Cited by 60Per- and polyfluoroalkyl substances researchAnalytical chemistry methods developmentEnvironmental and Analytical Chemistry Studies

Comparison of two extraction methods for the analysis of per- and polyfluorinated chemicals in digested sewage sludge

Zhang, Tao, Sun, Hongwen, Gerecke, Andreas C., Kannan, Kurunthachalam, Müller, Claudia E., Alder, Alfredo C.·2010·Journal of Chromatography A

Abstract

A rapid and reliable analytical method, based on ion-pair extraction, clean-up on Envicarb cartridge and detection by liquid chromatography-tandem mass spectrometry (LC-MS/MS), was developed for determination of 17 per- and polyfluorinated chemicals (PFCs) in digested sewage sludge. Envicarb cartridge and six labeled internal standards were selected for the elimination/reduction and correction of matrix effects, respectively. As a result, the matrix effect for perfluorooctane sulfonamides (FOSAs) and perfluorocarboxylic acids (PFCAs) with carbon chain length from C6 to C14 was lowered to a range of -14% to +28%. However, the matrix effect for other analytes was still great mainly due to the absence of appropriate internal standard. Mean recoveries of the target analytes based on matrix spikes, at different spike levels (10-300ng/g), ranged from 70% to 169%. Relative standard deviations (RSDs) were in the range of 2-20% at different spike levels. The limit of quantification (LOQ) ranged between 0.6 and 30ng/g. The method was successfully applied to several sewage sludge samples from wastewater treatment plants nearby Zürich, Switzerland. In addition, by comparing the accuracy and precision of ion-pair extraction method and methanol extraction method, we further demonstrated that the ion-pair extraction method can be used for the analysis of PFCs in sludge samples. To our knowledge, this is the first study to extract the PFCs in sewage sludge with ion-pair method and to find unsaturated fluorotelomer carboxylic acids (FTUCAs) in sewage sludge.

Integrity signals

Registry

Crossref · 10.1016/j.chroma.2010.05.061

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zhang, T., Sun, H., Gerecke, A. C., Kannan, K., Müller, C. E., & Alder, A. C.
Affiliations
  • Nankai University (CN)
  • Empa (CH)
  • New York State Department of Health (US)
  • Swiss Federal Institute of Aquatic Science and Technology (CH)
Corresponding author
  • Sun, Hongwen
  • Alder, Alfredo C.
Venue
Journal of Chromatography A
Publisher
Elsevier BV
Published
2010-07
Volume
1217
Issue
31
Pages
5026-5034
ISSN
0021-9673 (ISSN-L)
OpenAlex
W2044849112
Cited by
60
References
2
Citations by year
2026: 1 · 2025: 3 · 2024: 3 · 2023: 2 · 2022: 4 · 2021: 3 · 2020: 3 · 2019: 3 · 2018: 1 · 2017: 2 · 2016: 5 · 2015: 5 · 2014: 6 · 2013: 6 · 2012: 8
FWCI
5.12
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Chromatography A (publishedVersion)
  • PubMed (publishedVersion)
  • DORA Eawag (Swiss Federal Institute of Aquatic Science and Technology (Eawag)) (submittedVersion)
  • DORA Empa (Swiss Federal Laboratories for Materials Science and Technology (Empa)) (submittedVersion)
Topics
  • Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Environmental Science › Water Science and Technology › Environmental and Analytical Chemistry Studies
Keywords
sewage sludge, ion-pair extraction, matrix effect correction, perfluorooctane sulfonamide, perfluorocarboxylic acids, fluorotelomer carboxylic acids, wastewater treatment plants, environmental pollutants
MeSH terms
Chromatography, Liquid, Chemical Fractionation, Hydrocarbons, Fluorinated, Sewage, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review