The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Evaluation of Cu2+, Co2+ and Ni2+ ions removal from aqueous solution using a novel chitosan/clinoptilolite composite: Kinetics and isotherms
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kinetics of Adsorption on Carbon from Solution
Weber, W. J., & Morris, J. C. (1963) · Journal of the Sanitary Engineering Division · doi:10.1061/jsedai.0000430 · Cited by 9,844
Recent developments in polysaccharide-based materials used as adsorbents in wastewater treatment
Crini, G. (2005) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2004.11.002 · Cited by 2,183
Interactions of metal ions with chitosan-based sorbents: a review
Guibal, E. (2004) · Separation and Purification Technology · doi:10.1016/j.seppur.2003.10.004 · Cited by 1,850
Sorption isotherms: A review on physical bases, modeling and measurement
Limousin, G., Gaudet, J.-P., Charlet, L., Szenknect, S., Barthès, V., & Krimissa, M. (2007) · Applied Geochemistry · doi:10.1016/j.apgeochem.2006.09.010 · Cited by 1,724
Ho, Y.-S. (2006) · Water Research · doi:10.1016/j.watres.2005.10.040 · Cited by 1,325
Removal of copper(II) ions from aqueous solution onto chitosan and cross-linked chitosan beads
Wan Ngah, W. S., Endud, C. S., & Mayanar, R. (2002) · Reactive and Functional Polymers · doi:10.1016/s1381-5148(01)00113-4 · Cited by 938
Chen, A.-H., Liu, S.-C., Chen, C.-Y., & Chen, C.-Y. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.10.009 · Cited by 511
Removal of arsenic (III) and arsenic (V) from aqueous medium using chitosan-coated biosorbent
Boddu, V. M., Abburi, K., Talbott, J. L., Smith, E. D., & Haasch, R. (2008) · Water Research · doi:10.1016/j.watres.2007.08.014 · Cited by 504
Liu, C., Bai, R., & San Ly, Q. (2008) · Water Research · doi:10.1016/j.watres.2007.10.031 · Cited by 446
Bayramoğlu, G., Altıntaş, B., & Arica, M. Y. (2009) · Chemical Engineering Journal · doi:10.1016/j.cej.2009.04.051 · Cited by 400
Cited by
Adsorption of dyes and heavy metal ions by chitosan composites: A review
Wan Ngah, W. S., Teong, L. C., & Hanafiah, M. A. K. M. (2011) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2010.11.004 · Cited by 2,045
Design and applications of interpenetrating polymer network hydrogels. A review
Dragan, E. S. (2014) · Chemical Engineering Journal · doi:10.1016/j.cej.2014.01.065 · Cited by 992
Self-citationChitosan: A Natural Biopolymer with a Wide and Varied Range of Applications
Jiménez-Gómez, C. P., & Cecilia, J. A. (2020) · Molecules · doi:10.3390/molecules25173981 · Cited by 817
Malamis, S., & Katsou, E. (2013) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2013.03.024 · Cited by 548
Habiba, U., Afifi, A. M., Salleh, A., & Ang, B. C. (2017) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2016.06.028 · Cited by 433
Metadata
- Authors
- Dinu, M. V., & Dragan, E. S.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2010-05
- Volume
- 160
- Issue
- 1
- Pages
- 157-163
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W2036032046
- Cited by
- 280
- References
- 23
- FWCI
- 15.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Cu2+, Co2+ and Ni2+ ions removal from aqueous solution using a novel chitosan/clinoptilolite composite: Kinetics and isotherms. https://app.cochat.ai/papers/10.1016/j.cej.2010.03.029
- The paper
- Dinu, M. V., & Dragan, E. S. (2010). Evaluation of Cu2+, Co2+ and Ni2+ ions removal from aqueous solution using a novel chitosan/clinoptilolite composite: Kinetics and isotherms. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2010.03.029
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.