ESB clinical biomechanics award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6–10 months
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Why Are Total Knee Arthroplasties Failing Today?
Sharkey, P. F., Hozack, W. J., Rothman, R. H., Shastri, S., & Jacoby, S. M. (2002) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200211000-00003 · Cited by 1,354
The mechanics of the knee joint in relation to normal walking
Morrison, J. B. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90050-3 · Cited by 1,055 · cited 2×
“Throughout the last few decades, the generally accepted value for the axial loading of the knee joint has been approximately 300 %BW (Morrison, 1970) during level walking.”
BackgroundThe prediction of muscular load sharing and joint forces in the lower extremities during walking
Seireg, A., & Arvikar, R. J. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90089-5 · Cited by 499 · cited 2×
“, 1997) with a maximum value of up to 670 %BW (Seireg and Arvikar, 1975).”
BackgroundProtopapadaki, A., Drechsler, W. I., Cramp, M. C., Coutts, F. J., & Scott, O. M. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.09.010 · Cited by 421 · cited 1×
“, 2002) as most studies were either two-dimensional or they did not focus on this load component (Nagura et al., 2002; Protopapadaki et al., 2007).”
BackgroundTibio‐femoral loading during human gait and stair climbing
Taylor, W. R., Heller, M. O., Bergmann, G., & Duda, G. N. (2004) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2003.09.003 · Cited by 366 · cited 1×
“More recently, advanced three-dimensional (3D) modelling provided more information on the loading of TKR (Taylor et al., 2004).”
BackgroundSelf-citationKnee and hip kinetics during normal stair climbing
Costigan, P. A., Deluzio, K. J., & Wyss, U. P. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00201-6 · Cited by 323
Vessely, M. B., Whaley, A. L., Harmsen, W. S., Schleck, C. D., & Berry, D. J. (2006) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000229356.81749.11 · Cited by 275 · cited 1×
“One of the major reasons for revision is wear of the ultra high molecular weight polyethylene (UHMWPE) inserts (Kellett et al., 2004; Sharkey et al., 2002; Vessely et al., 2006), due to the geometry of the articulating surfaces and the high forces and moments acting in the knee joint.”
BackgroundMündermann, A., Dyrby, C. O., D'Lima, D. D., Colwell, C. W., & Andriacchi, T. P. (2008) · Journal of Orthopaedic Research · doi:10.1002/jor.20655 · Cited by 249 · cited 1×
“Some years ago, an instrumented tibial baseplate was implanted into one subject allowing the measurement of the axial force component (D’Lima et al., 2005; Mundermann et al., 2008).”
MethodTaylor, S. J. G., Walker, P. S., Perry, J. S., Cannon, S. R., & Woledge, R. (1998) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(98)90009-2 · Cited by 246 · cited 2×
“The first TKR for in vivo measurements was an instrumented massive femoral replacement, measuring the forces and moments in its stem more than 20 cm away from the joint line (Taylor et al., 1998).”
BackgroundMethodMechanical loads at the knee joint during deep flexion
Nagura, T., Dyrby, C. O., Alexander, E. J., & Andriacchi, T. P. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00178-4 · Cited by 233 · cited 1×
“, 2002) as most studies were either two-dimensional or they did not focus on this load component (Nagura et al., 2002; Protopapadaki et al., 2007).”
BackgroundTibial Forces Measured In Vivo After Total Knee Arthroplasty
D'Lima, D. D., Patil, S., Steklov, N., Slamin, J. E., & Colwell, C. W. (2006) · The Journal of Arthroplasty · doi:10.1016/j.arth.2005.07.011 · Cited by 231 · cited 1×
“They found the axial load Fz of the knee joint to be slightly lower than 300 %BW (D’Lima et al., 2006; Taylor et al., 1998).”
BackgroundThe Functional Flexion-Extension Axis of the Knee Corresponds to the Surgical Epicondylar Axis
Asano, T., Akagi, M., & Nakamura, T. (2005) · The Journal of Arthroplasty · doi:10.1016/j.arth.2004.08.005 · Cited by 223 · cited 1×
“The coordinate system used is fixed to the tibial tray and not to the instantaneous helical or functional axis of the knee joint, around which the flexion–extension moment acts (Asano et al., 2005; van den Bogert et al., 2008).”
BackgroundIn vivo knee moments and shear after total knee arthroplasty
D’Lima, D. D., Patil, S., Steklov, N., Chien, S., & Colwell, C. W. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.03.004 · Cited by 188
JOINT LOAD CONSIDERATIONS IN TOTAL KNEE REPLACEMENT
Kuster, M. S., Wood, G. A., Stachowiak, G., & Gächter, A. (1997) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.79b1.6978 · Cited by 179
Implantable 9-Channel Telemetry System for In Vivo Load Measurements With Orthopedic Implants
Graichen, F., Arnold, R., Rohlmann, A., & Bergmann, G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886857 · Cited by 173 · cited 1×
“Their signals are sensed and multiplexed by a custom-made telemetry chip and transferred via a feedthrough and antenna wirelessly to the external receiver (Graichen et al., 2007).”
BackgroundSelf-citationThe Mark Coventry Award: In Vivo Knee Forces During Recreation and Exercise After Knee Arthroplasty
D'Lima, D. D., Steklov, N., Patil, S., & Colwell, C. W. (2008) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-008-0345-x · Cited by 172
Design, calibration and pre-clinical testing of an instrumented tibial tray
Heinlein, B., Graichen, F., Bender, A., Rohlmann, A., & Bergmann, G. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.02.014 · Cited by 150 · cited 1×
“1) used in the current study have been described elsewhere (Heinlein et al., 2007).”
MethodSelf-citationTHE CHITRANJAN RANAWAT AWARD: In Vivo Knee Forces after Total Knee Arthroplasty
DʼLima, D. D., Patil, S. S., Steklov, N., Slamin, J. E., & Colwell, C. W. (2005) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000186559.62942.8c · Cited by 128 · cited 1×
“Some years ago, an instrumented tibial baseplate was implanted into one subject allowing the measurement of the axial force component (D’Lima et al., 2005; Mundermann et al., 2008).”
MethodInstrumented implant for measuring tibiofemoral forces
Kaufman, K. R., Kovacevic, N., Irby, S. E., & Colwell, C. W. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00124-7 · Cited by 117 · cited 1×
“Some of them have used tibial baseplates instrumented with force transducers to measure loads in cadaveric studies or intraoperatively (Crottet et al., 2007, 2005; Jeffcote et al., 2007; Kaufman et al., 1996; Nicholls et al., 2007; Singerman et al., 1999, 1994).”
MethodVaradarajan, K. M., Moynihan, A. L., DʼLima, D. D., Colwell, C. W., & Li, G. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.04.021 · Cited by 113 · cited 1×
“More recently, load measurements using a six degree of freedom (DOF) prosthesis in up to three subjects with a follow-up of up to twelve months were also reported (D’Lima et al., 2007, 2008; Varadarajan et al., 2008).”
MethodHelical axes of skeletal knee joint motion during running
van den Bogert, A. J., Reinschmidt, C., & Lundberg, A. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.03.018 · Cited by 86
In Vitro Forces in the Normal and Cruciate-Deficient Knee During Simulated Squatting Motion
Singerman, R., Berilla, J., Archdeacon, M., & Peyser, A. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2835109 · Cited by 43
Barink, M., van Kampen, A., Malefijt, M. D. W., & Verdonschot, N. J. J. (2005) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/095441105x34437 · Cited by 25
Knee Joint Loading Patterns During Activities of Daily Living in TKR Patients
Benson, L., LeBerge, M., & Pace, T. B. (2003) · Advances in Bioengineering · doi:10.1115/imece2003-42955 · Cited by 2 · cited 1×
“Only a few gait analysis studies have reported results for the rotation moment Mz (Benson et al., 2003; Costigan et al., 2002) as most studies were either two-dimensional or they did not focus on this load component (Nagura et al.”
Background
Cited by
Loading of the Knee Joint during Activities of Daily Living Measured In Vivo in Five Subjects
Kutzner, I., Heinlein, B., Graichen, F., Bender, A., Rohlmann, A., Halder, A., Beier, A., & Bergmann, G. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.046 · Cited by 798
Grand challenge competition to predict in vivo knee loads
Fregly, B. J., Besier, T. F., Lloyd, D. G., Delp, S. L., Banks, S. A., Pandy, M. G., & D'Lima, D. D. (2012) · Journal of Orthopaedic Research · doi:10.1002/jor.22023 · Cited by 596
Knee joint loading during gait in healthy controls and individuals with knee osteoarthritis
Kumar, D., Manal, K. T., & Rudolph, K. S. (2013) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2012.11.008 · Cited by 257
Knee Adduction Moment and Medial Contact Force – Facts about Their Correlation during Gait
Kutzner, I., Trepczynski, A., Heller, M. O., & Bergmann, G. (2013) · PLoS ONE · doi:10.1371/journal.pone.0081036 · Cited by 256
Self-citationKnee joint forces: prediction, measurement, and significance
D’Lima, D. D., Fregly, B. J., Patil, S., Steklov, N., & Colwell, C. W. (2012) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/0954411911433372 · Cited by 215
“A ‘‘second-generation’’ tibial component was later designed and implanted in which all six components of force acting on the tibial tray were measured.43,50,51 A different six-component knee arthroplasty design was also implanted by the team led by Georg Bergmann.52,53 In the early postoperative period, peak axial con…”
BackgroundMethodInfluential
Metadata
- Authors
- Heinlein, B., Kutzner, I., Graichen, F., Bender, A., Rohlmann, A., Halder, A. M., Beier, A., & Bergmann, G.
- Venue
- Clinical Biomechanics
- Publisher
- Elsevier BV
- Published
- 2009-05
- Volume
- 24
- Issue
- 4
- Pages
- 315-326
- ISSN
- 0268-0033 (ISSN-L)
- OpenAlex
- W2093250500
- Cited by
- 200
- References
- 24
- FWCI
- 14.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.