The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Fluorescent probes for the imaging of lipid droplets in live cells
Abstract
Abstract Lipid droplets (LDs) are cellular organelles that are essential for maintaining lipid and energy homeostasis. Once regarded as merely inert fat particles, they are now recognized as highly dynamic, mobile organelles required for preventing lipotoxicity and for interacting and cooperating with various organelles. Despite the progress made in understanding the role of LDs, a number of fundamental questions remain unanswered. Effective imaging agents for observing the morphology and dynamic physiological processes of LDs in cells could help address this knowledge gap. Such probes are expected to aid in our understanding of LDs and facilitate the development of new and effective therapeutics. In this review, we have provided a brief introduction to the formation and physiological functions of LDs in an attempt to highlight the importance of these underappreciated organelles. Recent examples of LD-based fluorescent probes are discussed, including the fluorescence phenomenon used in their design. To date, both intramolecular charge transfer (ICT) and aggregation-induced emission (AIE) fluorescence mechanisms have been exploited to create LD probes. However, alternative strategies can be envisioned. We hope the readers will be enlightened as to the importance of these key organelles, will be poised to exploit existing probes to explore various biological applications, and be inspired to create new LD fluorescent sensors that will further our understanding of LDs and their associated physiology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aggregation-induced emission of 1-methyl-1,2,3,4,5-pentaphenylsilole
Luo, J., Xie, Z., Lam, J. W. Y., Cheng, L., Tang, B. Z., Chen, H., Qiu, C., Kwok, H. S., Zhan, X., Liu, Y., et al. (2001) · Chemical Communications · doi:10.1039/b105159h · Cited by 8,358
Grabowski, Z. R., Rotkiewicz, K., & Rettig, W. (2003) · Chemical Reviews · doi:10.1021/cr940745l · Cited by 3,714
Dynamics and functions of lipid droplets
Olzmann, J. A., & Carvalho, P. (2019) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-018-0085-z · Cited by 2,740
Human Fatty Liver Disease: Old Questions and New Insights
Cohen, J. C., Horton, J. D., & Hobbs, H. H. (2011) · Science · doi:10.1126/science.1204265 · Cited by 2,089
Johansson, M., Rocha, N., Zwart, W., Jordens, I., Janssen, L., Kuijl, C., Olkkonen, V. M., & Neefjes, J. (2007) · The Journal of Cell Biology · doi:10.1083/jcb.200606077 · Cited by 505
Cited by
Recent progress in the development of fluorescent probes for imaging pathological oxidative stress
Geng, Y., Wang, Z., Zhou, J., Zhu, M., Liu, J., & James, T. D. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00172a · Cited by 351
Self-citation
Metadata
- Authors
- Tian, H., Sedgwick, A. C., Han, H.-H., Sen, S., Chen, G.-R., Zang, Y., Sessler, J. L., James, T. D., Li, J., & He, X.-P.
- Venue
- Coordination Chemistry Reviews
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 427
- Pages
- 213577
- ISSN
- 0010-8545 (ISSN-L)
- OpenAlex
- W3088258528
- Cited by
- 251
- References
- 5
- FWCI
- 10.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescent probes for the imaging of lipid droplets in live cells. https://app.cochat.ai/papers/10.1016/j.ccr.2020.213577
- The paper
- Tian, H., Sedgwick, A. C., Han, H.-H., Sen, S., Chen, G.-R., Zang, Y., Sessler, J. L., James, T. D., Li, J., & He, X.-P. (2021). Fluorescent probes for the imaging of lipid droplets in live cells. Coordination Chemistry Reviews. https://doi.org/10.1016/j.ccr.2020.213577
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.