The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Mxene (Ti3C2T )/cellulose nanofiber/porous carbon film as free-standing electrode for ultrathin and flexible supercapacitors
Abstract
Abstract Traditional porous carbon (PC)-based supercapacitors (SCs) are generally stiff and heavy owing to their rigid components and bulky additives, such as binders, conducting materials, and current collectors. Herein, a porous (574.5 m2 g−1), conductive (83.1 S cm−1), and flexible MXene (Ti3C2Tx)/cellulose nanofiber (CNF)/PC hybrid film is prepared by strong interfacial interactions among its components via a facile vacuum-filtration method. Three-dimensional PC provides abundant micropores for charge storage and considerable amount of meso/macropores for fast diffusion of ions. Two-dimensional Ti3C2Tx offers a significantly high conductivity of 2.6 × 103 S cm−1 and a good film-forming ability. A one-dimensional CNF ensures high mechanical properties with a tensile strength of 38.6 MPa for the hybrid film by binding the adjacent Ti3C2Tx flakes and PC. Additionally, the presence of CNF and PC increases the interlayer distance between Ti3C2Tx flakes, thereby providing more ion-accessible surface areas on Ti3C2Tx and creating open gaps for fast ion transport. Benefiting from these electrochemically attractive properties, this film is further employed as a free-standing electrode to fabricate a high-performance quasi-solid-state SC, which demonstrates an ultrathin thickness of 0.2 mm, a high flexibility, a significantly high areal capacitance of 143 mF cm−2 at 0.1 mA cm−2, and a large areal energy density of 2.4 μWh cm−2 at 17.5 μW cm−2, with a high retention of ~50% even after increasing the power density by ~100 fold. This work will pave the way for developing free-standing MXene-based hybrid films that simultaneously possess excellent conductivity, good mechanical properties, and large charge storage capacity for flexible and high-performance SCs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hou, J., Cao, C., Idrees, F., & Ma, X. (2015) · ACS Nano · doi:10.1021/nn506394r · Cited by 1,529
Highly Self-Healable 3D Microsupercapacitor with MXene–Graphene Composite Aerogel
Yue, Y., Liu, N., Ma, Y., Wang, S., Liu, W., Luo, C., Zhang, H., Cheng, F., Rao, J., Hu, X., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07528 · Cited by 736
Cited by
Panda, S., Deshmukh, K., Khadheer Pasha, S. K., Theerthagiri, J., Manickam, S., & Choi, M. Y. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2022.214518 · Cited by 465
Baig, N. (2023) · Composites Part A: Applied Science and Manufacturing · doi:10.1016/j.compositesa.2022.107362 · Cited by 450
Xu, T., Song, Q., Liu, K., Liu, H., Pan, J., Liu, W., Dai, L., Zhang, M., Wang, Y., Si, C., et al. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01073-x · Cited by 435
Luo, L., Lan, Y., Zhang, Q., Deng, J., Luo, L., Zeng, Q., Gao, H., & Zhao, W. (2022) · Journal of Energy Storage · doi:10.1016/j.est.2022.105839 · Cited by 255
Metadata
- Authors
- Chen, W., Zhang, D., Yang, K., Luo, M., Yang, P., & Zhou, X.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2021-06
- Volume
- 413
- Pages
- 127524
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W3097089160
- Cited by
- 214
- References
- 2
- FWCI
- 19.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.