The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
High-yield decomposition of surface EMG signals
Open accessAbstract
Objective Automatic decomposition of surface Electromyographic (sEMG) signals into their constituent motor unit action potential trains (MUAPTs). Methods A small five-pin sensor provides four channels of sEMG signals that are in turn processed by an enhanced artificial intelligence algorithm evolved from a previous proof-of-principle. We tested the technology on sEMG signals from five muscles contracting isometrically at force levels ranging up to 100% of their maximal level, including those that were covered with more than 1.5 cm of adipose tissue. Decomposition accuracy was measured by a new method wherein a signal is first decomposed and then reconstructed and the accuracy is measured by comparison. Results were confirmed by the more established two-source method. Results The number of MUAPTs decomposed varied among muscles and force levels and mostly ranged from 20 to 30, with a maximum of 40. The accuracy of all the firings of the MUAPTs was on average 92.5%, at times reaching 97%. Conclusion Reported technology can reliably perform high-yield decomposition of sEMG signals for isometric contractions up to maximal force levels. Significance The small sensor size and the high yield and accuracy of the decomposition should render this technology useful for motor control studies and clinical investigations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Case-Based Reasoning: Experiences, Lessons and Future Directions
Leake, D. B. (1996) · Cumulative Index of Computer Aided Architectural Design · Cited by 897
Behaviour of human motor units in different muscles during linearly varying contractions
de Luca, C. J., LeFever, R. S., McCue, M. P., & Xenakis, A. P. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014293 · Cited by 719
Self-citationA wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697
Multichannel Blind Source Separation Using Convolution Kernel Compensation
Holobar, A., & Zazula, D. (2007) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2007.896108 · Cited by 648
Classification of the myoelectric signal using time-frequency based representations
Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 645
Common drive of motor units in regulation of muscle force
DELUCA, C., & ERIM, Z. (1994) · Trends in Neurosciences · doi:10.1016/0166-2236(94)90064-7 · Cited by 519
Self-citationDecomposition of Surface EMG Signals
De Luca, C. J., Adam, A., Wotiz, R., Gilmore, L. D., & Nawab, S. H. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00009.2006 · Cited by 511
Self-citationModern Techniques in Neuroscience Research
(1999) · Springer eBooks · doi:10.1007/978-3-642-58552-4 · Cited by 452
Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450
MORPHOLOGIC STUDIES OF MOTOR UNITS IN NORMAL HUMAN MUSCLES
Feinstein, B., Lindegård, B., Nyman, E., & Wohlfart, G. (1955) · Cells Tissues Organs · doi:10.1159/000140989 · Cited by 433
Cited by
Skeletal muscle performance and ageing
Tieland, M., Trouwborst, I., & Clark, B. C. (2018) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12238 · Cited by 904
Holobar, A., Minetto, M. A., & Farina, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016008 · Cited by 400
De Luca, C. J., & Hostage, E. C. (2010) · Journal of Neurophysiology · doi:10.1152/jn.01018.2009 · Cited by 326
Self-citationA Novel Framework Based on FastICA for High Density Surface EMG Decomposition
Chen, M., & Zhou, P. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2412038 · Cited by 260
Yavuz, U. Ş., Negro, F., Sebik, O., Holobar, A., Frömmel, C., Türker, K. S., & Farina, D. (2015) · The Journal of Physiology · doi:10.1113/jp270635 · Cited by 55
Metadata
- Authors
- Nawab, S. H., Chang, S.-S., & De Luca, C. J.
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2010-10
- Volume
- 121
- Issue
- 10
- Pages
- 1602-1615
- ISSN
- 1388-2457 (ISSN-L)
- OpenAlex
- W2148270081
- Cited by
- 370
- References
- 44
- FWCI
- 7.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-yield decomposition of surface EMG signals. https://app.cochat.ai/papers/10.1016/j.clinph.2009.11.092
- The paper
- Nawab, S. H., Chang, S.-S., & De Luca, C. J. (2010). High-yield decomposition of surface EMG signals. Clinical Neurophysiology. https://doi.org/10.1016/j.clinph.2009.11.092
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.