Efficiently degradation of perfluorooctanoic acid in synergic electrochemical process combining cathodic electro-Fenton and anodic oxidation
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
A synergic electrochemical process between cathodic electro-Fenton and anodic oxidation was proposed for efficient degradation of perfluorooctanoic acid (PFOA) in this work. The electron-transfer ability and hydroxyl radicals ( OH) concentration are the key parameters for the PFOA degradation efficiency. Boron-doped diamond (BDD) anode exhibited the highest anodic oxidation ability compared to platinum and carbon stick. The integrated FeMn-doped carbon aerogel was fabricated as cathode for in-situ enhancing the generation of OH. The X-ray photoelectron spectroscopy (XPS) and near-edge X-ray absorption fine structure (NEXAFS) indicated the main composition of cathode is Fe0 and MnO. The Fe in the integrated cathode favors the electro-catalytic ability of oxygen reduction reaction (ORR), while MnO enhances the selectivity of 2-electron ORR with H2O2 as main product. The electroformed H2O2 would be onsite catalytic decomposition with FeII and MnII as Fenton catalysts for in-situ generating OH radicals. The optimal cathode with Fe/10Mn weight ratio can generate the highest concentration of OH. The catalytic degradation efficiency in this synergic electro-catalysis process with BDD as anode and Fe10MnC as cathode reached nearly 97% PFOA removal and 93% TOC removal after 4 h, suggesting the prominent synergic combination of cathodic electro-Fenton and anodic oxidation. The amount of intermediates C6F13COO− was decreased while others including C5F11COO−, C4F9COO−, C3F7COO−, C2F5COO−, CF3COO− were increased with increasing electro-catalysis time. The NEXAFS analysis of F in solution and cathode surface further confirmed the continuously synergic electro-catalysis between anodic and cathodic electro-Fenton oxidation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of XPS spectra of Fe2+ and Fe3+ ions in oxide materials
Yamashita, T., & Hayes, P. (2008) · Applied Surface Science · doi:10.1016/j.apsusc.2007.09.063 · Cited by 6,673
Liu, Z., Cheng, H., Li, N., Ma, T. Y., & Su, Y. (2016) · Advanced Materials · doi:10.1002/adma.201506197 · Cited by 736
Fluorinated organics in the biosphere
Key, B. D., Howell, R. D., & Criddle, C. S. (1997) · Environmental Science & Technology · doi:10.1021/es961007c · Cited by 729
Perfluorinated Surfactants and the Environmental Implications of Their Use in Fire-Fighting Foams
Moody, C. A., & Field, J. A. (2000) · Environmental Science & Technology · doi:10.1021/es991359u · Cited by 707
Trojanowicz, M., Bojanowska-Czajka, A., Bartosiewicz, I., & Kulisa, K. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.10.153 · Cited by 550
Electrochemical oxidation of perfluorinated compounds in water
Niu, J., Li, Y., Shang, E., Xu, Z., & Liu, J. (2016) · Chemosphere · doi:10.1016/j.chemosphere.2015.11.115 · Cited by 243
Physicochemical properties and aquatic toxicity of poly- and Perfluorinated compounds
Ding, G., & Peijnenburg, W. J. G. M. (2013) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2011.627016 · Cited by 241
Cited by
Lenka, S. P., Kah, M., & Padhye, L. P. (2021) · Water Research · doi:10.1016/j.watres.2021.117187 · Cited by 755
Lu, D., Sha, S., Luo, J., Huang, Z., & Zhang Jackie, X. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2019.121963 · Cited by 275
Kwon, G., Bhatnagar, A., Wang, H., Kwon, E. E., & Song, H. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.123242 · Cited by 255
Liu, M., Feng, Z., Luan, X., Chu, W., Zhao, H., & Zhao, G. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.0c08018 · Cited by 248
Self-citationMoradi, M., Vasseghian, Y., Khataee, A., Kobya, M., Arabzade, H., & Dragoi, E.-N. (2020) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2020.03.038 · Cited by 219
Olvera-Vargas, H., Gore-Datar, N., Garcia-Rodriguez, O., Mutnuri, S., & Lefebvre, O. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.126524 · Cited by 214
Recent advances in electro-Fenton process and its emerging applications
Nidheesh, P. V., Ganiyu, S. O., Martínez-Huitle, C. A., Mousset, E., Olvera-Vargas, H., Trellu, C., Zhou, M., & Oturan, M. A. (2023) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2022.2093074 · Cited by 197
“Copyright 2015, American Chemical Society), (d) mineralization of PFOA solution with BDD, Pt or carbon stick anode (Reprinted with permission from (Wang et al., 2019).”
MethodRemediation of water from per-/poly-fluoroalkyl substances (PFAS)–Challenges and perspectives
Garg, S., Wang, J., Kumar, P., Mishra, V., Arafat, H., Sharma, R. S., & Dumée, L. F. (2021) · Journal of Environmental Chemical Engineering · doi:10.1016/j.jece.2021.105784 · Cited by 139
Metadata
- Authors
- Wang, Q., Liu, M., Zhao, H., Chen, Y., Xiao, F., Chu, W., & Zhao, G.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2019-12
- Volume
- 378
- Pages
- 122071
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W2955078992
- Cited by
- 142
- References
- 7
- FWCI
- 5.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.