The DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.
LC–MS/MS analysis of steroids in the clinical laboratory
Abstract
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a powerful tool that is changing the way we analyse steroids in the clinical laboratory. It is already opening up the field of steroid analysis in endocrinology and is providing new applications for individual steroids and panels of steroids in different clinical conditions. LC-MS/MS is now well-accepted technology and is increasingly being used to replace problematic immunoassay methods because of greater sensitivity and specificity. Improved sample preparation, modern chromatography methods, and sensitive, faster scanning mass spectrometers have all played a role in improving LC-MS/MS. LC-MS/MS is also playing a key role in improving the quality of assays through the development of reference measurement procedures, characterisation of reference materials and multi-site calibration programmes. There is increasing interest in multiplexing steroid assays into panels of diagnostic tests to aid and improve the diagnosis and monitoring of disease.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A range of liquid chromatography tandem mass spectrometry assays for salivary cortisol/cortisone and salivary androgens have thus been developed and implemented in routine clinical laboratories (Keevil, 2016).”
From Intracrine androgen biosynthesis, metabolism and action revisited (2018) · cites this paper as Keevil, 2016
Citations
Cites
Salivary cortisol as a biomarker in stress research
Hellhammer, D. H., Wüst, S., & Kudielka, B. M. (2009) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2008.10.026 · Cited by 1,925
The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry
Hoofnagle, A. N., & Wener, M. H. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2009.06.003 · Cited by 562
Urine steroid metabolomics as a biomarker tool for detecting malignancy in adrenal tumors
Arlt, W., Biehl, M., Taylor, A. E., Hahner, S., Libé, R., Hughes, B. A., Schneider, P., Smith, D. J., Stiekema, H., Krone, N., et al. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-1565 · Cited by 458
Krone, N., Hughes, B. A., Lavery, G. G., Stewart, P. M., Arlt, W., & Shackleton, C. H. L. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.04.010 · Cited by 434
Challenges to the measurement of estradiol: an Endocrine Society Position Statement
Rosner, W., Hankinson, S. E., Sluss, P. M., Vesper, H. W., & Wierman, M. E. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-3780 · Cited by 408
Handelsman, D. J., & Wartofsky, L. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-3375 · Cited by 368
Nelson, R. E., Grebe, S. K. G., O’Kane, D. J., & Singh, R. J. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.025478 · Cited by 359
LC-MS/MS in the Clinical Laboratory - Where to From Here?
Grebe, S. K. G., & Singh, R. J. (2011) · Europe PMC (PubMed Central) · Cited by 356
Bhasin, S., Pencina, M., Jasuja, G. K., Travison, T. G., Coviello, A., Orwoll, E., Wang, P. Y., Nielson, C., Wu, F., Tajar, A., et al. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-3012 · Cited by 355
Mass spectrometry and immunoassay: how to measure steroid hormones today and tomorrow
Taylor, A. E., Keevil, B., & Huhtaniemi, I. T. (2015) · European Journal of Endocrinology · doi:10.1530/eje-15-0338 · Cited by 320
Self-citation
Research works printed but not linked: 6
- Cuzzola, 2014, A comprehensive study for the validation of a LC–MS/MS method for the determination of free and total forms of urinary cortisol and its metabolites, J. Pharm. Biomed. Anal., 94, 203, 10.1016/j.jpba.2014.02.003 · DOI
- Eisenhofer, 2014, Phenotype in congenital adrenal hyperplasia, Metabolomics, 10, 123, 10.1007/s11306-013-0558-1 · DOI
- Owen, 2013, Supported liquid extraction as an alternative to solid phase extraction for LC–MS/MS aldosterone analysis?, Ann. Clin. Biochem., 50, 489, 10.1177/0004563213480758 · DOI
- Szarka, 2013, Separation of dansylated 17βestradiol, 17αestradiol and estrone on a single HPLC column for simultaneous quantitation by LC–MS/MS, Anal. Bioanal. Chem., 405, 3399, 10.1007/s00216-013-6710-y · DOI
- Owen, 2015, A direct assay for the routine measurement of testosterone, androstenedione, dihydrotestosterone and dehydroepiandrosterone by LC–MS/MS, Ann. Clin. Biochem.
- Koal, 2012, Standardized LC–MS/MS based steroid hormone profile-analysis, J. Steroid Biochem. Mol. Biol., 129, 129, 10.1016/j.jsbmb.2011.12.001 · DOI
Cited by
Sorted by citations
After another decade: LC–MS/MS became routine in clinical diagnostics
Seger, C., & Salzmann, L. (2020) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2020.03.004 · Cited by 309
11-Oxygenated C19 steroids are the predominant androgens in polycystic ovary syndrome
O’Reilly, M. W., Kempegowda, P., Jenkinson, C., Taylor, A. E., Quanson, J. L., Storbeck, K.-H., & Arlt, W. (2017) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-3285 · Cited by 267
Liquid chromatography–tandem mass spectrometry for clinical diagnostics
Thomas, S. N., French, D., Jannetto, P. J., Rappold, B. A., & Clarke, W. A. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00175-x · Cited by 272
Intracrine androgen biosynthesis, metabolism and action revisited
Schiffer, L., Arlt, W., & Storbeck, K.-H. (2018) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2017.08.016 · Cited by 217
Frederiksen, H., Johannsen, T. H., Andersen, S. E., Albrethsen, J., Landersoe, S. K., Petersen, J. H., Andersen, A. N., Vestergaard, E. T., Schorring, M. E., Linneberg, A., et al. (2020) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgz196 · Cited by 211
Metadata
- Authors
- Keevil, B. G.
- Affiliations
- Manchester Academic Health Science Centre (GB)
- Corresponding author
- Keevil, Brian G.
- ORCID
- Keevil, Brian G.
- Venue
- Clinical Biochemistry
- Publisher
- Elsevier BV
- Published
- 2016-09
- Volume
- 49
- Issue
- 13-14
- Pages
- 989-997
- ISSN
- 0009-9120 (ISSN-L)
- OpenAlex
- W2344158997
- Cited by
- 149
- References
- 123
- Citations by year
- 2026: 13 · 2025: 6 · 2024: 16 · 2023: 16 · 2022: 23 · 2021: 16 · 2020: 18 · 2019: 17 · 2018: 12 · 2017: 11 · 2016: 1
- FWCI
- 11.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Biochemistry (publishedVersion)
- PubMed (publishedVersion)
- Research Explorer (The University of Manchester) (submittedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- steroid analysis, LC-MS/MS, laboratory diagnosis, endocrinology, sample preparation, reference measurement procedure, reference materials, multi-site calibration, disease diagnosis and monitoring
- MeSH terms
- Calibration, Chromatography, Liquid, Humans, Hydrocortisone, Laboratories, Steroids, Tandem Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review