The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Particle packed columns and monolithic columns in high-performance liquid chromatography-comparison and critical appraisal
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ordered mesoporous molecular sieves synthesized by a liquid-crystal template mechanism
Kresge, C. T., Leonowicz, M. E., Roth, W. J., Vartuli, J. C., & Beck, J. S. (1992) · Nature · doi:10.1038/359710a0 · Cited by 16,275
Controlled growth of monodisperse silica spheres in the micron size range
Stöber, W., Fink, A., & Bohn, E. (1968) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(68)90272-5 · Cited by 14,532
Iler, K. (1979) · Medical Entomology and Zoology · Cited by 5,030
Hench, L. L., & West, J. K. (1990) · Chemical Reviews · doi:10.1021/cr00099a003 · Cited by 4,450
Perry, J. H. (1950) · Journal of Chemical Education · doi:10.1021/ed027p533.1 · Cited by 3,807
(1990) · Elsevier eBooks · doi:10.1016/c2009-0-22386-5 · Cited by 3,192
(1950) · Journal of the Franklin Institute · doi:10.1016/0016-0032(50)90303-6 · Cited by 2,711
Introduction to Modern Liquid Chromatography
Snyder, L. R., Kirkland, J. J., & Dolan, J. W. (2009) · Wiley eBooks · doi:10.1002/9780470508183 · Cited by 2,460
Adsorption by Powders and Porous Solids
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-598920-6.x5000-3 · Cited by 1,819
Practical HPLC Method Development
Snyder, L. R., Kirkland, J. J., & Glajch, J. L. (1997) · Wiley eBooks · doi:10.1002/9781118592014 · Cited by 1,746
Longitudinal diffusion and resistance to mass transfer as causes of nonideality in chromatography
van Deemter, J. J., Zuiderweg, F. J., & Klinkenberg, A. (1956) · Chemical Engineering Science · doi:10.1016/0009-2509(56)80003-1 · Cited by 1,698
A new form of chromatogram employing two liquid phases
Martin, A. J. P., & Synge, R. L. M. (1941) · Biochemical Journal · doi:10.1042/bj0351358 · Cited by 1,631
Fundamental Research Statistics for the Behavioral Sciences.
Mandeville, G. K., & Roscoe, J. T. (1971) · Journal of the American Statistical Association · doi:10.2307/2284880 · Cited by 1,618
Allen, T. (1981) · Springer eBooks · doi:10.1007/978-1-4899-3063-7 · Cited by 1,472
Practical HPLC Method Development
(1993) · Analytical Chemistry · doi:10.1021/ac00066a728 · Cited by 1,411
Continuous rods of macroporous polymer as high-performance liquid chromatography separation media
Svec, F., & Frechet, J. M. J. (1992) · Analytical Chemistry · doi:10.1021/ac00031a022 · Cited by 951
Octadecylsilylated Porous Silica Rods as Separation Media for Reversed-Phase Liquid Chromatography
Minakuchi, H., Nakanishi, K., Soga, N., Ishizuka, N., & Tanaka, N. (1996) · Analytical Chemistry · doi:10.1021/ac960281m · Cited by 904
Introduction to modern liquid chromatography
(2010) · Choice Reviews Online · doi:10.5860/choice.47-6261 · Cited by 877
Characterization of Porous Solids
Smith, D. M., Hua, D.-W., & Earl, W. L. (1994) · MRS Bulletin · doi:10.1557/s0883769400039518 · Cited by 751
Principles and Application of Self-Diffusion Measurements by Nuclear Magnetic Resonance
KÄRGER, J., PFEIFER, H., & HEINK, W. (1988) · Advances in Magnetic and Optical Resonance · doi:10.1016/b978-0-12-025512-2.50004-x · Cited by 660
Horvath, C. G., Preiss, B. A., & Lipsky, S. R. (1967) · Analytical Chemistry · doi:10.1021/ac60256a003 · Cited by 649
Monolithic silica columns for high-efficiency chromatographic separations
Tanaka, N., Kobayashi, H., Ishizuka, N., Minakuchi, H., Nakanishi, K., Hosoya, K., & Ikegami, T. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)01582-5 · Cited by 497
Sedimentation of Noncolloidal Particles at Low Reynolds Numbers
Davis, R. H., & Acrivos, A. (1985) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.17.010185.000515 · Cited by 462
Applications of silica‐based monolithic HPLC columns
Cabrera, K. (2004) · Journal of Separation Science · doi:10.1002/jssc.200401827 · Cited by 423
High-Performance Liquid Chromatography
(2002) · Analytical Chemistry for Technicians · doi:10.1201/9781420056709-21 · Cited by 420
Nakanishi, K., & Soga, N. (1991) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1991.tb06794.x · Cited by 412
MacNair, J. E., Patel, K. D., & Jorgenson, J. W. (1999) · Analytical Chemistry · doi:10.1021/ac9807013 · Cited by 377
Silica gel-based monoliths prepared by the sol–gel method: facts and figures
SIOUFFI, A. M. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00510-7 · Cited by 370
Practical Aspects of LC Theory
Knox, J. H. (1977) · Journal of Chromatographic Science · doi:10.1093/chromsci/15.9.352 · Cited by 357
The hydrophobic-subtraction model of reversed-phase column selectivity
SNYDER, L., DOLAN, J., & CARR, P. (2004) · Journal of Chromatography A · doi:10.1016/s0021-9673(04)01480-3 · Cited by 338
Advancing LC Performance with Smaller Particles and Higher Pressure
Mazzeo, J. R., D.Neue, U., Kele, M., & Plumb, R. S. (2005) · Analytical Chemistry · doi:10.1021/ac053516f · Cited by 312
The hydrophobic-subtraction model of reversed-phase column selectivity
Snyder, L. R., Dolan, J. W., & Carr, P. W. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.08.121 · Cited by 298
Premstaller, A., Oberacher, H., & Huber, C. G. (2000) · Analytical Chemistry · doi:10.1021/ac000283d · Cited by 283
Euerby, M. R., & Petersson, P. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00393-5 · Cited by 280
Tolstikov, V. V., Lommen, A., Nakanishi, K., Tanaka, N., & Fiehn, O. (2003) · Analytical Chemistry · doi:10.1021/ac034716z · Cited by 260
The Structure and Properties of Materials
Wulff, J., Moffatt, W. G., Pearsall, G. W., Brophy, J. H., Rose, R. M., Hayden, H. W., Shepard, L. A., & Klerer, J. (1967) · Journal of The Electrochemical Society · doi:10.1149/1.2426767 · Cited by 247
Air classification of solid particles: a review
Shapiro, M., & Galperin, V. (2005) · Chemical Engineering and Processing: Process Intensification · doi:10.1016/j.cep.2004.02.022 · Cited by 243
Porous silica : its properties and use as support in column liquid chromatography
Unger, K. K. (1979) · Cited by 212
Self-citationPorous silica—Its properties and use as support in column liquid chromatography
Grushka, E. (1979) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)83851-0 · Cited by 202
Meyers, J. J., & Liapis, A. I. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00443-4 · Cited by 191
Column selectivity in reversed-phase liquid chromatography
Gilroy, J. J., Dolan, J. W., & Snyder, L. R. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00512-0 · Cited by 165
Asperger, A., Efer, J., Koal, T., & Engewald, W. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)01392-9 · Cited by 149
Eeltink, S., Herrero‐Martínez, J. M., Rozing, G. P., Schoenmakers, P. J., & Kok, W. T. (2005) · Analytical Chemistry · doi:10.1021/ac051093b · Cited by 142
Knox, J. H., & Scott, H. P. (1984) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)96162-4 · Cited by 131
Structure Design of Double-Pore Silica and Its Application to HPLC
Nakanishi, K., Minakuchi, H., Soga, N., & Tanaka, N. (1998) · Journal of Sol-Gel Science and Technology · doi:10.1023/a:1008644514849 · Cited by 128
Yao, Y., & Lenhoff, A. M. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.02.054 · Cited by 120
Analysis of wine phenolics by high-performance liquid chromatography using a monolithic type column
Castellari, M., Sartini, E., Fabiani, A., Arfelli, G., & Amati, A. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01195-0 · Cited by 116
Separation and Analysis of Peptides and Proteins
Larive, C. K., Lunte, S. M., Zhong, M., Perkins, M. D., Wilson, G. S., Gokulrangan, G., Williams, T. B., Afroz, F., Schöneich, C., Derrick, T., et al. (1999) · Analytical Chemistry · doi:10.1021/a1990013o · Cited by 110
Gorbunov, A. A., Solovyova, L. Y., & Pasechnik, V. A. (1988) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)84594-5 · Cited by 97
Tallarek, U., Vergeldt, F. J., & As, H. V. (1999) · The Journal of Physical Chemistry B · doi:10.1021/jp990828b · Cited by 94
Use of monolithic supports in proteomics technology
Josić, D., & Clifton, J. G. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.11.082 · Cited by 94
Pham‐Tuan, H., Kaskavelis, L., Daykin, C. A., & Janssen, H. (2003) · Journal of Chromatography B · doi:10.1016/s1570-0232(03)00077-1 · Cited by 84
Amino acid neurotransmitters: separation approaches and diagnostic value
Shah, A. J., Crespi, F., & Heidbreder, C. A. (2002) · Journal of Chromatography B · doi:10.1016/s1570-0232(02)00621-9 · Cited by 84
Walcher, W., Oberacher, H., Troiani, S., et al. (2002) · Journal of Chromatography B · doi:10.1016/s1570-0232(02)00667-0 · Cited by 79
Study of Transport Phenomena in Chromatographic Columns by Pulsed Field Gradient NMR
Tallarek, U., van Dusschoten, D., As, H. V., Bayer, E., & Guiochon, G. A. (1998) · The Journal of Physical Chemistry B · doi:10.1021/jp980250q · Cited by 79
Stofftransport und Stoffverteilung bei chromatographischen Prozessen
Huber, J. F. K. (1973) · Berichte der Bunsengesellschaft für physikalische Chemie · doi:10.1002/bbpc.19730770308 · Cited by 75
Ultrahigh-Throughput Proteomics Using Fast RPLC Separations with ESI-MS/MS
Shen, Y., Smith, R. D., Unger, K. K., Kumar, D., & Lubda, D. (2005) · Analytical Chemistry · doi:10.1021/ac050876u · Cited by 72
Self-citationMonolithic columns for liquid chromatography
Tanaka, N., & Kobayashi, H. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1889-y · Cited by 58
Barbarin, N., Mawhinney, D. B., Black, R. S., & Henion, J. D. (2002) · Journal of Chromatography B · doi:10.1016/s1570-0232(02)00487-7 · Cited by 52
Applications of Monolithic Silica Capillary Columns in Proteomics
Barroso, B., Lubda, D., & Bischoff, R. (2003) · Journal of Proteome Research · doi:10.1021/pr0340532 · Cited by 46
Grimes, B. A., Skudas, R., Unger, K. K., & Lubda, D. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.11.007 · Cited by 43
Self-citationEnantiomer Separation by Capillary Electrochromatography Using Fritless Packed Columns
Fujimoto, C. (2002) · Analytical Sciences · doi:10.2116/analsci.18.19 · Cited by 38
Gzil, P., Baron, G. V., & Desmet, G. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00082-7 · Cited by 34
Machtejevas, E., Andrecht, S., Lubda, D., & Unger, K. K. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.11.042 · Cited by 34
Self-citationLeinweber, F. C., Pfafferodt, M., Seidel‐Morgenstern, A., & Tallarek, U. (2005) · Analytical Chemistry · doi:10.1021/ac050609o · Cited by 30
Key to Analyte Migration and Retention in Electrochromatography
Nischang, I., Spannmann, K., & Tallarek, U. (2006) · Analytical Chemistry · doi:10.1021/ac052133e · Cited by 17
Cited by
Fixed-bed column adsorption study: a comprehensive review
Patel, H. (2019) · Applied Water Science · doi:10.1007/s13201-019-0927-7 · Cited by 821
Recent advances in heavy metal removal by chitosan based adsorbents
Upadhyay, U., Sreedhar, I., Singh, S. A., Patel, C. M., & Anitha, K. L. (2021) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2020.117000 · Cited by 532
Hayes, R., Ahmed, A., Edge, T., & Zhang, H. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.05.010 · Cited by 467
Ikai, T., & Okamoto, Y. (2009) · Chemical Reviews · doi:10.1021/cr8005558 · Cited by 429
Greening analytical chromatography
Welch, C. J., Wu, N., Biba, M., Hartman, R., Brkovic, T., Gong, X., Helmy, R., Schafer, W., Cuff, J., & Pirzada, Z. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.03.008 · Cited by 369
Metadata
- Authors
- Unger, K. K., Skudas, R., & Schulte, M. M.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2008-03
- Volume
- 1184
- Issue
- 1-2
- Pages
- 393-415
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2009497115
- Cited by
- 358
- References
- 66
- FWCI
- 9.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.