The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
In vivo knee loading characteristics during activities of daily living as measured by an instrumented total knee replacement
Open accessAbstract
We examined the relationship between activity, peak load, medial to lateral load distribution, and flexion angle at peak load for activities of daily living. An instrumented knee prosthesis was used to measure knee joint force simultaneously with motion capture during walking, chair sit to stand and stand to sit, stair ascending and descending, squatting from a standing position, and golf swings. The maximum total compressive load at the knee was highest during stair ascending and descending and lowest during rising from a chair. Maximum total compressive load occurred at substantially different flexion angles ranging from 8.5° during walking to 91.8° during squatting. For all activities, total compressive load exceeded 2 times body weight, and for most activities 2.5 times body weight. Most activities placed a greater load on the medial compartment than the lateral compartment. Activities were grouped into three categories: high cycle loading (walk), high load (stair ascent, descent, and golf), and high flexion angle (chair sit to stand/stand to sit, and squat). The results demonstrate that the forces and motion sustained by the knee are highly activity‐dependent and that the unique loading characteristics for specific activities should be considered for the design of functional and robust total knee replacements, as well as for rehabilitation programs for patients with knee osteoarthritis or following total knee arthroplasty. © 2008 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 26:1167–1172, 2008
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanical loads at the knee joint during deep flexion
Nagura, T., Dyrby, C. O., Alexander, E. J., & Andriacchi, T. P. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00178-4 · Cited by 233
Self-citationNagura, T., Matsumoto, H., Kiriyama, Y., Chaudhari, A., & Andriacchi, T. P. (2006) · Journal of Applied Biomechanics · doi:10.1123/jab.22.4.305 · Cited by 91
Self-citation
Cited by
Loading of the Knee Joint during Activities of Daily Living Measured In Vivo in Five Subjects
Kutzner, I., Heinlein, B., Graichen, F., Bender, A., Rohlmann, A., Halder, A., Beier, A., & Bergmann, G. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.046 · Cited by 798
Effects of aging on articular cartilage homeostasis
Lotz, M., & Loeser, R. F. (2012) · Bone · doi:10.1016/j.bone.2012.03.023 · Cited by 398
Standardized Loads Acting in Knee Implants
Bergmann, G., Bender, A., Graichen, F., Dymke, J., Rohlmann, A., Trepczynski, A., Heller, M. O., & Kutzner, I. (2014) · PLoS ONE · doi:10.1371/journal.pone.0086035 · Cited by 382
Estimation of Knee Joint Forces in Sport Movements Using Wearable Sensors and Machine Learning
Stetter, B. J., Ringhof, S., Krafft, F. C., Sell, S., & Stein, T. (2019) · Sensors · doi:10.3390/s19173690 · Cited by 130
Techniques to determine knee joint contact forces during squatting: A systematic review
Kothurkar, R., & Lekurwale, R. (2022) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/09544119221091609 · Cited by 9
Metadata
- Authors
- Mündermann, A., Dyrby, C. O., D'Lima, D. D., Colwell, C. W., & Andriacchi, T. P.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2008-04-10
- Volume
- 26
- Issue
- 9
- Pages
- 1167-1172
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2043350870
- Cited by
- 249
- References
- 2
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo knee loading characteristics during activities of daily living as measured by an instrumented total knee replacement. https://app.cochat.ai/papers/10.1002/jor.20655
- The paper
- Mündermann, A., Dyrby, C. O., D'Lima, D. D., Colwell, C. W., & Andriacchi, T. P. (2008). In vivo knee loading characteristics during activities of daily living as measured by an instrumented total knee replacement. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.20655
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.