Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 178

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Capturing CO2 from ambient air using a polyethyleneimine–silica adsorbent in fluidized beds

Open access
Zhang, Wenbin, Liu, Hao, Sun, Chenggong, Drage, Trevor C., Snape, Colin E.·2014·Chemical Engineering Science

Abstract

Carbon Capture and Storage (CCS) uses a combination of technologies to capture, transport and store carbon dioxide (CO2) emissions from large point sources such as coal or natural gas-fired power plants. Capturing CO2 from ambient air has been considered as a carbon-negative technology to mitigate anthropogenic CO2 emissions in the air. The performance of a mesoporous silica-supported polyethyleneimine (PEI)–silica adsorbent for CO2 capture from ambient air has been evaluated in a laboratory-scale Bubbling Fluidized Bed (BFB) reactor. The air capture tests lasted for between 4 and 14 days using 1 kg of the PEI–silica adsorbent in the BFB reactor. Despite the low CO2 concentration in ambient air, nearly 100% CO2 capture efficiency has been achieved with a relatively short gas–solid contact time of 7.5 s. The equilibrium CO2 adsorption capacity for air capture was found to be as high as 7.3 wt%, which is amongst the highest values reported to date. A conceptual design is completed to evaluate the technological and economic feasibility of using PEI–silica adsorbent to capture CO2 from ambient air at a large scale of capturing 1 Mt-CO2 per year. The proposed novel “PEI-CFB air capture system” mainly comprises a Circulating Fluidized Bed (CFB) adsorber and a BFB desorber with a CO2 capture capacity of 40 t-CO2/day. Large pressure drop is required to drive the air through the CFB adsorber and also to suspend and circulate the solid adsorbents within the loop, resulting in higher electricity demand than other reported air capture systems. However, the Temperature Swing Adsorption (TSA) technology adopted for the regeneration strategy in the separate BFB desorber has resulted in much smaller thermal energy requirement. The total energy required is 6.6 GJ/t-CO2 which is comparable to other reference air capture systems. By projecting a future scenario where decarbonization of large point energy sources has been largely implemented by integration of CCS technologies, the operating cost under this scenario is estimated to be $108/t-CO2 captured and $152/t-CO2 avoided with an avoided fraction of 0.71. Further research on the proposed 40 t-CO2/day ‘PEI-CFB Air Capture System’ is still needed which should include the evaluation of the capital costs and the experimental investigation of air capture using a laboratory-scale CFB system with the PEI–silica adsorbent.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ces.2014.05.018

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 178

Metadata

Authors
Zhang, W., Liu, H., Sun, C., Drage, T. C., & Snape, C. E.
Venue
Chemical Engineering Science
Publisher
Elsevier BV
Published
2014-09
Volume
116
Pages
306-316
ISSN
0009-2509 (ISSN-L)
OpenAlex
W2034781104
Cited by
178
References
2
FWCI
19.48
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Capturing CO2 from ambient air using a polyethyleneimine–silica adsorbent in fluidized beds. https://app.cochat.ai/papers/10.1016/j.ces.2014.05.018
The paper
Zhang, W., Liu, H., Sun, C., Drage, T. C., & Snape, C. E. (2014). Capturing CO2 from ambient air using a polyethyleneimine–silica adsorbent in fluidized beds. Chemical Engineering Science. https://doi.org/10.1016/j.ces.2014.05.018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.