Cited by 22Per- and polyfluoroalkyl substances researchMass Spectrometry Techniques and ApplicationsMetabolomics and Mass Spectrometry Studies

Data-independent acquisition with ion mobility mass spectrometry for suspect screening of per- and polyfluoroalkyl substances in environmental water samples

Yukioka, Satoru, Tanaka, Shuhei, Suzuki, Yuji, Echigo, Shinya, Fujii, Shigeo·2021·Journal of Chromatography A

Abstract

Per- and polyfluoroalkyl substances (PFASs) have environmentally persistent, and the various types of PFASs have been detected in water environments. Many previous studies have performed data-dependent acquisition (DDA) of mass spectra from an environmental sample by high-resolution mass spectrometry to identify PFAS suspects individually. In comparison, the data-independent acquisition (DIA) of comprehensive mass spectra of the sample is a technology which enables to know the occurrences of suspects and non-targets simultaneously. However, it is difficult to associate the fragment ions of targeted precursor ions by retention time only, because of the existence of co-eluting ions derived from environmental samples. Since the separation of ions is not enough with only the conventional DIA method, here, we attempted to support it using ion mobility mass spectrometry (IMS) to distinguish the relevant ions from co-eluting ions by drift time. Firstly, suspect screening of PFASs with eternal database resulted in determining 32-96 PFAS suspects in firefighting foam impacted groundwater samples (n = 8) by suspect screening. Among all the pairs of respective precursor ions and fragment ions of the PFAS suspects, 5%-19% (4-9 PFASs) of them were associated without considering the drift time of IMS, while 37%-49% (15-43 PFASs) of them were associated with considering the drift time. The consideration of the drift time increased the association ratios in all samples. In a sample, most pre…

Integrity signals

Registry

Crossref · 10.1016/j.chroma.2021.461899

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • LC-HRMS and GC-HRMS are increasingly used for SSA and NTA, enabling tentative identification of unknown or emerging PFAS based on accurate mass, retention time, and fragmentation patterns.

    “High-resolution techniques such as LC–HRMS and GC–HRMS are increasingly used for SSA and NTA, enabling tentative identification of unknown or emerging PFAS based on accurate mass, retention time, and fragmentation patterns [15].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Yukioka, S., Tanaka, S., Suzuki, Y., Echigo, S., & Fujii, S.
Affiliations
Kyoto University (JP)
Corresponding author
Yukioka, Satoru
Venue
Journal of Chromatography A
Publisher
Elsevier BV
Published
2021-02
Volume
1638
Pages
461899
ISSN
0021-9673 (ISSN-L)
OpenAlex
W3120205916
Cited by
22
References
3
Citations by year
2026: 3 · 2025: 5 · 2024: 1 · 2023: 6 · 2022: 5 · 2021: 2
FWCI
1.32
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Chromatography A (publishedVersion)
  • PubMed (publishedVersion)
Funders
Japan Society for the Promotion of Science (18J13848)
Topics
  • Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
per- and polyfluoroalkyl substances, data-independent acquisition, ion mobility mass spectrometry, drift time, firefighting foam, groundwater contamination, environmental water samples, non-target screening
MeSH terms
Ion Mobility Spectrometry, Fluorocarbons, Image Processing, Computer-Assisted, Water Pollutants, Chemical, Tandem Mass Spectrometry, Groundwater

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review