CoChat

Dispersive liquid–liquid microextraction applied to the simultaneous derivatization and concentration of triclosan and methyltriclosan in water samples

Open access
Montes, R., Rodríguez, I., Rubí, E., Cela, R. · 2009 · Journal of Chromatography A
Cited by 94

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

A fast and novel sample preparation procedure for the determination of triclosan (TCS) and methyltriclosan (MTCS) in water samples is presented. Dispersive liquid-liquid microextraction, using a ternary mixture consisting of a disperser, an extractant and N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA) as derivatization reagent, was used for the simultaneous derivatization, case of TCS, and concentration of both species in different water samples. Analytes were determined by gas chromatography with tandem mass spectrometry (GC-MS/MS). Influence of different factors on the performance of the sample preparation process is thoroughly discussed. Under final working conditions, a mixture of 1 mL of methanol, 40 microL of 1,1,1-trichloroethane and the same volume of MTBSTFA was added to 10 mL of water in a conical bottom glass tube. After centrifugation, the settled phase was injected directly in the chromatographic system. TCS was quantitatively extracted and converted into the corresponding tert-butyldimethylsilyl derivative, whereas for MTCS an extraction yield around 90% was attained. Limits of quantification between 2 and 5 ng L(-1) and reproducibility values below 10% were achieved; moreover, the performance of the extraction process was scarcely affected by the type of water sample. Globally, these values are comparable, or even better, to those reported for other approaches applied to the determination of same compounds, with the advantage of a shorter sample preparation step. Analysis of surface and wastewater samples confirmed the ubiquitous presence of TCS in the aquatic environment at levels from 20 to 700 ng L(-1).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.chroma.2008.11.068

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 94

Metadata

Authors
Montes, R., Rodríguez, I., Rubí, E., & Cela, R.
Venue
Journal of Chromatography A
Publisher
Elsevier BV
Published
2009-01
Volume
1216
Issue
2
Pages
205-210
ISSN
0021-9673 (ISSN-L)
OpenAlex
W2009221798
Cited by
94
References
7
FWCI
10.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dispersive liquid–liquid microextraction applied to the simultaneous derivatization and concentration of triclosan and methyltriclosan in water samples. https://app.cochat.ai/papers/10.1016/j.chroma.2008.11.068
The paper
Montes, R., Rodríguez, I., Rubí, E., & Cela, R. (2009). Dispersive liquid–liquid microextraction applied to the simultaneous derivatization and concentration of triclosan and methyltriclosan in water samples. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2008.11.068

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.