The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Adsorption kinetic modeling using pseudo-first order and pseudo-second order rate laws: A review
Open accessAbstract
Adsorption for water and wastewater treatment has been the subject of many research in the scientific community, focusing mainly on either equilibrium or kinetic studies. Adsorption kinetics are commonly modeled using pseudo-first and pseudo-second order rate laws. Analyses of published works in the past two decades indicated that the pseudo-second order is considered to be the superior model as it can represent many adsorption systems. However, critical assessment of modeling techniques and practices suggests that its superiority could be a consequence of currently acceptable modeling norms which tend to favor the pseudo-second order model. The partiality was due to several modeling pitfalls that are often neglected. In addition, commonly used model validation tools are often used haphazardly and redundantly. As such, they cannot sufficiently provide any kind of certainty on the validity of a model. To eliminate modeling biasness, a new validation method was proposed and was then employed to re-examine previously published adsorption kinetic data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pseudo-second order model for sorption processes
Ho, Y. S., & McKay, G. (1999) · Process Biochemistry · doi:10.1016/s0032-9592(98)00112-5 · Cited by 17,497
Gunst, R. F. (1999) · Technometrics · doi:10.1080/00401706.1999.10485680 · Cited by 4,002
Simonin, J.-P. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.04.079 · Cited by 2,100
Design and Analysis of Experiments: Special Designs and Applications
(2012) · Wiley Series in Probability and Statistics · doi:10.1002/9781118147634 · Cited by 2,031
Insight into the adsorption kinetics models for the removal of contaminants from aqueous solutions
Tan, K. L., & Hameed, B. H. (2017) · Journal of the Taiwan Institute of Chemical Engineers · doi:10.1016/j.jtice.2017.01.024 · Cited by 1,206
Largitte, L., & Pasquier, R. (2016) · Chemical Engineering Research and Design · doi:10.1016/j.cherd.2016.02.006 · Cited by 1,148
Srivastava, V. C., Swamy, M. M., Mall, I. D., Prasad, B., & Mishra, I. M. (2006) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2005.07.016 · Cited by 918
Mall, I. D., Srivastava, V. C., Agarwal, N. K., & Mishra, I. M. (2005) · Chemosphere · doi:10.1016/j.chemosphere.2005.03.065 · Cited by 777
Adsorptive removal of methylene blue by tea waste
Uddin, M. T., Islam, M. A., Mahmud, S., & Rukanuzzaman, M. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.07.131 · Cited by 568
Robati, D. (2013) · Journal of Nanostructure in Chemistry · doi:10.1186/2193-8865-3-55 · Cited by 501
Cited by
Cao, Y., Zhao, M., Ma, X., Song, Y., Zuo, S., Li, H., & Deng, W. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2021.147620 · Cited by 606
On validity, physical meaning, mechanism insights and regression of adsorption kinetic models
Vareda, J. P. (2023) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2023.121416 · Cited by 380
Pereira, L., Castillo, V., Calero, M., Blázquez, G., Solís, R. R., & Martín-Lara, M. Á. (2024) · Journal of Water Process Engineering · doi:10.1016/j.jwpe.2024.105386 · Cited by 45
Metadata
- Authors
- Revellame, E. D., Fortela, D. L., Sharp, W., Hernandez, R., & Zappi, M. E.
- Venue
- Cleaner Engineering and Technology
- Publisher
- Elsevier BV
- Published
- 2020-12
- Volume
- 1
- Pages
- 100032
- ISSN
- 2666-7908 (ISSN-L)
- OpenAlex
- W3112726656
- Cited by
- 1,397
- References
- 38
- FWCI
- 25.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adsorption kinetic modeling using pseudo-first order and pseudo-second order rate laws: A review. https://app.cochat.ai/papers/10.1016/j.clet.2020.100032
- The paper
- Revellame, E. D., Fortela, D. L., Sharp, W., Hernandez, R., & Zappi, M. E. (2020). Adsorption kinetic modeling using pseudo-first order and pseudo-second order rate laws: A review. Cleaner Engineering and Technology. https://doi.org/10.1016/j.clet.2020.100032
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.