Cited by 117Hip disorders and treatmentsLower Extremity Biomechanics and PathologiesOrthopaedic implants and arthroplasty

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Hip kinematics and kinetics in persons with and without cam femoroacetabular impingement during a deep squat task

Abstract

Background Previous studies have indicated that hip and pelvis kinematics may be altered during functional tasks in persons with femoroacetabular impingement. The purpose of this study was to compare hip and pelvis kinematics and kinetics during a deep squat task between persons with cam femoroacetabular impingement and pain-free controls.Methods Fifteen persons with cam femoroacetabular impingement and 15 persons without cam femoroacetabular impingement performed a deep squat task. Peak hip flexion, abduction, and internal rotation, and mean hip extensor, adductor, and external rotator moments were quantified. Independent t-tests (α<0.05) were used to evaluate between group differences.Findings Compared to the control group, persons with cam femoroacetabular impingement demonstrated decreased peak hip internal rotation (15.2° (SD 9.5°) vs. 9.4° (SD 7.8°); P=0.041) and decreased mean hip extensor moments (0.56 (SD 0.12) Nm/kg vs. 0.45 (SD 0.15) Nm/kg; P=0.018). In addition persons in the cam femoroacetabular impingement group demonstrated decreased posterior pelvis tilt during squat descent compared to the control group, resulting in a more anteriorly tilted pelvis at the time peak hip flexion (12.5° (SD 17.1°) vs. 23.0° (SD 12.4°); P=0.024).Interpretation The decreased hip internal rotation observed in persons with cam femoroacetabular impingement may be the result of bony impingement. Furthermore, the decrease in posterior pelvis tilt may contribute to impingement by further approximating the femoral head-neck junction with the acetabulum. Additionally, decreased hip extensor moments suggest that diminished hip extensor muscle activity may contribute to decreased posterior pelvis tilt.

Overview

Integrity signals

Registry

Crossref · 10.1016/j.clinbiomech.2015.09.016

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Clinical guidelines for persons post ACL reconstruction advocate for the restoration of knee extensor strength and symmetry.

    “Clinical guidelines for persons post ACL reconstruction advocate for the restoration of knee extensor strength and symmetry.48,49”

Citations

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Metadata

Authors
Bagwell, J. J., Snibbe, J., Gerhardt, M., & Powers, C. M.
Affiliations
University of Southern California (US)
Corresponding author
  • Bagwell, Jennifer J.
  • Snibbe, Jason
  • Gerhardt, Michael
  • Powers, Christopher M.
Venue
Clinical Biomechanics
Publisher
Elsevier BV
Published
2016-01
Volume
31
Pages
87-92
ISSN
0268-0033 (ISSN-L)
OpenAlex
W2160784221
Cited by
115
References
41
Citations by year
2026: 10 · 2025: 5 · 2024: 10 · 2023: 9 · 2022: 13 · 2021: 13 · 2020: 10 · 2019: 13 · 2018: 18 · 2017: 13 · 2016: 1
FWCI
10.74
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Biomechanics (publishedVersion)
  • PubMed (publishedVersion)
  • Creighton Digital Repository (CDR) (submittedVersion)
Funders
  • International Society of Biomechanics (53-3407-7080)
  • California Physical Therapy Fund (13-03)
Topics
  • Health Sciences › Medicine › Surgery › Hip disorders and treatments
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
  • Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
Keywords
hip kinematics, hip kinetics, deep squat, hip internal rotation, posterior pelvic tilt, hip extension moment, hip flexion, hip abduction, bony impingement
MeSH terms
Acetabulum, Adult, Biomechanical Phenomena, Female, Femur, Hip Joint, Humans, Male, Middle Aged, Rotation, Case-Control Studies, Range of Motion, Articular, Weight-Bearing, Femoracetabular Impingement

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review