Prospective, Same-Day, Direct Comparison of Controlled Attenuation Parameter With the M vs the XL Probe in Patients With Nonalcoholic Fatty Liver Disease, Using Magnetic Resonance Imaging–Proton Density Fat Fraction as the Standard
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND & AIMS: Controlled attenuation parameter (CAP) measurements using M probe have been reported to be lower than those of the XL-probe in detection of hepatic steatosis. However, there has been no direct comparison of CAP with the M vs the XL probe in patients with nonalcoholic fatty liver disease (NAFLD). We compared CAP with the M vs the XL probe for quantification of hepatic fat content, using magnetic resonance imaging proton density fat fraction (MRI-PDFF) as the standard. METHODS: We performed a prospective study of 100 adults (mean body mass index [BMI], 30.6 ± 4.7 kg/m2) with and without NAFLD, assessed by CAP with the M probe and XL probe on the same day, at a single research center, from November 2017 through November 2018. We then measured the MRI-PDFF as the reference standard. Outcomes were presence of hepatic steatosis, defined as MRI-PDFF ≥ 5%, and detection of hepatic fat content ≥ 10%, defined as MRI-PDFF ≥ 10%. We performed area under the receiver operating characteristic curve (AUROC) analyses to assess the diagnostic accuracy of CAP for each probe in detection of hepatic steatosis (MRI-PDFF ≥ 5%) and of hepatic fat content ≥ 10%. RESULTS: Of the study participants, 68% had an MRI-PDFF of 5% or more and 48% had an MRI-PDFF of 10% or more. The mean CAP measured by the M probe (310 ± 62 db/m) was significantly lower than by the X probe (317 ± 63 db/m) (P = −007). When M probe was used in participants with BMIs <30 kg/ m2 and XL probe in participants with BMIs ≥30 kg/m2, the CAP measured by the M probe (312 ± 51.4 db/m) remained significantly lower than that of the XL probe (345 ± 47.6 db/m) (P =−0035.), when the MRI-PDFF was above 5%. The optimal threshold of CAP for the detection of MRI-PDFF≥5%, was 294 db/mwith the M probe and 307 db/mwith the XL probe. The optimal threshold of CAP for the detection of MRI-PDFF ≥ 10%, was 311 db/m with the M probe and 322 db/m with the XL probe. For only the XL probe, CAP measurements with an interquartile range below 30 dB/m detected an MRI-PDFF≥5% with a lower AUROC (0.97; 95% CI, 0.80–1.00) than CAP measurements with an interquartile range above 30 dB/m (AUROC, 0.82; 95% CI, 0.71–0.90) (P = .0129). CONCLUSIONS: In an analysis of the same patients using CAP with the M probe and XL probe, with MRI-PDFF as the standard, we found that the M probe under-quantifies CAP values compared with the XL probe, independent of BMI. The type of probe should be considered when interpreting CAP data from patients with NAFLD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noureddin, M., Lam, J., Peterson, M. R., Middleton, M., Hamilton, G., Le, T.-A., Bettencourt, R., Changchien, C., Brenner, D. A., Sirlin, C., et al. (2013) · Hepatology · doi:10.1002/hep.26455 · Cited by 550
Self-citationA Gut Microbiome Signature for Cirrhosis Due to Nonalcoholic Fatty Liver Disease
Caussy, C., Tripathi, A., Humphrey, G., Bassirian, S., Singh, S., Faulkner, C., Bettencourt, R., Rizo, E., Richards, L., Xu, Z. Z., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09455-9 · Cited by 338
Self-citation
Cited by
Petroff, D., Blank, V., Newsome, P. N., Shalimar, Voican, C. S., Thiele, M., de Lédinghen, V., Baumeler, S., Chan, W. K., Perlemuter, G., et al. (2021) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(20)30357-5 · Cited by 268
Jang, W., & Song, J. S. (2023) · Diagnostics · doi:10.3390/diagnostics13111852 · Cited by 55
Non-invasive diagnosis and staging of non-alcoholic fatty liver disease
Kechagias, S., Ekstedt, M., Simonsson, C., & Nasr, P. (2022) · Hormones · doi:10.1007/s42000-022-00377-8 · Cited by 39
Loomba, R., Daniel, P. C.-Y. N., Amangurbanova, M., Bettencourt, R., Madamba, E., Siddiqi, H., Richards, L., Gottwald, M. D., Feng, S., Margalit, M., et al. (2026) · Hepatology · doi:10.1097/hep.0000000000001396 · Cited by 17
Self-citation
Metadata
- Authors
- Caussy, C., Brissot, J., Singh, S., Bassirian, S., Hernandez, C., Bettencourt, R., Rizo, E., Richards, L., Sirlin, C. B., & Loomba, R.
- Venue
- Clinical Gastroenterology and Hepatology
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 18
- Issue
- 8
- Pages
- 1842-1850.e6
- ISSN
- 1542-3565 (ISSN-L)
- OpenAlex
- W2994810204
- Cited by
- 65
- References
- 2
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prospective, Same-Day, Direct Comparison of Controlled Attenuation Parameter With the M vs the XL Probe in Patients With Nonalcoholic Fatty Liver Disease, Using Magnetic Resonance Imaging–Proton Density Fat Fraction as the Standard. https://app.cochat.ai/papers/10.1016/j.cgh.2019.11.060
- The paper
- Caussy, C., Brissot, J., Singh, S., Bassirian, S., Hernandez, C., Bettencourt, R., Rizo, E., Richards, L., Sirlin, C. B., & Loomba, R. (2020). Prospective, Same-Day, Direct Comparison of Controlled Attenuation Parameter With the M vs the XL Probe in Patients With Nonalcoholic Fatty Liver Disease, Using Magnetic Resonance Imaging–Proton Density Fat Fraction as the Standard. Clinical Gastroenterology and Hepatology. https://doi.org/10.1016/j.cgh.2019.11.060
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.