The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Constructing stimuli-free self-healing, robust and ultrasensitive biocompatible hydrogel sensors with conductive cellulose nanocrystals
Abstract
Abstract Self-healing conductive hydrogels as artificial skin-like materials hold great potential applications in the fields of artificial intelligence, soft robotics and personal healthcare. However, it remained challenging to construct stimuli-free self-healing biomimetic hydrogels with ultra-stretchability and excellent sensitivity. Herein, polyaniline (PANI) was coated on the surface polycarboxylic multi-branched cellulose nanocrystals (Multi CNC-PANI) via templated polymerization. Afterword, rod-like Multi CNC-PANI served as a dynamic bridge endowed those hydrogels hierarchical structure and dynamic hydrogen bond interactions doped with polyvinyl alcohol (PVA)/borax system. Combined with the dynamic borate ester bonds, the biomimetic nanocomposite hydrogels had high breaking strength (171.52 KPa), ultra-stretchability (1085%), rapid self-healing properties, adhesiveness, decent biocompatibility, and sensitivity. Especially, the hydrogels could keep good self-healing ability both in air and underwater without any stimuli, and the self-healing efficiency could reach up to 99.56% within 120 s. This hydrogel sensor could sensitively detect and distinguish human motions including swallow, fingers, wrist, elbow and knee joints, in real-time. Besides, the self-healed hydrogel gave detective signal with uniform and repeatable sensitivity, which endowed the hydrogels mechanically adaptability and good store stability. Therefore, the strategy may provide unique opportunities in designing biomimetic sensors with skin-like mechanical stretchability, sensitivity and self-healing properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Cited by
Zhao, L., Ren, Z., Liu, X., Ling, Q., Li, Z., & Gu, H. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c01343 · Cited by 394
Cui, C., Fu, Q., Meng, L., Hao, S., Dai, R., & Yang, J. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00807 · Cited by 353
Pi, M., Qin, S., Wen, S., Wang, Z., Wang, X., Li, M., Lu, H., Meng, Q., Cui, W., & Ran, R. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202210188 · Cited by 282
Rana, A. K., Scarpa, F., & Thakur, V. K. (2022) · Industrial Crops and Products · doi:10.1016/j.indcrop.2022.115356 · Cited by 134
Metadata
- Authors
- Song, M., Yu, H., Zhu, J., Ouyang, Z., Abdalkarim, S. Y. H., Tam, K. C., & Li, Y.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2020-10
- Volume
- 398
- Pages
- 125547
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W3026334777
- Cited by
- 237
- References
- 1
- FWCI
- 10.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Constructing stimuli-free self-healing, robust and ultrasensitive biocompatible hydrogel sensors with conductive cellulose nanocrystals. https://app.cochat.ai/papers/10.1016/j.cej.2020.125547
- The paper
- Song, M., Yu, H., Zhu, J., Ouyang, Z., Abdalkarim, S. Y. H., Tam, K. C., & Li, Y. (2020). Constructing stimuli-free self-healing, robust and ultrasensitive biocompatible hydrogel sensors with conductive cellulose nanocrystals. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2020.125547
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.