The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Comparative Analysis of Mass Spectral Matching-Based Compound Identification in Gas Chromatography-Mass Spectrometry
Open accessAbstract
Compound identification in gas chromatography-mass spectrometry (GC-MS) is usually achieved by matching query spectra to spectra present in a reference library. Although several spectral similarity measures have been developed and compared using a small reference library, it still remains unknown how the relationship between the spectral similarity measure and the size of reference library affects on the identification accuracy as well as the optimal weight factor. We used three reference libraries to investigate the dependency of the optimal weight factor, spectral similarity measure and the size of reference library. Our study demonstrated that the optimal weight factor depends on not only spectral similarity measure but also the size of reference library. The mixture semi-partial correlation measure outperforms all existing spectral similarity measures in all tested reference libraries, in spite of the computational expense. Furthermore, the accuracy of compound identification using a larger reference library in future is estimated by varying the size of reference library. Simulation study indicates that the mixture semi-partial correlation measure will have the best performance with the increase of reference library in future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
GC-MS metabolite identification compared deconvoluted spectra with pure spectra of standards when available and with the NIST library using a minimum match quality of 90%.
“The spectra obtained after deconvolution were compared with the pure spectra of standards, when available, and the spectra available, with the NIST library (a match quality of 90% minimum was used as a criterion (v 2.2 g distributed with NIST 2014, USA)) [38].”
From Comprehensive Metabolomic Fingerprinting Combined with Chemometrics Identifies Species- and Variety-Specific Variation of Medicinal Herbs: An Ocimum Study (2023) · cites this paper as [38]
The Introduction and Methods §2.1 describe matching experimental mass spectra against reference libraries, including NIST libraries. They do not describe comparing deconvoluted spectra with pure standards or applying a minimum match-quality threshold of 90%; Methods §2.6 instead defines identification by spectral-similarity ranking and matching CAS numbers. Page numbers were not available in our copy. (LLM, conf=0.88)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daubechies, I. C., & Heil, C. (1992) · Computers in Physics · doi:10.1063/1.4823127 · Cited by 16,353
Brigham, E. O., & Yuen, C. K. (1978) · IEEE Transactions on Systems Man and Cybernetics · doi:10.1109/tsmc.1978.4309919 · Cited by 1,039
Optimization and testing of mass spectral library search algorithms for compound identification
Stein, S. E., & Scott, D. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)87009-8 · Cited by 882
Ahmed, N., & Rao, K. R. (1975) · Springer eBooks · doi:10.1007/978-3-642-45450-9_4 · Cited by 369
Identification of mass spectra by computer-searching a file of known spectra
Hertz, H. S., Hites, R. A., & BIEMANN, K. (1971) · Analytical Chemistry · doi:10.1021/ac60301a009 · Cited by 305
Koo, I., Zhang, X., & Kim, S. (2011) · Analytical Chemistry · doi:10.1021/ac200740w · Cited by 86
Self-citationAtwater, B. L., Stauffer, D. B., McLafferty, F. W., & Peterson, D. W. (1985) · Analytical Chemistry · doi:10.1021/ac00281a028 · Cited by 71
The Evaluation of Mass Spectral Search Algorithms
Rasmussen, G. T., & ISENHOUR, T. L. (1979) · Journal of Chemical Information and Computer Sciences · doi:10.1021/ci60019a014 · Cited by 69
Kim, S., Koo, I., Jeong, J., Wu, S., Shi, X., & Zhang, X. (2012) · Analytical Chemistry · doi:10.1021/ac301350n · Cited by 67
Self-citationKim, S., Koo, I., Wei, X., & Zhang, X. (2012) · Bioinformatics · doi:10.1093/bioinformatics/bts083 · Cited by 61
Self-citationiMatch: A retention index tool for analysis of gas chromatography–mass spectrometry data
Zhang, J., Fang, A., Wang, B., et al. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.07.039 · Cited by 50
Julian, R. K., Higgs, R. E., Gygi, J. D., et al. (1998) · Analytical Chemistry · doi:10.1021/ac971055v · Cited by 44
Zhao, Y., Zhang, J., Wang, B., et al. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.02.072 · Cited by 28
Koo, I., Zhao, Y., Zhang, J., et al. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.08.068 · Cited by 8
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Rai, A. K., Khan, S., Kumar, A., Dubey, B. K., Lal, R. K., Tiwari, A., Trivedi, P. K., Elliott, C. T., & Ch, R. (2023) · Metabolites · doi:10.3390/metabo13010122 · Cited by 33
“The UPLC analysis was performed on an instrument of the Agilent 1290 series (Agilent Technologies, Santa Carla, CA, USA), composed of a Binary pump (G7120A), autosampler (G7129A), Column oven (G7130A), and diode array detector (G4212B).”
Influential
Metadata
- Authors
- Koo, I., Kim, S., & Zhang, X.
- Affiliations
- University of Louisville (US)
- Corresponding author
- Zhang, Xiang
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2013-07
- Volume
- 1298
- Pages
- 132-138
- ISSN
- 0021-9673 (ISSN-L)
- PMC
- PMC3686837
- OpenAlex
- W2003158912
- Cited by
- 104
- References
- 14
- Citations by year
- 2026: 10 · 2025: 7 · 2024: 8 · 2023: 10 · 2022: 7 · 2021: 5 · 2020: 15 · 2019: 8 · 2018: 4 · 2017: 5 · 2016: 9 · 2015: 5 · 2014: 8 · 2013: 2
- FWCI
- 7.63
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Chromatography A (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health
- National Institute of General Medical Sciences (R01GM087735)
- National Institute of Environmental Health Sciences (R21ES021311)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Keywords
- compound identification, spectral similarity measures, gas chromatography-mass spectrometry, identification accuracy
- MeSH terms
- Algorithms, Gas Chromatography-Mass Spectrometry, Molecular Weight
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review