The DOI matches its Crossref record; 104 of the 104 references it cites were found in a registry or an index.
Liquid-phase microextraction with porous hollow fibers, a miniaturized and highly flexible format for liquid–liquid extraction
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solid phase microextraction with thermal desorption using fused silica optical fibers
Arthur, C. L., & Pawliszyn, J. (1990) · Analytical Chemistry · doi:10.1021/ac00218a019 · Cited by 4,997
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Pedersen-Bjergaard, S., & Rasmussen, K. E. (1999) · Analytical Chemistry · doi:10.1021/ac990055n · Cited by 1,245
Self-citationAnalytical Chemistry in a Drop. Solvent Extraction in a Microdrop
Liu, H., & Dasgupta, P. K. (1996) · Analytical Chemistry · doi:10.1021/ac960145h · Cited by 751
He, Y., & Lee, H. K. (1997) · Analytical Chemistry · doi:10.1021/ac970242q · Cited by 681
Electrokinetic migration across artificial liquid membranes
Pedersen-Bjergaard, S., & Rasmussen, K. E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.01.025 · Cited by 678
Self-citationDevelopments in liquid-phase microextraction
Psillakis, E., & Kalogerakis, N. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)01007-0 · Cited by 608
Developments in hollow fibre-based, liquid-phase microextraction
Rasmussen, K. E., & Pedersen-Bjergaard, S. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00105-0 · Cited by 520
Self-citationHollow Fiber-Protected Liquid-Phase Microextraction of Triazine Herbicides
Shen, G., & Lee, H. K. (2002) · Analytical Chemistry · doi:10.1021/ac010561o · Cited by 470
Rasmussen, K. E., Pedersen-Bjergaard, S., Krogh, M., Grefslie Ugland, H., & Grønhaug, T. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)01163-2 · Cited by 300
Self-citationMembrane-based techniques for sample enrichment
Jönsson, J. Å., & Mathiasson, L. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00922-5 · Cited by 288
Peng, J.-F., Liu, J.-F., Hu, X.-L., & Jiang, G.-B. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.11.006 · Cited by 276
Audunsson, G. (1986) · Analytical Chemistry · doi:10.1021/ac00126a030 · Cited by 270
Liquid membrane extraction in analytical sample preparation
Jönsson, J. Å., & Mathiasson, L. (1999) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(99)00102-8 · Cited by 265
Zhao, L., & Lee, H. K. (2002) · Analytical Chemistry · doi:10.1021/ac011124c · Cited by 249
Hollow-fibre liquid-phase microextraction of phthalate esters from water
Psillakis, E., & Kalogerakis, N. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00390-x · Cited by 247
Bioanalysis of drugs by liquid-phase microextraction coupled to separation techniques
PEDERSENBJERGAARD, S., & RASMUSSEN, K. (2005) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.08.034 · Cited by 213
Self-citationMemrane extraction in analytical chemistry
Jönsson, J. Å., & Mathiasson, L. (2001) · Journal of Separation Science · doi:10.1002/1615-9314(20010801)24:7<495::aid-jssc495>3.0.co;2-b · Cited by 213
Basheer, C., & Lee, H. K. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.09.083 · Cited by 183
Zhao, L., Zhu, L., & Lee, H. K. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00544-7 · Cited by 170
Recovery, enrichment and selectivity in liquid-phase microextraction
Ho, T. S., Pedersen-Bjergaard, S., & Rasmussen, K. E. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00215-7 · Cited by 164
Self-citationLiquid-phase microextraction and capillary electrophoresis of acidic drugs
Pedersen‐Bjergaard, S., & Rasmussen, K. E. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000201)21:3<579::aid-elps579>3.0.co;2-e · Cited by 156
Self-citationBasheer, C., Lee, H. K., & Obbard, J. P. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00793-8 · Cited by 149
Liquid-phase microextraction and capillary electrophoresis of citalopram, an antidepressant drug
Halvorsen, T. G., Pedersen‐Bjergaard, S., & Rasmussen, K. E. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00868-2 · Cited by 149
Self-citationLambropoulou, D. A., & Albanis, T. A. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.11.076 · Cited by 147
Zhang, J., & Lee, H. K. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.102 · Cited by 147
Basheer, C., Balasubramanian, R., & Lee, H. K. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)01295-0 · Cited by 143
Zhu, L. Y., Zhu, L., & Lee, H. K. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)00906-2 · Cited by 135
Ugland, H. G., Krogh, M., & Rasmussen, K. E. (2000) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)00382-0 · Cited by 131
Self-citationZhu, L. Y., Ee, K. H., Zhao, L., & Lee, H. K. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00138-3 · Cited by 127
Chen, P., & HUANG, S. (2005) · Talanta · doi:10.1016/j.talanta.2005.10.042 · Cited by 121
Liquid-phase microextraction of hydrophilic drugs by carrier-mediated transport
Ho, T. S., Halvorsen, T. G., Pedersen‐Bjergaard, S., & Rasmussen, K. E. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00634-4 · Cited by 120
Self-citationQuintana, J. B., Rodil, R., & Reemtsma, T. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.10.090 · Cited by 112
Dynamic hollow fiber-supported headspace liquid-phase microextraction
Jiang, X., Basheer, C., Zhang, J., & Lee, H. K. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.06.010 · Cited by 110
Hou, L., & Lee, H. K. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.03.012 · Cited by 107
Wu, J., Ee, K. H., & Lee, H. K. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.05.077 · Cited by 107
Hou, L., Shen, G., & Lee, H. K. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01827-7 · Cited by 105
Yamini, Y., Reimann, C. T., Vatanara, A., & Jönsson, J. Å. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.001 · Cited by 104
Kuuranne, T., Kotiaho, T., Pedersen‐Bjergaard, S., Rasmussen, K. E., Leinonen, A., Westwood, S. W., & Kostiainen, R. K. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.393 · Cited by 103
Self-citationReduction of extraction times in liquid-phase microextraction
Halvorsen, T. G., Pedersen‐Bjergaard, S., & Rasmussen, K. E. (2001) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(01)00272-9 · Cited by 103
Self-citationAutomation and optimization of liquid-phase microextraction by gas chromatography
Ouyang, G., Zhao, W., & Pawliszyn, J. B. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.10.093 · Cited by 102
González‐Peñas, E., Leache, C., Viscarret, M., de Obanos, A. P., Araguás, C., & de Ceráin, A. L. (2003) · Journal of Chromatography A · doi:10.1016/j.chroma.2003.10.113 · Cited by 102
Charalabaki, M., Psillakis, E., Mantzavinos, D., & Kalogerakis, N. (2005) · Chemosphere · doi:10.1016/j.chemosphere.2005.01.040 · Cited by 101
Hou, L., & Lee, H. K. (2003) · Analytical Chemistry · doi:10.1021/ac020753z · Cited by 99
Basheer, C., Lee, H. K., & Obbard, J. P. (2003) · Journal of Chromatography A · doi:10.1016/j.chroma.2003.09.043 · Cited by 98
Yazdi, A. S., & Es’haghi, Z. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.05.102 · Cited by 97
Andersen, S. N., Halvorsen, T. G., Pedersen‐Bjergaard, S., & Rasmussen, K. E. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00223-6 · Cited by 96
Self-citationYazdi, A. S., & Es’haghi, Z. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.07.110 · Cited by 96
Xia, L., Hu, B., Jiang, Z., Wu, Y., Chen, R., & Li, L. (2006) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b514623b · Cited by 95
Kinetic Calibration for Automated Hollow Fiber-Protected Liquid-Phase Microextraction
Ouyang, G., & Pawliszyn, J. B. (2006) · Analytical Chemistry · doi:10.1021/ac060669+ · Cited by 92
Basheer, C., Obbard, J. P., & Lee, H. K. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.01.099 · Cited by 92
Ho, T. S., Reubsaet, L., Anthonsen, H. S., Pedersen‐Bjergaard, S., & Rasmussen, K. E. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.11.078 · Cited by 90
Self-citationAndersen, S. N., Halvorsen, T. G., Pedersen‐Bjergaard, S., Rasmussen, K. E., Tanum, L., & Refsum, H. (2003) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(03)00264-4 · Cited by 90
Self-citationKou, D., Wang, X., & Mitra, S. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.09.022 · Cited by 89
King, S., Meyer, J. S., & Andrews, A. R. J. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01594-7 · Cited by 88
Solvent microextraction of chlorinated pesticides
de Jager, L. S., & Andrews, A. R. J. (1999) · Chromatographia · doi:10.1007/bf02497313 · Cited by 88
Two-Step Liquid−Liquid−Liquid Microextraction of Nonsteroidal Antiinflammatory Drugs in Wastewater
Wen, X., Tu, C., & Lee, H. K. (2003) · Analytical Chemistry · doi:10.1021/ac0302354 · Cited by 86
Müller, S., Möder, M., Schrader, S., & Popp, P. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01803-4 · Cited by 83
Liquid-phase microextraction of protein-bound drugs under non-equilibrium conditions
Ho, T. S., Pedersen‐Bjergaard, S., & Rasmussen, K. E. (2002) · The Analyst · doi:10.1039/b110105f · Cited by 82
Self-citationFontanals, N., Barri, T., Bergström, S., & Jonsson, J. A. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.08.026 · Cited by 81
Thordarson, E., Pálmarsdóttir, S., Mathiasson, L., & Jönsson, J. Å. (1996) · Analytical Chemistry · doi:10.1021/ac950929f · Cited by 77
Wu, J., & Lee, H. K. (2006) · Analytical Chemistry · doi:10.1021/ac060966e · Cited by 75
Liquid-phase microextraction of drugs from human breast milk
Bjørhovde, A., Halvorsen, T. G., Rasmussen, K. E., & Pedersen‐Bjergaard, S. (2003) · Analytica Chimica Acta · doi:10.1016/s0003-2670(03)00768-2 · Cited by 75
Self-citationPsillakis, E., Mantzavinos, D., & Kalogerakis, N. E. (2003) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.015 · Cited by 72
Pan, H.-J., & Ho, W. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.08.016 · Cited by 72
Hollow fiber-mediated liquid-phase microextraction of chemical warfare agents from water
Dubey, D. K., Pardasani, D., Gupta, A. K., Palit, M., Kanaujia, P. K., & Tak, V. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.12.095 · Cited by 71
25,000-fold pre-concentration in a single step with liquid-phase microextraction
Ho, T. S., Vasskog, T., Anderssen, T., Jensen, E., Rasmussen, K. E., & Pedersen-Bjergaard, S. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.04.014 · Cited by 70
Self-citationKramer, K., & Andrews, A. R. J. (2001) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(01)00232-8 · Cited by 70
Fundamental studies on selectivity in 3-phase liquid-phase microextraction (LPME) of basic drugs
Pedersen‐Bjergaard, S., Ho, T. S., & Rasmussen, K. E. (2002) · Journal of Separation Science · doi:10.1002/1615-9314(20020201)25:3<141::aid-jssc141>3.0.co;2-3 · Cited by 70
Self-citationHalvorsen, T. G., Pedersen‐Bjergaard, S., Reubsaet, L., & Rasmussen, K. E. (2001) · Journal of Separation Science · doi:10.1002/1615-9314(20010801)24:7<615::aid-jssc615>3.0.co;2-z · Cited by 70
Self-citationVora-adisak, N., & Varanusupakul, P. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.04.009 · Cited by 66
Huang, S.-P., & Huang, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.09.027 · Cited by 66
Zhu, Tu, & Lee, H. K. (2001) · Analytical Chemistry · doi:10.1021/ac0106602 · Cited by 64
de Jager, L. S., & Andrews, A. R. J. (2001) · The Analyst · doi:10.1039/b102039k · Cited by 63
Zhang, J., Su, T., & Lee, H. K. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.04.045 · Cited by 62
Dynamic Liquid−Liquid−Liquid Microextraction with Automated Movement of the Acceptor Phase
Jiang, X., Oh, S. Y., & Lee, H. K. (2005) · Analytical Chemistry · doi:10.1021/ac040153v · Cited by 61
Chia, K., & Huang, S. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.11.072 · Cited by 58
Marlow, M., & Hurtubise, R. J. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.09.054 · Cited by 57
Chen, C.-C., Melwanki, M. B., & Huang, S. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.11.122 · Cited by 57
Leinonen, A., Vuorensola, K., Lepola, L.-M., Kuuranne, T., Kotiaho, T., Ketola, R. A., & Kostiainen, R. K. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.004 · Cited by 56
Berhanu, T., Liu, J., Romero‐González, R., Megersa, N., & Jönsson, J. Å. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.10.082 · Cited by 54
Romero‐González, R., Pastor‐Montoro, E., Martínez-Vidal, J. L., & Frenich, A. G. (2006) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2653 · Cited by 53
Lee, H. S. N., Basheer, C., & Lee, H. K. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.030 · Cited by 52
Bårdstu, K. F., Ho, T. S., Rasmussen, K. E., Pedersen‐Bjergaard, S., & Jönsson, J. Å. (2007) · Journal of Separation Science · doi:10.1002/jssc.200600486 · Cited by 52
Self-citationWu, J., & Lee, H. K. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.07.032 · Cited by 50
Pedersen‐Bjergaard, S., Rasmussen, K. E., Brekke, A., Ho, T. S., & Halvorsen, T. G. (2005) · Journal of Separation Science · doi:10.1002/jssc.200401935 · Cited by 50
Self-citationde Santana, F. J. M., de Oliveira, A. R. M., & Bonato, P. S. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.06.030 · Cited by 49
Three-phase liquid-phase microextraction of weakly basic drugs from whole blood
Ugland, H. G., Krogh, M., & Reubsaet, L. (2003) · Journal of Chromatography B · doi:10.1016/j.jchromb.2003.09.021 · Cited by 49
Yan, C., & Wu, H. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1722 · Cited by 48
Halvorsen, T. G., Pedersen‐Bjergaard, S., Reubsaet, L., & Rasmussen, K. E. (2003) · Journal of Separation Science · doi:10.1002/jssc.200301565 · Cited by 46
Self-citationWu, J., & Lee, H. K. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.08.006 · Cited by 45
Hou, L., Wen, X., Tu, C., & Lee, H. K. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01266-9 · Cited by 44
de Jager, L. S., & Andrews, A. R. J. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(02)00063-6 · Cited by 43
Lambropoulou, D. A., & Albanis, T. A. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.10.064 · Cited by 35
Pedersen‐Bjergaard, S., & Rasmussen, K. E. (2004) · Journal of Separation Science · doi:10.1002/jssc.200401870 · Cited by 32
Self-citationLai, B., Liu, B., Malik, P. K., & Wu, H. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.039 · Cited by 32
Reubsaet, L., Loftheim, H., & Gjelstad, A. (2005) · Journal of Separation Science · doi:10.1002/jssc.200500092 · Cited by 31
Experiences with Carrier-Mediated Transport in Liquid-Phase Microextraction
Ho, T. S., Pedersen‐Bjergaard, S., & Rasmussen, K. E. (2006) · Journal of Chromatographic Science · doi:10.1093/chromsci/44.6.308 · Cited by 28
Self-citationRicholl, S. M., & Colón, I. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.06.004 · Cited by 25
Berry, D. J. (1975) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)82753-3 · Cited by 24
Reubsaet, L., & Paulsen, J. V. (2005) · Journal of Separation Science · doi:10.1002/jssc.200401779 · Cited by 22
Enhancing micro-scale membrane extraction by implementing a barrier film
Wang, X., & Mitra, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.04.052 · Cited by 14
Guo, Y. G., Zhang, J., Liu, D. N., & Fu, H. F. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0868-5 · Cited by 14
Melwanki, M. B., & Huang, S. (2006) · Journal of Separation Science · doi:10.1002/jssc.200600050 · Cited by 13
Research works printed but not linked: 2
- Jönsson, 1992, Trends Anal. Chem., 11, 106, 10.1016/0165-9936(92)85008-S · doi:10.1016/0165-9936(92)85008-s
- Jönsson, 1999, Trends Anal. Chem., 18, 325, 10.1016/S0165-9936(99)00103-X · doi:10.1016/s0165-9936(99)00103-x
Cited by
Nováková, L., & Vlčková, H. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.10.004 · Cited by 595
Lee, J., Lee, H. K., Rasmussen, K. E., & Pedersen-Bjergaard, S. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.050 · Cited by 398
Self-citationBreadmore, M. C., Shallan, A. I., Rabanes, H. R., Gstoettenmayr, D., Abdul Keyon, A. S., Gaspar, A., Dawod, M., & Quirino, J. P. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200396 · Cited by 372
Dadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305
Critical review on recent developments in solventless techniques for extraction of analytes
Nerín, C., Salafranca, J., Aznar, M., & Batlle, R. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2437-6 · Cited by 284
Metadata
- Authors
- Pedersen-Bjergaard, S., & Rasmussen, K. E.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2008-03
- Volume
- 1184
- Issue
- 1-2
- Pages
- 132-142
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W1982152464
- Cited by
- 486
- References
- 104
- FWCI
- 28.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.