The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Angiotensin Analogs with Divergent Bias Stabilize Distinct Receptor Conformations
Open accessAbstract
Summary “Biased” G protein-coupled receptor (GPCR) agonists preferentially activate pathways mediated by G proteins or β-arrestins. Here we use double electron-electron resonance spectroscopy to probe the changes that ligands induce in the conformational distribution of the angiotensin II type I receptor. Monitoring distances between ten pairs of nitroxide labels distributed across the intracellular regions enabled mapping of four underlying sets of conformations. Ligands from different functional classes have distinct, characteristic effects on the conformational heterogeneity of the receptor. Compared to angiotensin II, the endogenous agonist, agonists with enhanced Gq coupling more strongly stabilize an “open” conformation with an accessible transducer-binding site. β-Arrestin-biased agonists deficient in Gq coupling do not stabilize this open conformation but instead favor two more occluded conformations. These data suggest a structural mechanism for biased ligand action at the angiotensin receptor that can be exploited to rationally design GPCR-targeting drugs with greater specificity of action.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
VMD: visual molecular dynamics
Humphrey, W., Dalke, A., & Schulten, K. (1996) · Journal of Molecular Graphics · doi:10.1016/0263-7855(96)00018-5 · Cited by 66,952
Paatero, P., & Tapper, U. (1994) · Environmetrics · doi:10.1002/env.3170050203 · Cited by 6,023
Update of the CHARMM All-Atom Additive Force Field for Lipids: Validation on Six Lipid Types
Klauda, J. B., Venable, R. M., Freites, J. A., O’Connor, J. W., Tobias, D. J., Mondragon-Ramirez, C., Vorobyov, I., MacKerell, A. D., & Pastor, R. W. (2010) · The Journal of Physical Chemistry B · doi:10.1021/jp101759q · Cited by 4,501
CHARMM36 all-atom additive protein force field: Validation based on comparison to NMR data
Huang, J., & MacKerell, A. D. (2013) · Journal of Computational Chemistry · doi:10.1002/jcc.23354 · Cited by 4,430
Salomon-Ferrer, R., Götz, A. W., Poole, D., Le Grand, S., & Walker, R. C. (2013) · Journal of Chemical Theory and Computation · doi:10.1021/ct400314y · Cited by 3,372
SwissParam: A fast force field generation tool for small organic molecules
Zoete, V., Cuendet, M. A., Grosdidier, A., & Michielin, O. (2011) · Journal of Computational Chemistry · doi:10.1002/jcc.21816 · Cited by 2,370
Automation of the CHARMM General Force Field (CGenFF) I: Bond Perception and Atom Typing
Vanommeslaeghe, K., & MacKerell, A. D. (2012) · Journal of Chemical Information and Modeling · doi:10.1021/ci300363c · Cited by 2,169
Long-Time-Step Molecular Dynamics through Hydrogen Mass Repartitioning
Hopkins, C. W., Le Grand, S., Walker, R. C., & Roitberg, A. E. (2015) · Journal of Chemical Theory and Computation · doi:10.1021/ct5010406 · Cited by 1,355
OPM: Orientations of Proteins in Membranes database
Lomize, M. A., Lomize, A. L., Pogozheva, I. D., & Mosberg, H. I. (2006) · Bioinformatics · doi:10.1093/bioinformatics/btk023 · Cited by 1,173
DEER Distance Measurements on Proteins
Jeschke, G. (2012) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-032511-143716 · Cited by 973
Cited by
Common activation mechanism of class A GPCRs
Zhou, Q., Yang, D., Wu, M., Guo, Y., Guo, W., Zhong, L., Cai, X., Dai, A., Jang, W., Shakhnovich, E. I., et al. (2019) · eLife · doi:10.7554/elife.50279 · Cited by 632
Bringing Molecular Dynamics Simulation Data into View
Hildebrand, P. W., Rose, A. S., & Tiemann, J. K. S. (2019) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2019.06.004 · Cited by 298
Molecular basis of β-arrestin coupling to formoterol-bound β1-adrenoceptor
Lee, Y., Warne, T., Nehmé, R., Pandey, S., Dwivedi-Agnihotri, H., Chaturvedi, M., Edwards, P. C., García-Nafría, J., Leslie, A. G. W., Shukla, A. K., et al. (2020) · Nature · doi:10.1038/s41586-020-2419-1 · Cited by 295
Advances in therapeutic peptides targeting G protein-coupled receptors
Davenport, A. P., Scully, C. C. G., de Graaf, C., Brown, A. J. H., & Maguire, J. J. (2020) · Nature Reviews Drug Discovery · doi:10.1038/s41573-020-0062-z · Cited by 275
Molecular recognition of morphine and fentanyl by the human μ-opioid receptor
Zhuang, Y., Wang, Y., He, B., He, X., Zhou, X. E., Guo, S., Rao, Q., Yang, J., Liu, J., Zhou, Q., et al. (2022) · Cell · doi:10.1016/j.cell.2022.09.041 · Cited by 273
Metadata
- Authors
- Wingler, L. M., Elgeti, M., Hilger, D., Latorraca, N. R., Lerch, M. T., Staus, D. P., Dror, R. O., Kobilka, B. K., Hubbell, W. L., & Lefkowitz, R. J.
- Venue
- Cell
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 176
- Issue
- 3
- Pages
- 468-478.e11
- ISSN
- 0092-8674 (ISSN-L)
- OpenAlex
- W2910817182
- Cited by
- 272
- References
- 63
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Angiotensin Analogs with Divergent Bias Stabilize Distinct Receptor Conformations. https://app.cochat.ai/papers/10.1016/j.cell.2018.12.005
- The paper
- Wingler, L. M., Elgeti, M., Hilger, D., Latorraca, N. R., Lerch, M. T., Staus, D. P., Dror, R. O., Kobilka, B. K., Hubbell, W. L., & Lefkowitz, R. J. (2019). Angiotensin Analogs with Divergent Bias Stabilize Distinct Receptor Conformations. Cell. https://doi.org/10.1016/j.cell.2018.12.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.