Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 277

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Construction of durable flame-retardant and robust superhydrophobic coatings on cotton fabrics for water-oil separation application

Guo, Wenwen, Wang, Xin, Huang, Jiali, Zhou, Yifan, Cai, Wei, Wang, Junling, Song, Lei, Hu, Yuan · 2020 · Chemical Engineering Journal

Abstract

A flame-retardant and superhydrophobic coating was deposited on cotton fabrics using a simple two-step spraying method. In detailed, the first step involved flame-retardant layer consisted of alkylammonium functional silsesquioxane (A-POSS)/phytic acid (PA) complex, while the second step generated superhydrophobic layer that was composed of hierarchical structured titanium oxide@polydimethylsiloxane (TiO2@PDMS) composite. The influence of the components’ loading in the coating on flame-retardant, thermal and wetting properties of the coated cotton fabrics was investigated systematically. The optimized coated cotton sample denoted as C3-PDMS-TiO2 was screened through limiting oxygen index (LOI), UL-94 flammability test, cone calorimetry measurement and water contact angle (WCA). Specifically, C3-PDMS-TiO2 sample showed self-extinguishing behavior in the vertical burning test, as well as a significantly enhanced LOI to 29% from 18% for pristine cotton fabrics. Furthermore, the peak heat release rate (PHRR) and the total heat release (THR) values of C3-PDMS-TiO2 were significantly declined by 70% and 41%, respectively, compared to those of pristine cotton fabrics. Additionally, C3-PDMS-TiO2 exhibited super self-cleaning ability as a consequence of its superhydrophobic surface. Furthermore, C3-PDMS-TiO2 was applied for water-oil separation, and exhibited robust ability even in strong acid- or alkali-oil mixtures. The C3-PDMS-TiO2 fabrics also displayed super abrasion resistance (WCA > 139° after 50 abrasion cycles) and washing durability (self-extinguishing after 5 laundering cycles). This facile finishing technique has great potentials in application as multifunctional advanced textiles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cej.2020.125661

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Metadata

Authors
Guo, W., Wang, X., Huang, J., Zhou, Y., Cai, W., Wang, J., Song, L., & Hu, Y.
Venue
Chemical Engineering Journal
Publisher
Elsevier BV
Published
2020-10
Volume
398
Pages
125661
ISSN
1385-8947 (ISSN-L)
OpenAlex
W3032485974
Cited by
277
References
23
FWCI
14.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Construction of durable flame-retardant and robust superhydrophobic coatings on cotton fabrics for water-oil separation application. https://app.cochat.ai/papers/10.1016/j.cej.2020.125661
The paper
Guo, W., Wang, X., Huang, J., Zhou, Y., Cai, W., Wang, J., Song, L., & Hu, Y. (2020). Construction of durable flame-retardant and robust superhydrophobic coatings on cotton fabrics for water-oil separation application. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2020.125661

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.