemic inflammation in heart failure – The whys and wherefores
Yndestad, A., Kristian Damås, J., Øie, E., Ueland, T., Gullestad, L., & Aukrust, P. (2006) · Heart Failure Reviews · doi:10.1007/s10741-006-9196-2 · Cited by 294
The Roles of Hypoxia in the In Vitro Engineering of Tissues
Malda, J., Klein, T. J., & Upton, Z. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0417 · Cited by 282
The role of the inflammasome in nonmyeloid cells
Yazdi, A. S., Drexler, S. K., & Tschopp, J. (2010) · Journal of Clinical Immunology · doi:10.1007/s10875-010-9437-y · Cited by 76
Metadata
- Authors
- Suzuki, T., Kopia, G., Hayashi, S.-I., Bailey, L. R., Llanos, G., Wilensky, R., Klugherz, B. D., Papandreou, G., Narayan, P., Leon, M. B., Yeung, A. C., Tio, F., Tsao, P. S., Falotico, R., & Carter, A. J.
- Venue
- Circulation
- Published
- 2001-09-04
- Volume
- 104
- Issue
- 10
- Pages
- 1188-1193
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2121718174
- Cited by
- 708
- References
- 0
- FWCI
- 57.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stent-Based Delivery of Sirolimus Reduces Neointimal Formation in a Porcine Coronary Model. https://app.cochat.ai/papers/10.1161/hc3601.093987
- The paper
- Suzuki, T., Kopia, G., Hayashi, S.-I., Bailey, L. R., Llanos, G., Wilensky, R., Klugherz, B. D., Papandreou, G., Narayan, P., Leon, M. B., Yeung, A. C., Tio, F., Tsao, P. S., Falotico, R., & Carter, A. J. (2001). Stent-Based Delivery of Sirolimus Reduces Neointimal Formation in a Porcine Coronary Model. Circulation. https://doi.org/10.1161/hc3601.093987
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.