3D TiO2@nitrogen-doped carbon/Fe7S8 composite derived from polypyrrole-encapsulated alkalized MXene as anode material for high-performance lithium-ion batteries
The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
Abstract Nowadays, Ti3C2Tx MXene has been reported to afford an ideal platform for the growth of TiO2 by oxidation. Unfortunately, the TiO2 derived from Ti3C2Tx still possesses low lithium ion diffusion coefficient, poor electrical conductivity and relatively inferior capacity when used as anode of rechargeable lithium ion batteries (LIBs). In this work, three dimensional (3D) TiO2@nitrogen-doped carbon (NC)/Fe7S8 composite was fabricated by a facile and simple hybrid strategy via in situ polymerization of pyrrole monomer with alkalized Ti3C2Tx and subsequent vulcanization at 700 °C. When evaluated as an anode material for LIBs, the TiO2@NC/Fe7S8 demonstrates a high reversible capacity (516 mAh g−1 after 100 cycles at 0.1 A g−1), excellent rate capability (337 mAh g−1 at 1 A g−1) and robust long cycling stability (282 mAh g−1 after 1000 cycles at 4 A g−1). The excellent electrochemical performances are contributed by the unique architecture of TiO2@NC/Fe7S8, where 3D urchin-like TiO2 with good structural stability provides adequate space to increase the contact between electrode and electrolyte, shorten the lithium ion diffusion length and alleviate the volume change; nitrogen-doped carbon shell layer improves the electrical conductivity, facilitates the electron transport and prevents the aggregation for Fe7S8; Fe7S8 contributes high specific capacity during charge/discharge process. Importantly, the hybrid approach in this work enlightens the exploration on combing the MXene-derived oxides with other metal sulfides for promising applications in energy storage field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2D metal carbides and nitrides (MXenes) for energy storage
Anasori, B., Lukatskaya, M. R., & Gogotsi, Y. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.98 · Cited by 7,440
Two-Dimensional, Ordered, Double Transition Metals Carbides (MXenes)
Anasori, B., Xie, Y., Beidaghi, M., Lu, J., Hosler, B. C., Hultman, L., Kent, P. R. C., Gogotsi, Y., & Barsoum, M. W. (2015) · ACS Nano · doi:10.1021/acsnano.5b03591 · Cited by 2,110
Applications of 2D MXenes in energy conversion and storage systems
Pang, J., Mendes, R. G., Bachmatiuk, A., Zhao, L., Ta, H. Q., Gemming, T., Liu, H., Liu, Z., & Rummeli, M. H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00324f · Cited by 1,951
Zhou, W., Yin, Z., Du, Y., Huang, X., Zeng, Z., Fan, Z., Liu, H., Wang, J., & Zhang, H. (2013) · Small · doi:10.1002/smll.201201161 · Cited by 1,258
Peng, C., Yang, X., Li, Y., Yu, H., Wang, H., & Peng, F. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b11973 · Cited by 847
Naguib, M., Mashtalir, O., Lukatskaya, M. R., Dyatkin, B., Zhang, C., Presser, V., Gogotsi, Y., & Barsoum, M. W. (2014) · Chem. Commun. · doi:10.1039/c4cc01646g · Cited by 800
Hong Ng, V. M., Huang, H., Zhou, K., Lee, P. S., Que, W., Xu, J. Z., & Kong, L. B. (2017) · Journal of Materials Chemistry A · doi:10.1039/c6ta06772g · Cited by 784
Insertion-Type Electrodes for Nonaqueous Li-Ion Capacitors
Aravindan, V., Gnanaraj, J., Lee, Y.-S., & Madhavi, S. (2014) · Chemical Reviews · doi:10.1021/cr5000915 · Cited by 726
Lian, P., Dong, Y., Wu, Z.-S., Zheng, S., Wang, X., Wang, S., Sun, C., Qin, J., Shi, X., & Bao, X. (2017) · Nano Energy · doi:10.1016/j.nanoen.2017.08.002 · Cited by 712
Dong, Y., Wu, Z.-S., Zheng, S., Wang, X., Qin, J., Wang, S., Shi, X., & Bao, X. (2017) · ACS Nano · doi:10.1021/acsnano.7b01165 · Cited by 656
Cited by
Recent Advances in Oxidation Stable Chemistry of 2D MXenes
Cao, F., Zhang, Y., Wang, H., Khan, K., Tareen, A. K., Qian, W., Zhang, H., & Ågren, H. (2022) · Advanced Materials · doi:10.1002/adma.202107554 · Cited by 648
Metadata
- Authors
- Zhang, X., Li, J., Li, J., Han, L., Lu, T., Zhang, X., Zhu, G., & Pan, L.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 385
- Pages
- 123394
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W2983662046
- Cited by
- 168
- References
- 54
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.