CO2 capture using a novel hybrid monolith (H-ZSM5/activated carbon) as adsorbent by combined vacuum and electric swing adsorption (VESA)
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Abstract Electrical swing adsorption (ESA) is an interesting cyclic adsorption technology which relies on rapid Joule heating of the adsorbent to liberate adsorbed molecules such as CO2. In this study we used a novel hybrid zeolite/activated carbon honeycomb to implement ESA and compared it to conventional vacuum swing adsorption (VSA) for CO2 capture. We then combined electrical and vacuum swing adsorption (VESA) to assess the merits of this dual regeneration technology for recovering CO2 from a 15% CO2/N2 gas stream at low pressure. With a simple VSA-only cycle, a CO2 downstream purity of only 17–23% was achievable when the desorption pressures varied from 30 to 10 kPa. This was primarily due to the adsorbent’s poor adsorption characteristics which provided little change in CO2 adsorption capacity over this pressure range. A CO2 product purity of 15–34% and a recovery of 29–78% was achieved with ESA as the electrification time was extended from 30 s to 180 s. The combined VESA process provided a CO2 purity of 33% and recovery of 72% with a short electrification time of 30 s at a mild desorption pressure of 10 kPa. Energy calculations indicate that the total specific energy for VESA was lower than ESA alone but still higher than VSA, although the latter suffered from low purity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-Stage VPSA Process for CO2 Capture from Flue Gas Using Activated Carbon Beads
Shen, C., Liu, Z., Li, P., & Yu, J. (2012) · Industrial & Engineering Chemistry Research · doi:10.1021/ie202097y · Cited by 138
Cited by
Adsorption of Carbon Dioxide for post-combustion capture: a review
Raganati, F., Miccio, F., & Ammendola, P. (2021) · Energy & Fuels · doi:10.1021/acs.energyfuels.1c01618 · Cited by 661
Review on Reactor Configurations for Adsorption-Based CO 2 Capture
Dhoke, C., Zaabout, A., Cloete, S., & Amini, S. (2021) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.0c04547 · Cited by 240
Carbon Capture Technologies: A Review on Technology Readiness Level
Hekmatmehr, H., Esmaeili, A., Pourmahdi, M., Atashrouz, S., Abedi, A., Ali Abuswer, M., Nedeljkovic, D., Latifi, M., Farag, S., & Mohaddespour, A. (2024) · Fuel · doi:10.1016/j.fuel.2024.130898 · Cited by 189
Performance-Based Screening of Porous Materials for Carbon Capture
Farmahini, A. H., Krishnamurthy, S., Friedrich, D., Brandani, S., & Sarkisov, L. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01266 · Cited by 7
Metadata
- Authors
- Zhao, Q., Wu, F., Men, Y., Fang, X., Zhao, J., Xiao, P., Webley, P. A., & Grande, C. A.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2019-02
- Volume
- 358
- Pages
- 707-717
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W2893621787
- Cited by
- 88
- References
- 1
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.