Performance-based design and carbonation of concrete with high fly ash content
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper reports on an investigation of the durability of high-volume fly ash concrete exposed to carbonation (XC class in EN 206-1 Standard). The reduction of cement content is assumed to mitigate CO2 emissions due to the production of Portland cement clinker. The durability of concrete is assessed through a performance-based approach. First, a performance-based method was applied to design a concrete mixture with more than 50% substitution of cement by fly ash. To cope with the high viscosity of the so-obtained mixture, an air-entraining agent was used. Due to its low cement content, the so-obtained mixture does not comply with the prescriptive requirements of the European standard (EN 206-1). Thus, according to the equivalent performance concept, its potential durability has to be proved through comparison with reference mixtures complying with prescriptive standard requirements. The performance-based evaluation of the durability of the designed mixture and reference mixtures (with Portland cement and blended cement) consisted in porosity and accelerated carbonation tests. The influence of curing mode and thermal treatment duration before carbonation test were also investigated. Whatever the curing mode, the designed mixture was found as resistant to accelerated carbonation as the reference mixture containing blended cement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thiery, M., Villain, G., Dangla, P., & Platret, G. (2007) · Cement and Concrete Research · doi:10.1016/j.cemconres.2007.04.002 · Cited by 755 · cited 2×
“Thus the diffusion of CO2 is affected by the liquid water saturation degree: the drier the porosity, the higher the diffusion [24].”
BackgroundPapadakis, V. G. (2000) · Cement and Concrete Research · doi:10.1016/s0008-8846(99)00249-5 · Cited by 713 · cited 1×
“Moreover, the CH content is likely to be reduced by the pozzolanic reactions due to fly ash, but this has not been confirmed in experimental studies [28,29].”
Background
Cited by
Carbonation of cement-based materials: Challenges and opportunities
Ashraf, W. (2016) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2016.05.080 · Cited by 657
de Brito, J., & Kurda, R. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.123558 · Cited by 436
A brief on high-volume Class F fly ash as cement replacement – A guide for Civil Engineer
Rashad, A. M. (2015) · International Journal of Sustainable Built Environment · doi:10.1016/j.ijsbe.2015.10.002 · Cited by 291
Pacheco Torgal, F., Miraldo, S., Labrincha, J. A., & De Brito, J. (2012) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2012.04.066 · Cited by 239
“[12] when fly-ash concrete mixes are stored 28 days under water before testing (water-curing), similar carbonation depths were measured for the two mixes (30% and 50% fly-ash), also whatever the prior oven-drying period.”
BackgroundMethodLiu, W., Li, Y., Lin, S., Tang, L., Dong, Z., Xing, F., Dong, B., & Hong, S. (2020) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2020.119598 · Cited by 52
Bernal, S. A., Dhandapani, Y., Elakneswaran, Y., Gluth, G. J. G., Gruyaert, E., Juenger, M. C. G., Lothenbach, B., Olonade, K. A., Sakoparnig, M., Shi, Z., et al. (2024) · Materials and Structures · doi:10.1617/s11527-024-02424-9 · Cited by 35
Metadata
- Authors
- Younsi, A., Turcry, P., Rozière, E., Aït-Mokhtar, A., & Loukili, A.
- Venue
- Cement and Concrete Composites
- Publisher
- Elsevier BV
- Published
- 2011-11
- Volume
- 33
- Issue
- 10
- Pages
- 993-1000
- ISSN
- 0958-9465 (ISSN-L)
- OpenAlex
- W2049476569
- Cited by
- 136
- References
- 2
- FWCI
- 16.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.