CoChat

Simple approach based on ultrasound-assisted emulsification-microextraction for determination of polibrominated flame retardants in water samples by gas chromatography–mass spectrometry

Open access
Fontana, Ariel R., Wuilloud, Rodolfo G., Martínez, Luis D., Altamirano, Jorgelina C. · 2009 · Journal of Chromatography A
Cited by 110

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

A simple, efficient, innovative and environmentally friendly analytical technique was successfully applied for the first time for the extraction and preconcentration of polybrominated diphenyl ethers (PBDEs) from water samples. The PBDEs selected for this work were those most commonly found in the literature in natural water samples: 2,2',4,4'-tetraBDE (BDE-47), 2,2',4,4,5-pentaBDE (BDE-99), 2,2',4,4,6-pentaBDE (BDE-100) and 2,2,4,4',5,5'-hexaBDE (BDE-153). The extracted PBDEs were separated and determined by gas chromatography-mass spectrometry (GC-MS). The extraction/preconcentration technique is based on ultrasound-assisted emulsification-microextraction (USAEME) of a water-immiscible solvent in an aqueous medium. Several variables including, solvent type, extraction time, extraction temperature and matrix modifiers were studied and optimized over the relative response the target analytes. Chloroform was used as extraction solvent in the USAEME technique. Under optimum conditions, the target analytes were quantitatively extracted achieving enrichment factors (EF) higher than 319. The detection limits (LODs) of the analytes for the preconcentration of 10 mL sample volume were within the range 1-2 pg mL(-1). The relative standard deviations (RSD) for five replicates at 10 pg mL(-1) concentration level were <10.3%. The calibration graphs were linear within the concentration range of 5-5000 pg mL(-1) for BDE-47 and BDE-100; and 5-10,000 pg mL(-1) for BDE-99 and BDE-153, respectively. The coefficients of estimation were > or = 0.9985. Validation of the methodology was performed by standard addition method at two concentration levels (10 and 50 pg mL(-1)). Recovery values were > or = 96%, which showed a successful robustness of the analytical methodology for determination of picogram per milliliter of PBDEs in water samples. Significant quantities of PBDEs were not found in the analyzed samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.chroma.2008.11.034

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Fontana, A. R., Wuilloud, R. G., Martínez, L. D., & Altamirano, J. C.
Venue
Journal of Chromatography A
Publisher
Elsevier BV
Published
2009-01
Volume
1216
Issue
1
Pages
147-153
ISSN
0021-9673 (ISSN-L)
OpenAlex
W2089527311
Cited by
110
References
6
FWCI
13.87
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.