A New Algorithm for the Diagnosis of Hypertension in Canada
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Accurate blood pressure measurement is critical to properly identify and treat individuals with hypertension. In 2005, the Canadian Hypertension Education Program produced a revised algorithm to be used for the diagnosis of hypertension. Subsequent annual reviews of the literature have identified 2 major deficiencies in the current diagnostic process. First, auscultatory measurements performed in routine clinical settings have serious accuracy limitations that have not been overcome despite great efforts to educate health care professionals over several years. Thus, alternatives to auscultatory measurements should be used. Second, recent data indicate that patients with white coat hypertension must be identified earlier in the process and in a systematic manner rather than on an ad hoc or voluntary basis so they are not unnecessarily treated with antihypertensive medications. The economic and health consequences of white coat hypertension are reviewed. In this article evidence for a revised algorithm to diagnose hypertension is presented. Protocols for home blood pressure measurement and ambulatory blood pressure monitoring are reviewed. The role of automated office blood pressure measurement is updated. The revised algorithm strongly encourages the use of validated electronic digital oscillometric devices and recommends that out-of-office blood pressure measurements, ambulatory blood pressure monitoring (preferred), or home blood pressure measurement, should be performed to confirm the diagnosis of hypertension.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Dolan, E., Stanton, A., Thijs, L., Hinedi, K., Atkins, N., McClory, S., Hond, E. D., McCormack, P., Staessen, J. A., & O’Brien, E. (2005) · Hypertension · doi:10.1161/01.hyp.0000170138.56903.7a · Cited by 1,227 · cited 8×
“Prospective studies have led to a better understanding of the predictive power of HBPM compared with clinic-based measurements.(78,81,87,90,101,102,116) Ward et al.”
InfluentialPrognostic Value of Ambulatory Blood-Pressure Recordings in Patients with Treated Hypertension
Clement, D. L., De Buyzere, M. L., De Bacquer, D. A., de Leeuw, P. W., Duprez, D. A., Fagard, R. H., Gheeraert, P. J., Missault, L. H., Braun, J. J., Six, R. O., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022273 · Cited by 1,085 · cited 1×
“The device should be set to record for a duration of at least 24 hours,(78,106-115) and the measurement frequency set at 20-30 minute intervals during the day, and 30-60 minute intervals during the night.(78,106,107,110,112-114) A patientreported diary to define daytime (awake) and nighttime (sleep) activities, sympto…”
Sega, R., Facchetti, R., Bombelli, M., Cesana, G., Corrao, G., Grassi, G., & Mancia, G. (2005) · Circulation · doi:10.1161/01.cir.0000160923.04524.5b · Cited by 1,009
Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study
Boggia, J., Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Kuznetsova, T., Torp-Pedersen, C., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61538-4 · Cited by 887
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Fagard, R. H., Celis, H., Thijs, L., Staessen, J. A., Clement, D. L., De Buyzere, M. L., & De Bacquer, D. A. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.100727 · Cited by 742
Mancia, G., Facchetti, R., Bombelli, M., Grassi, G., & Sega, R. (2006) · Hypertension · doi:10.1161/01.hyp.0000215363.69793.bb · Cited by 691 · cited 1×
“The device should be set to record for a duration of at least 24 hours,(78,106-115) and the measurement frequency set at 20-30 minute intervals during the day, and 30-60 minute intervals during the night.(78,106,107,110,112-114) A patientreported diary to define daytime (awake) and nighttime (sleep) activities, sympto…”
Predictive Role of the Nighttime Blood Pressure
Hansen, T. W., Li, Y., Boggia, J., Thijs, L., Richart, T., & Staessen, J. A. (2011) · Hypertension · doi:10.1161/hypertensionaha.109.133900 · Cited by 597 · cited 2×
“Several pathophysiological mechanisms have been proposed to be implicated in the occurrence of cardiovascular events with higher nighttime BP, including disturbed baroreflex sensitivity, alterations in the sympathetic modulation of the nighttime BP, sleep apnea, increased salt sensitivity necessitating a higher BP at…”
Cited by
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
Self-citationDaskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Self-citationWhite-coat hypertension is a risk factor for cardiovascular diseases and total mortality
Huang, Y., Huang, W., Mai, W., Cai, X., An, D., Liu, Z., Huang, H., Zeng, J., Hu, Y., & Xu, D. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001226 · Cited by 202
“However, it should be noted that the diagnostic agreement between ABPM and HBPM was moderate [40].”
BackgroundKario, K., Shin, J., Chen, C., Buranakitjaroen, P., Chia, Y., Divinagracia, R., Nailes, J., Hoshide, S., Siddique, S., Sison, J., et al. (2019) · The Journal of Clinical Hypertension · doi:10.1111/jch.13652 · Cited by 164
Padwal, R., Campbell, N. R. C., Schutte, A. E., Olsen, M. H., Delles, C., Etyang, A., Cruickshank, J. K., Stergiou, G., Rakotz, M. K., Wozniak, G., et al. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002112 · Cited by 108
“Both out-of-clinic measurementmodalities requireproper technique, andhealthcare professionals must understand that home BP monitoring requires patient training in order to be effective in improving clinical decisions [33,36,39].”
BackgroundSelf-citationMuntner, P., Carey, R. M., Jamerson, K., Wright, J. T., & Whelton, P. K. (2019) · Hypertension · doi:10.1161/hypertensionaha.118.11946 · Cited by 62
(2017) · PubMed Central · Cited by 52
Villar, R., Sánchez, R. A., Boggia, J., Peñaherrera, E., Lopez, J., Barroso, W. S., Barbosa, E., Cobos, L., Hernández Hernández, R., Octavio, J. A., et al. (2020) · The Journal of Clinical Hypertension · doi:10.1111/jch.13815 · Cited by 28
Metadata
- Authors
- Cloutier, L., Daskalopoulou, S. S., Padwal, R. S., Lamarre-Cliche, M., Bolli, P., McLean, D., Milot, A., Tobe, S. W., Tremblay, G., McKay, D. W., Townsend, R., Campbell, N., & Gelfer, M.
- Venue
- Canadian Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 2015-05
- Volume
- 31
- Issue
- 5
- Pages
- 620-630
- ISSN
- 0828-282X (ISSN-L)
- OpenAlex
- W2148066253
- Cited by
- 99
- References
- 23
- FWCI
- 12.71
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.