Magnetoneurography: theory and application to peripheral nerve disorders
Abstract
Magnetoneurography (MNG) is a non-invasive method to trace and visualize three-dimensionally the propagation path of compound action currents (CAC) along peripheral nerves. The basic physical and physiological principle is the mapping of extremely weak magnetic fields generated by the intraaxonal longitudinal ion flows of evoked nerval CAC using SQUID sensors (Superconducting Quantum Interference Devices). During recent years, MNG protocols have been established which allow for a non-invasive spatiotemporal tracing of impulse propagation along peripheral nerves in humans and in particular along proximal nerve segments in a clinical setting. Thereby, the three-dimensional path, the local nerve conduction velocity, the length and strength of the CAC de- and repolarization phase have been reconstructed. First recordings in patients demonstrated that the method is sensitive enough to detect and to localize nerve conduction anomalities along nerve roots, as, e.g. caused by lumbosacral disc herniation. This review on MNG will focus on those studies which provide data from humans and thereby reveal perspectives for its future clinical applications.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The main clinical perspective of magnetoneurography lies in the diagnosis of proximal mononeuropathies (plexus and root lesions), where conventional electrophysiological tests sometimes fail.
“The main clinical perspective of magnetoneurography lies in the diagnosis of proximal mononeuropathies (plexus and root lesions), where conventional electrophysiological tests sometimes fail”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Mackert, 2004
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
“The main clinical perspective of magnetoneurography lies in the diagnosis of proximal mononeuropathies (plexus and root lesions), where conventional electrophysiological tests sometimes fail (Mackert, 2004).”
BackgroundUltrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277 · see citing works
“To study a etocardiography [ ], t r ra hy [30], magn toencephalography [183] and magnetomyography [184], the magnetic field ensor must fulfill those conditions.”
BackgroundMethodNano Superconducting Quantum Interference device: A powerful tool for nanoscale investigations
Granata, C., & Vettoliere, A. (2015) · Physics Reports · doi:10.1016/j.physrep.2015.12.001 · Cited by 247 · see citing works
“ve been applied also to other human organs such as stomach and intestines (magnetoenterography), lung (magnetopneumography) [95], muscles (magnetomyography) and peripheral nerves (magnetoneurography) [96]. Other useful biomedical applications include liver iron concentration detection which allows a completely non inv…”
BackgroundInterfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113 · see citing works
Thin Film Magnetoelectric Sensors Toward Biomagnetism: Materials, Devices, and Applications
Dong, C., Liang, X., Gao, J., Chen, H., He, Y., Wei, Y., Zaeimbashi, M., Matyushov, A. D., Sun, C., & Sun, N. X. (2022) · Advanced Electronic Materials · doi:10.1002/aelm.202200013 · Cited by 68 · see citing works
Magnetospinography visualizes electrophysiological activity in the cervical spinal cord
Sumiya, S., Kawabata, S., Hoshino, Y., Adachi, Y., Sekihara, K., Tomizawa, S., Masaki, T., Ishii, S., Sakaki, K., Ukegawa, D., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-02406-8 · Cited by 56
Magnetic Measurement of Electrically Evoked Muscle Responses With Optically Pumped Magnetometers
Elzenheimer, E., Laufs, H., Schulte‐Mattler, W., & Schmidt, G. U. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2968148 · Cited by 56 · see citing works
“This has already been successfully demonstrated with the aid of liquid helium-cooled SQUID studies [4], [36]–[40].”
MethodA Review of Magnetic Field Emissions From the Human Body: Sources, Sensors, and Uses
Zhu, K., & Kiourti, A. (2022) · IEEE Open Journal of Antennas and Propagation · doi:10.1109/ojap.2022.3186643 · Cited by 35 · see citing works
A 75-ch SQUID Biomagnetometer System for Human Cervical Spinal Cord Evoked Field
Adachi, Y., Kawai, J., Uehara, G., Miyamoto, M., Tomizawa, S., & Kawabata, S. (2007) · IEEE transactions on applied superconductivity · doi:10.1109/tasc.2007.910152 · Cited by 26
Novel functional imaging technique for the brachial plexus based on magnetoneurography.
Watanabe, T., Kawabata, S., Hoshino, Y., Ushio, S., Sasaki, T., Miyano, Y., Ozaki, I., Adachi, Y., Sekihara, K., & Okawa, A. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.08.006 · Cited by 25
Adachi, Y., Miyamoto, M., Kawai, J., Uehara, G., Ogata, H., Kawabata, S., Sekihara, K., & Kado, H. (2011) · IEEE transactions on applied superconductivity · doi:10.1109/tasc.2010.2082480 · Cited by 24
“These results are in good agreement with those of previous studies on the measurement of the SCEF and the peripheral nerve evoked magnetic field [11]–[13].”
ResultVisualization of electrophysiological activity at the carpal tunnel area using magnetoneurography.
Sasaki, T., Kawabata, S., Hoshino, Y., Sekihara, K., Adachi, Y., Akaza, M., Ozaki, I., Fujita, K., Nimura, A., Yoshii, T., et al. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.11.030 · Cited by 18
“Magnetic fields have been measured from the peripheral nerve of the upper extremities of humans (Trahms et al., 1989; Wikswo, 1990; Hoshiyama et al., 1999; Mackert, 2004; Nakanishi et al., 2004).”
Backgroundde Asis, E. D., Leung, J., Wood, S. L., & Nguyen, C. V. (2010) · Nanotechnology · doi:10.1088/0957-4484/21/12/125101 · Cited by 16 · see citing works
State of the Art and Perspectives of Ultrasound Imaging as a Human-Machine Interface
Castellini, C. (2014) · doi:10.1007/978-94-017-8932-5_2 · Cited by 13
“, mechanomyography [27], magnetomyography [32] and”
Magnetoneurography as a novel functional imaging technique for the ulnar nerve at the elbow.
Hoshino, Y., Kawabata, S., Adachi, Y., Watanabe, T., Sekihara, K., Sasaki, T., Hashimoto, J., Fujita, K., Nimura, A., & Okawa, A. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2022.03.017 · Cited by 11
“The development of MNG for the spinal cord and peripheral nerves has been gradual compared with magnetoencephalography and magnetocardiography, mainly owing to the anatomical features of these nerves (Mackert, 2004; Afra, 2020).”
BackgroundZhang, J., Meng, X., Han, T., Wei, X., Wang, L., Zhao, Y., Fu, G., Tian, N., Wang, Q., Qin, S., et al. (2023) · IET Nanodielectrics · doi:10.1049/nde2.12049 · Cited by 11 · see citing works
Detailed magnetoelectric analysis of a nerve impulse propagation along the brachial plexus.
Ozaki, I., Akaza, M., Watanabe, T., Miyano, Y., Adachi, Y., & Kawabata, S. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2022.09.018 · Cited by 10
“…et al., 2021; Curio et al., 1991; Hashimoto et al., 1991, 1994; Hoshiyama et al., 1999; Ishii et al., 2012; Kimura et al., 2008; Klein et al., 2006; Mackert, 2004; Mackert et al., 1997, 1998, 2000, 2001a, 2001b; Nakanishi et al., 2004; Sasaki et al., 2020; Sumiya et al., 2017; Trahms et al., 1989;…”
Zhu, K., & Kiourti, A. (2022) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2022.3187315 · Cited by 9 · see citing works
“Magnetoneurography (MNG) can be used to visualize the propagation path of evoked compound action currents (CAC) along peripheral nerves [16] and quantitate peripheral nerve regeneration [17].”
BackgroundAssessing carpal tunnel syndrome with magnetoneurography.
Sasaki, T., Kawabata, S., Hashimoto, J., Hoshino, Y., Sekihara, K., Adachi, Y., Akaza, M., Fujita, K., Nimura, A., Yoshii, T., et al. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2022.03.021 · Cited by 9
Magnetoneurograhy of an Electrically Stimulated Arm Nerve
Elzenheimer, E., Laufs, H., Sander-Thömmes, T., & Schmidt, G. (2018) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2018-0087 · Cited by 9
“In previous SQUID work [5,6], field amplitudes of 10 fT to 100 fT were measured.”
MethodTowards non-invasive imaging through spinal-cord generated magnetic fields
Spedden, M. E., O’Neill, G. C., Tierney, T. M., West, T. O., Schmidt, M., Mellor, S., Farmer, S. F., Bestmann, S., & Barnes, G. R. (2024) · Frontiers in Medical Technology · doi:10.3389/fmedt.2024.1470970 · Cited by 11 · see citing works
Mandeville, R. M., Sanchez, B., Johnston, B. R., Bazarek, S. F., Thum, J. A., Birmingham, A., See, R. B., Leochico, C. F. D., Kumar, V., Dowlatshahi, A. S., et al. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acdbeb · Cited by 7 · see citing works
“Nevertheless, limitations are clear and predominantly include expense, time, availability, expertise, and size of equipment [156, 158, 159].”
Smit, X., de Kool, B. S., Blok, J., Visser, G. H., Hovius, S., & van Neck, J. (2006) · Journal of the peripheral nervous system · doi:10.1111/j.1085-9489.2006.00077.x · Cited by 6
“Notably, using this technique, propagating CACs and conduction blocks have already been studied in vivo (Fukuoka et al., 2002; 2004) and non-invasively in patients (Mackert et al., 1998; Mackert, 2004).”
MethodPeripheral nerve repair: innovations and future directions
Aldali, F., 唐莉, Yang, Y., Huang, Y., Li, Y., Deng, C., & Chen, H. (2026) · Journal of Translational Medicine · doi:10.1186/s12967-025-07567-z · Cited by 4 · see citing works
“Furthermore, well-designed, double-blind, randomized controlled trials with adequate sample sizes are urgently needed, and their results should be made transparently available to guide clinical practice and inform the public [351–355]”
Volume conductor models for magnetospinography
O’Neill, G. C., Spedden, M. E., Schmidt, M., Mellor, S., Stenroos, M., & Barnes, G. R. (2025) · Scientific Reports · doi:10.1038/s41598-025-10770-z · Cited by 5 · see citing works
“This ranges from non-invasive imaging to understand the mechanisms of pain 44,52,53 , to non-invasively localizing the site of nerve conduction anomalies in in conditions such as compressive myelopathy 17,54,55 .”
A Review of Magnetoelectric Composites Based on ZnO Nanostructures
Bardakas, A., Kaidatzis, A., & Tsamis, C. (2023) · Applied Sciences · doi:10.3390/app13148378 · Cited by 5 · see citing works
Nakayama, K., Kohara, N., Paku, M., Sato, S., Nakamura, M., Ando, M., Taniguchi, S., Ishihara, M., Tani, Y., Itakura, T., et al. (2023) · Clinical Neurophysiology · doi:10.1016/j.clinph.2023.05.006 · Cited by 4
“…of magnetic field measurements (Curio et al., 1991; Hari et al., 1989; Hashimoto et al., 1994; Hashimoto et al., 1991; Hoshiyama et al., 1999; Mackert, 2004; Mackert et al., 2000; Nakanishi et al., 2004; Trahms et al., 1989) and current reconstructions in peripheral nerves (Hoshino et al.,…”
High-Precision Biomagnetic Measurement System Based on Tunnel Magneto-Resistive Effect
Zuo, S.-M., Nazarpour, K., & Heidari, H. (2020) · International Conference on Electronics, Circuits, and Systems · doi:10.1109/icecs49266.2020.9294789 · Cited by 4 · see citing works
“Detecting weak biomagnetic fields derived from human active organs and tissues, mainly including Magnetocardiography (MCG) [2], [3], Magnetoencephalography (MEG) [4], [5], Magnetomyography (MMG) [6], [7], Magnetoneurography (MNG) [8], requires effective methods that offer both high spatial and temporal resolutions.”
BackgroundElectroplated FePt Films for Micromechanical Magnetic Sensors
Toda, M., Xu, H., & Ono, T. (2021) · Physica Status Solidi (a) · doi:10.1002/pssa.202000547 · Cited by 2 · see citing works
The advancement of magnetoneurography.
Afra, P. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.12.406 · Cited by 2 · see citing works
deAsis, E., Leung, J., Wood, S., & Nguyen, C. (2010) · doi:10.1063/1.3292216 · Cited by 2
Afra, P., & Watson, G. D. R. (2025) · Annals of Clinical Neurophysiology · doi:10.14253/acn.25005
- Authors
- Mackert, B.-M.
- Affiliations
- Stiftung Charité (DE)
- Corresponding author
- Mackert, Bruno-Marcel
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2004-12
- Volume
- 115
- Issue
- 12
- Pages
- 2667-2676
- ISSN
- 1388-2457 (ISSN-L)
- OpenAlex
- W2081173244
- Cited by
- 36
- References
- 0
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 2 · 2023: 4 · 2022: 6 · 2021: 2 · 2020: 5 · 2019: 2 · 2017: 1 · 2015: 1 · 2014: 1
- FWCI
- 0.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Peripheral Nerve Disorders
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Neurology › Peripheral Neuropathies and Disorders
- Keywords
- peripheral nerve disorders, compound action potential, nerve conduction velocity, SQUID sensors, impulse propagation, nerve root injury, lumbosacral disc herniation, evoked magnetic fields
- MeSH terms
- Evoked Potentials, Humans, Magnetics, Neural Conduction, Peripheral Nervous System Diseases
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review