CoChat

Removal of heavy metal ions using a new high performance nanofiltration membrane modified with curcumin boehmite nanoparticles

Moradi, Golshan, Zinadini, Sirus, Rajabi, Laleh, Ashraf Derakhshan, Ali · 2020 · Chemical Engineering Journal
Cited by 181

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The PES/B-Cur membranes were prepared by incorporating boehmite nanoparticles functionalized with curcumin (B-Cur) into PES membrane via phase inversion method. The PES/B-Cur membranes were characterized in terms of average pore size, pore size distribution, porosity, specific surface area, water contact angle, and zeta potential. Characterization techniques like ATR-IR, XRD, and XPS were used to confirm the presence of B-Cur nanoparticles in the PES/B-Cur membranes. The morphological properties of B-Cur nanoparticles and the PES/B-Cur membranes were studied using FESEM. performance of the membranes was also evaluated for pure water flux, antifouling behavior, and removal of heavy metal ions (Fe2+, Cu2+, pb2+, Mn2+, Ni2+, and Zn2+). The PES/B-Cur membrane showed relatively high pure water flux (120–140 kg/m2h) than PES membrane, due to an increase in pore size, porosity, and hydrophilicity. Moreover, the heavy metal ion removal capability of the resulting membranes significantly increased due to the formation of chelated metal ions at the surface of the PES/B-Cur membrane in the presence of B-Cur nanoparticles. The Fe2+, Cu2+, pb2+, Mn2+, Zn2+, and Ni2+ rejection measured 99.88, 98.72, 99.61, 99.31, 99.11, and 99.51% for PES membrane containing 0.5 wt% B-Cur nanoparticles whereas they were 15.13, 14.21, 16.43, 14.38, 15.11, and 14.98% for PES. The PES membrane containing 0.5 wt% B-Cur nanoparticles showed the maximum adsorption capacity of 35.01 mg/g (for Pb2+), 32.20 mg/g for (for Ni2+), 31.12 mg/g (for Cu2+), 29.08 mg/g (for Fe2+), 27.08 mg/g (for Zn2+), and 25.32 mg/g (for Mn2+). In addition, the PES/B-Cur0.5 showed higher permeate flux and FRR than other samples through the entire process of filtration. The reusability results for the PES/B-Cur0.5 exhibited a slight reduction in rejection of Fe2+, Cu2+, pb2+, Mn2+, Ni2+, and Zn2+ by only 14.5, 15.3, 13.5, 14.4, 15.1, and 14.0%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cej.2020.124546

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 181

Metadata

Authors
Moradi, G., Zinadini, S., Rajabi, L., & Ashraf Derakhshan, A.
Venue
Chemical Engineering Journal
Publisher
Elsevier BV
Published
2020-06
Volume
390
Pages
124546
ISSN
1385-8947 (ISSN-L)
OpenAlex
W3007829128
Cited by
181
References
2
FWCI
7.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Removal of heavy metal ions using a new high performance nanofiltration membrane modified with curcumin boehmite nanoparticles. https://app.cochat.ai/papers/10.1016/j.cej.2020.124546
The paper
Moradi, G., Zinadini, S., Rajabi, L., & Ashraf Derakhshan, A. (2020). Removal of heavy metal ions using a new high performance nanofiltration membrane modified with curcumin boehmite nanoparticles. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2020.124546

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.