Energy dissipation characteristics of all-grade polyethylene fiber-reinforced engineered cementitious composites (PE-ECC)
Open accessThe DOI matches its Crossref record.
Abstract
Systematical research was implemented to explore the impacts of fiber reinforcement index VfLf/df (i.e., the product of fiber volume Vf and fiber aspect ratio Lf/df) on the energy dissipation characteristics including strain energy density and fracture energy, of polyethylene fiber-reinforced engineered cementitious composites (PE-ECC) with compressive strength varying from normal to high. Six VfLf/df values (i.e., 5, 7.5, 9, 10, 15, and 18) and five water/binder ratios (i.e., 0.14, 0.16, 0.18, 0.22, and 0.32) were considered in total. Strain energy density and fracture energy reflect the crack resistance capacity during the strain-hardening and softening processes of PE-ECC, respectively. The strain energy density of PE-ECC increased significantly with the increase of VfLf/df and the decrease of water/binder ratio. The fracture energy increased noticeably with the growth of VfLf/df, while it attained the maximum value at the water/binder ratio of 0.16. For ECC including both the strain-hardening and softening processes, neither the strain energy density nor fracture energy alone can reflect its crack resistance capacity and energy dissipation capacity comprehensively. Thus, in the design and simulation processes of ECC, both energy parameters need to be considered in the constitutive model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guo, P., Meng, W., Xu, M., Li, V. C., & Bao, Y. (2021) · Materials · doi:10.3390/ma14123143 · Cited by 114
Metadata
- Authors
- Yu, K., Ding, Y., Liu, J., & Bai, Y.
- Venue
- Cement and Concrete Composites
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 106
- Pages
- 103459
- ISSN
- 0958-9465 (ISSN-L)
- OpenAlex
- W2987275143
- Cited by
- 177
- References
- 0
- FWCI
- 12.52
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.