CoChat

Sensitivity and Safety of Electromagnetic Navigation Bronchoscopy for Lung Cancer Diagnosis

Folch, Erik E., Labarca, Gonzalo, Ospina-Delgado, Daniel, Kheir, Fayez, Majid, Adnan, Khandhar, Sandeep J., Mehta, Hiren J., Jantz, Michael A., Fernandez-Bussy, Sebastian · 2020 · Chest
Cited by 174

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

BACKGROUND Bronchoscopy is a useful tool for the diagnosis of lesions near central airways; however, the diagnostic accuracy of these procedures for peripheral pulmonary lesions (PPL) is a matter of ongoing debate. In this setting, electromagnetic navigation bronchoscopy (ENB) is a technique utilized to navigate and obtain samples from these lesions. This systematic review and meta-analysis aims to explore the sensitivity of ENB in patients with PPL suspected of lung cancer. METHODS A comprehensive search of several databases was performed. Extracted data included sensitivity of ENB for malignancy, adequacy of the tissue sample, and complications. The study quality was assessed using the QUADAS-2 tool, and the combined data was meta-analyzed using a bivariate method model. A summary receiving operating curve (sROC) was created. Finally, the quality of evidence was rated using the GRADE approach. RESULTS Forty studies with a total of 3,342 participants were included in our analysis. ENB reported a pooled sensitivity of 77% (95% CI, 72 - 82%), I2= 80.6%; and specificity of 100% (CI, 99 - 100%), I2= 0% for malignancy. The sROC showed an area under the curve of 0.955, p=0.03. ENB achieved a sufficient sample for ancillary tests in 90.9% (84.8 - 96.9%), I2=80.7%. Risk of pneumothorax was 2.0% (95% CI, 1.0-3.0), I2=45.2%. We found subgroup differences according to the risk of bias and the number of sampling techniques. Meta-regression showed an association between sensitivity, and the mean distance of the sensor tip to the center of the nodule, the number of tissue sampling techniques, and the cancer prevalence in the study. CONCLUSION ENB is very safe with good sensitivity for diagnosing malignancy in patients with PPL. The applicability of our findings is limited as the majority of studies were done with the superDimension navigation system and heterogeneity was high. PROSPERO CRD42019109449.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.chest.2020.05.534

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 174

Metadata

Authors
Folch, E. E., Labarca, G., Ospina-Delgado, D., Kheir, F., Majid, A., Khandhar, S. J., Mehta, H. J., Jantz, M. A., & Fernandez-Bussy, S.
Venue
Chest
Publisher
Elsevier BV
Published
2020-10
Volume
158
Issue
4
Pages
1753-1769
ISSN
0012-3692 (ISSN-L)
OpenAlex
W3027088329
Cited by
174
References
9
FWCI
12.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensitivity and Safety of Electromagnetic Navigation Bronchoscopy for Lung Cancer Diagnosis. https://app.cochat.ai/papers/10.1016/j.chest.2020.05.534
The paper
Folch, E. E., Labarca, G., Ospina-Delgado, D., Kheir, F., Majid, A., Khandhar, S. J., Mehta, H. J., Jantz, M. A., & Fernandez-Bussy, S. (2020). Sensitivity and Safety of Electromagnetic Navigation Bronchoscopy for Lung Cancer Diagnosis. Chest. https://doi.org/10.1016/j.chest.2020.05.534

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.