Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 164

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

A stabilizing reagent prevents cell-free DNA contamination by cellular DNA in plasma during blood sample storage and shipping as determined by digital PCR

Open access
Norton, S.E., Lechner, J.M., Williams, T., Fernando, M.R. · 2013 · Clinical Biochemistry

Abstract

OBJECTIVES: To study the ability of a stabilizing reagent to prevent cellular DNA contamination of cell-free DNA (cfDNA) in plasma during whole blood sample storage and shipping. DESIGN AND METHODS: Samples were drawn from healthy donors into K₃EDTA and Cell-Free DNA BCTs (BCT) and stored at room temperature (RT). Aliquots were removed at specified time points and cfDNA was purified from the plasma. A Droplet Digital PCR (ddPCR) assay that amplifies a short β-actin gene fragment (136 bp) was used to measure the total plasma cfDNA (pDNA) concentration while a longer β-actin fragment (420 bp) was used to quantify genomic DNA (gDNA). In a follow-up experiment, blood samples drawn into the same types of tubes were shipped round trip by overnight air before cfDNA was isolated and analyzed. RESULTS: Blood stored in K₃EDTA tubes at RT showed increases in pDNA and gDNA concentrations over time. However, both pDNA and gDNA levels remained stable in BCT for at least seven days. On day 14, there was a 4.5-fold increase in pDNA in BCT as compared to >200-fold increase in K₃EDTA tubes. Likewise, gDNA increased <2-fold on day 14 in BCT as opposed to a 456-fold increase in K₃EDTA tubes. Similar results were observed after samples were shipped. CONCLUSIONS: Cell-Free DNA BCTs prevent gDNA contamination that may occur due to nucleated cell disruption during sample storage and shipping. This novel blood collection tube provides a method for obtaining stable cfDNA samples for rare target detection and accurate analysis while mitigating the threat of gDNA contamination.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.clinbiochem.2013.06.002

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • High-throughput droplet digital PCR system for absolute quantitation of DNA copy number

    Hindson, B. J., Ness, K. D., Masquelier, D. A., Belgrader, P., Heredia, N. J., Makarewicz, A. J., Bright, I. J., Lucero, M. Y., Hiddessen, A. L., Legler, T. C., et al. (2011) · Analytical Chemistry · doi:10.1021/ac202028g · Cited by 2,792 · cited 1×

    “End-point PCR then individually amplifies and analyzes for the presence or absence of target DNA using fluorescence probes [12].”
    Method
  • Digital PCR

    Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770 · cited 1×

    “However, most manufacturers of real-time quantitative PCR (qPCR) instruments and reagents recommend amplicon lengths of 80–150 bp, since longer products show decreased amplification efficiencies, which can increase variation and decrease the reliability of results [11].”
    Background

Cited by

See all 164

Metadata

Authors
Norton, S. E., Lechner, J. M., Williams, T., & Fernando, M. R.
Venue
Clinical Biochemistry
Publisher
Elsevier BV
Published
2013-10
Volume
46
Issue
15
Pages
1561-1565
ISSN
0009-9120 (ISSN-L)
OpenAlex
W2057379745
Cited by
164
References
2
FWCI
3.21
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.