Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 166

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

The Stool DNA Test Is More Accurate Than the Plasma Septin 9 Test in Detecting Colorectal Neoplasia

Open access
Ahlquist, David A., Taylor, William R., Mahoney, Douglas W., Zou, Hongzhi, Domanico, Michael, Thibodeau, Stephen N., Boardman, Lisa A., Berger, Barry M., Lidgard, Graham P. · 2012 · Clinical Gastroenterology and Hepatology

Abstract

Background & Aims Several noninvasive tests have been developed for colorectal cancer (CRC) screening. We compared the sensitivities of a multi-marker test for stool DNA (sDNA) and a plasma test for methylated Septin 9 (SEPT9) in identifying patients with large adenomas or CRC. Methods We analyzed paired stool and plasma samples from 30 patients with CRC and 22 with large adenomas from Mayo Clinic archives. Stool (n=46) and plasma (n=49) samples from age- and sex-matched patients with normal colonoscopy results were used as controls. The sDNA test is an assay for methylated BMP3, NDRG4, vimentin, and TFPI2; mutant KRAS; the β-actin gene, and quantity of hemoglobin (by the porphyrin method). It was performed blindly at Exact Sciences (Madison WI); the test for SEPT9 was performed at ARUP Laboratories (Salt Lake City UT). Results were considered positive based on the manufacturer's specificity cutoff values of 90% and 89%, respectively. Results The sDNA test detected adenomas (median 2 cm, range 1–5 cm) with 82% sensitivity (95% confidence interval [CI], 60%–95%); SEPT9 had 14% sensitivity (95% CI, 3%–35%; P=.0001). The sDNA test identified patients with CRC with 87% sensitivity (95% CI, 69%–96%); SEPT9 had 60% sensitivity (95% CI, 41%–77%; P=.046). The sDNA test identified patients with stage I–III CRC with 91% sensitivity (95% CI, 71%–99%); SEPT9 had 50% sensitivity (95% CI, 28%–72%; P=.013); for stage IV CRC, sensitivity values were 75% (95% CI, 35%–97%) and 88% (95% CI, 47%–100%), respectively (P=.56). False-positive rates were 7% for the sDNA test and 27% for SEPT9. Conclusions Based on analyses of paired samples, the sDNA test detects non-metastatic CRC and large adenomas with significantly greater levels of sensitivity than the SEPT9 test. These findings might be used to modify approaches for CRC prevention and early detection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cgh.2011.10.008

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 166

Metadata

Authors
Ahlquist, D. A., Taylor, W. R., Mahoney, D. W., Zou, H., Domanico, M., Thibodeau, S. N., Boardman, L. A., Berger, B. M., & Lidgard, G. P.
Venue
Clinical Gastroenterology and Hepatology
Publisher
Elsevier BV
Published
2012-03
Volume
10
Issue
3
Pages
272-277.e1
ISSN
1542-3565 (ISSN-L)
OpenAlex
W2060650722
Cited by
166
References
2
FWCI
6.07
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Stool DNA Test Is More Accurate Than the Plasma Septin 9 Test in Detecting Colorectal Neoplasia. https://app.cochat.ai/papers/10.1016/j.cgh.2011.10.008
The paper
Ahlquist, D. A., Taylor, W. R., Mahoney, D. W., Zou, H., Domanico, M., Thibodeau, S. N., Boardman, L. A., Berger, B. M., & Lidgard, G. P. (2012). The Stool DNA Test Is More Accurate Than the Plasma Septin 9 Test in Detecting Colorectal Neoplasia. Clinical Gastroenterology and Hepatology. https://doi.org/10.1016/j.cgh.2011.10.008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.