CoChat

Effects of hemoglobin C, D, E, and S traits on measurements of HbA1c by six methods

Open access
Lin, Chia-Ni, Emery, Todd J., Little, Randie R., Hanson, Steve E., Rohlfing, Curt L., Jaisson, Stéphane, Gillery, Philippe, Roberts, William L. · 2012 · Clinica Chimica Acta
Cited by 68

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Glycated hemoglobin is hemoglobin that has been irreversibly modified by addition of glucose through a non-enzymatic process and provides a weighted average of plasma glucose concentration over the erythrocyte lifespan. HbA1c is a specific glycated hemoglobin that is modified at the N-terminal valine of the Hb beta chains. HbA1c therefore provides a useful estimate of mean glycemia in patients with diabetes that has been shown to be directly related to risks for diabetes complications. Treatment goals for HbA1c have been established, and more recently the test has been recommended for use in diagnosing diabetes [1,2]. Therefore, accurate and precise measurement of HbA1c is extremely important. The most common hemoglobin variants worldwide are HbS, HbE, HbC and HbD traits. Previous studies have shown method-specific analytic interference with HbA1c results from these heterozygous hemoglobin variants. This study was approved by the University of Utah Institutional Review Board. Whole blood samples from individuals homozygous for HbA (n=42) and heterozygous for HbC, HbD, HbE, or HbS trait (n=23, n=41, n=76, n=40, respectively) were collected in EDTA tubes. Samples were frozen at −70 °C in small aliquots and shipped on dry ice to 4 sites for HbA1c analysis. Hemoglobin variants were identified by inspection of chromatograms obtained with a Bio-Rad Variant analyzer (Bio-Rad Laboratories, Hercules, CA) using the β Thal Short Program; samples with HbF >5% were excluded. Samples with HbA1c concentrations of 4–12% were included in this study. The evaluation included four ion-exchangeHPLCmethods: Variant II Turbo 2.0 (Bio-Rad Laboratories, Hercules, CA), ADAMS A1c HA-8180V (ARKRAY, Japan), and G7 and G8 (Tosoh Biosciences, San Francisco, CA), one boronate affinity method: In2it (Bio-Rad) and one capillary electrophoresis method: Capillarys2 Flex Piercing HbA1c (Sebia, Lisses, France). A boronate affinity HPLC method: ultra (Trinity Biotech, Kansas City, MO) was used as the comparative method since it has previously been shown to be unaffected by the presence of hemoglobin variants [3]. An overall test of coincidence of 2 least-squares linear regression lines was performed using SAS Software (SAS Institute, Cary NC) to determine whether the presence of each hemoglobin variant caused a statistically significant difference (Pb0.05) in results relative to the comparative method. Deming regression analysis was performed

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cca.2011.12.019

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 68

Metadata

Authors
Lin, C.-N., Emery, T. J., Little, R. R., Hanson, S. E., Rohlfing, C. L., Jaisson, S., Gillery, P., & Roberts, W. L.
Venue
Clinica Chimica Acta
Publisher
Elsevier BV
Published
2012-04
Volume
413
Issue
7-8
Pages
819-821
ISSN
0009-8981 (ISSN-L)
OpenAlex
W2043316292
Cited by
68
References
2
FWCI
3.33
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.