Efficient moxifloxacin degradation by CoFe2O4 magnetic nanoparticles activated peroxymonosulfate: Kinetics, pathways and mechanisms
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Abstract CoFe2O4 magnetic nanoparticles (CoFe2O4 MNPs) were used as heterogeneous catalysts to activate peroxymonosulfate (PMS) for moxifloxacin (MOX) removal in this study. The impacts of initial pH, PMS, catalyst dosage, coexisting ions, and natural organic matter (NOM) were investigated, and the possible degradation pathways of MOX were proposed. The results indicated that efficient degradation of MOX (99.8%) could be achieved in the CoFe2O4/PMS system with the optimum reaction condition (initial pH = 9, CoFe2O4 dosage = 100 mg/L, PMS dosage = 0.25 mM, reaction time = 30 min, and MOX concentration = 5 mg/L). The rule of MOX degradation followed the pseudo-first order kinetic reaction equation (kobs = 0.194 min−1). According to the results of radical scavenging experiments, the contribution of HO• on MOX removal was negligible, and SO4•− played a dominant role in MOX degradation. Five probable MOX degradation pathways were proposed based on the identified fifteen degradation intermediates, including defluorination, decarboxylation, decyclopropyl reaction, transformation of quinolone moieties, oxidation, and cleavage of nitrogen-containing heterocycle. The existence of 5 mM Cl-, HCO3−, and HA posed stronger negative effects on MOX removal. However, the MOX removal efficiency increased with H2PO4- concentration in the first 15 min. The removal efficiency of MOX decreased significantly in the CoFe2O4/PMS system when the catalyst was reused five times. These research conclusions could provide useful information for the practical application of CoFe2O4/PMS system in wastewater treatment of antibiotics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antibiotics in the aquatic environment – A review – Part I
Kümmerer, K. (2009) · Chemosphere · doi:10.1016/j.chemosphere.2008.11.086 · Cited by 4,475
Hu, P., & Long, M. (2016) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2015.07.024 · Cited by 2,184
Michael, I., Rizzo, L., McArdell, C. S., Manaia, C. M., Merlin, C., Schwartz, T., Dagot, C., & Fatta-Kassinos, D. (2013) · Water Research · doi:10.1016/j.watres.2012.11.027 · Cited by 2,013
Influence of pH on the Formation of Sulfate and Hydroxyl Radicals in the UV/Peroxymonosulfate System
Guan, Y.-H., Ma, J., Li, X.-C., Fang, J.-Y., & Chen, L.-W. (2011) · Environmental Science & Technology · doi:10.1021/es2017363 · Cited by 1,338
Advanced oxidation process-mediated removal of pharmaceuticals from water: A review
Kanakaraju, D., Glass, B. D., & Oelgemöller, M. (2018) · Journal of Environmental Management · doi:10.1016/j.jenvman.2018.04.103 · Cited by 1,180
Ren, Y., Lin, L., Ma, J., Yang, J., Feng, J., & Fan, Z. (2015) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2014.10.051 · Cited by 1,121
Influence of pH on persulfate oxidation of TCE at ambient temperatures
Liang, C., Wang, Z.-S., & Bruell, C. J. (2007) · Chemosphere · doi:10.1016/j.chemosphere.2006.05.026 · Cited by 796
Li, J., Xu, M., Yao, G., & Lai, B. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.05.032 · Cited by 739
Duan, X., Ao, Z., Zhou, L., Sun, H., Wang, G., & Wang, S. (2016) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2016.01.059 · Cited by 739
Self-citationXu, Y., Ai, J., & Zhang, H. (2016) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2016.01.023 · Cited by 683
Cited by
Dong, Z.-T., Niu, C.-G., Guo, H., Niu, H.-Y., Liang, S., Liang, C., Liu, H.-Y., & Yang, Y.-Y. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.130850 · Cited by 198
Zhang, X., Wei, J., Wang, C., Wang, L., Guo, Z., & Song, Y. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.150514 · Cited by 179
Metadata
- Authors
- Liu, L., Mi, H., Zhang, M., Sun, F., Zhan, R., Zhao, H., He, S., & Zhou, L.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2021-03
- Volume
- 407
- Pages
- 127201
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W3090667105
- Cited by
- 180
- References
- 48
- FWCI
- 6.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.