The DOI matches its Crossref record.
Liquid-Phase Microextraction in a Single Drop of Organic Solvent by Using a Conventional Microsyringe
Abstract
Two modes of liquid-phase microextraction (LPME) were developed for capillary gas chromatography. Both methodologies, i.e., static LPME and dynamic LPME, involve the use of very small amounts of organic solvent (<2 μL) in a conventional microsyringe. The performance of the two techniques is demonstrated in the determination of two chlorobenzenes extracted into a single drop of toluene by the use of a 10-μL syringe. Static LPME provided some enrichment (∼12-fold), good reproducibility (9.7%), and simplicity but suffered relatively long extraction time (15 min). Dynamic LPME provided higher (∼27-fold) enrichment within much shorter extraction time (∼3 min), and relatively poorer precision (12.8%), primarily due to repeated manual manipulation. Both methods allow the direct transfer of extracted analytes into a gas chromatograph.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 19
- Karlberg B., 1978, Anal. Chim. Acta, 98, 7, 10.1016/S0003-2670(01)83231-1 · DOI
- Kraak J. C., 1983, Trends Anal. Chem., 2, 187, 10.1016/0165-9936(83)80013-2 · DOI
- Onuska F. I., 1989, J. High Resolut. Chromatogr., 12, 11
- Hagen D. R., 1990, Anal. Chim. Acta, 236, 164, 10.1016/S0003-2670(00)83309-7 · DOI
- Arthur C. L., 1992, LC-GC, 10, 661
- Arthur C. L., 1990, Anal. Chem., 62, 2148, 10.1021/ac00218a019 · DOI
- Potter D. W., 1994, Environ. Sci. Technol., 28, 305, 10.1021/es00051a017 · DOI · Paper page
- Murray D. A. J., 1979, J. Chromatogr., 177, 140
- Cantwell F. F., 1996, Anal. Chem., 68, 2240
- Rideal, E. K.An introduction to surface chemistry; Cambridge University Press: Cambridge, U.K., 1930; Chapter 1, p 13.
- Fowlis, I. A.Gas Chromatography, 2nd ed.; Greenwich University Press, John Wiley & Sons: New York, 1995; Chapter 5, p 109.
- Laddha G., 1976, Transport Phenomena in Liquid Extraction
- Cussler, E. L.Diffusion: Mass Transfer in Fluid Systems; Cambridge University Press: Cambridge, U.K., 1984; Chapters 1, 2, 9, and 11.
- Liu S., 1995, Anal. Chem., 67, 2049
- Liu H., 1995, Anal. Chem., 67, 4228
- Jeannot M. A., 1997, Anal. Chem., 69, 239
- Liu H., 1994, Anal. Chim. Acta, 288, 245
- Liu H., 1995, Process Control Qual., 7, 202
- Chen J., 1995, Anal. Chem., 67, 2538
Cited by
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Berijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Sarafraz-Yazdi, A., & Amiri, A. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.10.003 · Cited by 779
Developments in liquid-phase microextraction
Psillakis, E., & Kalogerakis, N. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)01007-0 · Cited by 608
Regueiro, J., Llompart, M., Garcia-Jares, C., Garcia-Monteagudo, J. C., & Cela, R. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.091 · Cited by 547
Metadata
- Authors
- He, Y., & Lee, H. K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-11-01
- Volume
- 69
- Issue
- 22
- Pages
- 4634-4640
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2086924034
- Cited by
- 681
- References
- 0
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liquid-Phase Microextraction in a Single Drop of Organic Solvent by Using a Conventional Microsyringe. https://app.cochat.ai/papers/10.1021/ac970242q
- The paper
- He, Y., & Lee, H. K. (1997). Liquid-Phase Microextraction in a Single Drop of Organic Solvent by Using a Conventional Microsyringe. Analytical Chemistry. https://doi.org/10.1021/ac970242q
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.