Hollow fiber supported ionic liquid membrane microextraction for determination of sulfonamides in environmental water samples by high-performance liquid chromatography
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
By using ionic liquid as membrane liquid and tri-n-octylphosphine oxide (TOPO) as additive, hollow fiber supported liquid phase microextraction (HF-LPME) was developed for the determination of five sulfonamides in environmental water samples by high-performance liquid chromatography with ultraviolet detection The extraction solvent and the parameters affecting the extraction enrichment factor such as the type and amount of carrier, pH and volume ratio of donor phase and acceptor phase, extraction time, salt-out effect and matrix effect were optimized. Under the optimal extraction conditions (organic liquid membrane phase: [C(8)MIM][PF(6)] with 14% TOPO (w/v); donor phase: 4mL, pH 4.5 KH(2)PO(4) with 2M Na(2)SO(4); acceptor phase: 25microL, pH 13 NaOH; extraction time: 8 h), low detection limits (0.1-0.4microg/L, RSD<or=5%) and good linear range (1-2000ng/mL, R(2)>or=0.999) were obtained for all the analytes. The presence of humic acid (0-25mg/L dissolved organic carbon) and bovine serum albumin (0-100microg/mL) had no significant effect on the extraction efficiency. Good spike recoveries over the range of 82.2-103.2% were obtained when applying the proposed method on five real environmental water samples. These results indicated that this present method was very sensitive and reliable with good repeatabilities and excellent clean-up in water samples. The proposed method confirmed hollow fiber supported ionic liquid membrane based LPME to be robust to monitoring trace levels of sulfadiazine, sulfamerazine, sulfamethazine, sulfadimethoxine and sulfamethoxazole in aqueous samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peng, J.-F., Liu, J.-F., Hu, X.-L., & Jiang, G.-B. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.11.006 · Cited by 276
Self-citation
Cited by
Ionic liquids in analytical chemistry
Sun, P., & Armstrong, D. W. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.12.007 · Cited by 727
Recent advances in supported ionic liquid membrane technology
Lozano, L. J., Godínez, C., de los Ríos, A. P., Hernández-Fernández, F. J., Sánchez-Segado, S., & Alguacil, F. J. (2011) · Journal of Membrane Science · doi:10.1016/j.memsci.2011.03.036 · Cited by 401
Extraction with environmentally friendly solvents
Płotka-Wasylka, J., Rutkowska, M., Owczarek, K., Tobiszewski, M., & Namieśnik, J. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.03.006 · Cited by 383
“analysis of phthalate esters in tea beverages [40], sulfonamides in environmental water samples [41].”
BackgroundGreen aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Trends in liquid-phase microextraction, and its application to environmental and biological samples
Han, D., & Row, K. H. (2012) · Microchimica Acta · doi:10.1007/s00604-011-0678-0 · Cited by 175
Metadata
- Authors
- Tao, Y., Liu, J.-F., Hu, X.-L., Li, H.-C., Wang, T., & Jiang, G.-B.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2009-08
- Volume
- 1216
- Issue
- 35
- Pages
- 6259-6266
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W1978841449
- Cited by
- 152
- References
- 1
- FWCI
- 16.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.