The DOI matches its Crossref record; 121 of the 121 references it cites were found in a registry or an index.
A review on microreactors: Reactor fabrication, design, and cutting-edge applications
Abstract
Abstract This review focuses on the latest trends and advancements in microstructured reactors. With the recent drive towards the production of miniaturized systems, microstructured reactors have gained significant prominence in the chemical and process industries. Herein, we describe the fabrication, commercial aspects, design principles, and cutting-edge applications of microreactors. An overview of the significant areas of application under broad categories such as biological and pharmaceutical applications, inorganic and noble metal nanoparticles, and organic chemicals and polymers is also included. Finally, the article discusses future research prospects and key issues on microstructured reactors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Jivani, R. R., Lakhtaria, G. J., Patadiya, D. D., Patel, L. D., Jivani, N. P., & Jhala, B. P. (2013) · Saudi Pharmaceutical Journal · doi:10.1016/j.jsps.2013.12.003 · Cited by 34
RetractedComputational Methods for Fluid Dynamics
Ferziger, J. H., & Perić, M. (2002) · Springer eBooks · doi:10.1007/978-3-642-56026-2 · Cited by 3,745
Fundamentals of Microfabrication
Madou, M. J. (2018) · CRC Press eBooks · doi:10.1201/9781482274004 · Cited by 2,020
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Ullmann's encyclopedia of industrial chemistry
Peters, A. T. (1988) · Dyes and Pigments · doi:10.1016/0143-7208(88)80015-9 · Cited by 1,751
Cambié, D., Bottecchia, C., Straathof, N. J. W., Hessel, V., & Noël, T. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00707 · Cited by 1,502
The greener synthesis of nanoparticles
Kharissova, O. V., Dias, H. V. R., Kharisov, B. I., Pérez, B. O., & Pérez, V. M. J. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.01.003 · Cited by 1,362
The past, present and potential for microfluidic reactor technology in chemical synthesis
Elvira, K. S., i Solvas, X. C., Wootton, R. C. R., & deMello, A. J. (2013) · Nature Chemistry · doi:10.1038/nchem.1753 · Cited by 1,203
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
Colloidal nanoparticles as advanced biological sensors
Howes, P. D., Chandrawati, R., & Stevens, M. M. (2014) · Science · doi:10.1126/science.1247390 · Cited by 1,024
Cited by
Dong, G., Chen, B., Liu, B., Hounjet, L. J., Cao, Y., Stoyanov, S. R., Yang, M., & Zhang, B. (2022) · Water Research · doi:10.1016/j.watres.2022.118047 · Cited by 303
Masui, H., & Fuse, S. (2022) · Organic Process Research & Development · doi:10.1021/acs.oprd.2c00074 · Cited by 38
Metadata
- Authors
- Suryawanshi, P. L., Gumfekar, S. P., Bhanvase, B. A., Sonawane, S. H., & Pimplapure, M. S.
- Venue
- Chemical Engineering Science
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 189
- Pages
- 431-448
- ISSN
- 0009-2509 (ISSN-L)
- OpenAlex
- W2793362770
- Cited by
- 305
- References
- 121
- FWCI
- 11.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A review on microreactors: Reactor fabrication, design, and cutting-edge applications. https://app.cochat.ai/papers/10.1016/j.ces.2018.03.026
- The paper
- Suryawanshi, P. L., Gumfekar, S. P., Bhanvase, B. A., Sonawane, S. H., & Pimplapure, M. S. (2018). A review on microreactors: Reactor fabrication, design, and cutting-edge applications. Chemical Engineering Science. https://doi.org/10.1016/j.ces.2018.03.026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.