UltraTrack: Software for semi-automated tracking of muscle fascicles in sequences of B-mode ultrasound images
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
BACKGROUND Dynamic measurements of human muscle fascicle length from sequences of B-mode ultrasound images have become increasingly prevalent in biomedical research. Manual digitisation of these images is time consuming and algorithms for automating the process have been developed. Here we present a freely available software implementation of a previously validated algorithm for semi-automated tracking of muscle fascicle length in dynamic ultrasound image recordings, "UltraTrack". METHODS UltraTrack implements an affine extension to an optic flow algorithm to track movement of the muscle fascicle end-points throughout dynamically recorded sequences of images. The underlying algorithm has been previously described and its reliability tested, but here we present the software implementation with features for: tracking multiple fascicles in multiple muscles simultaneously; correcting temporal drift in measurements; manually adjusting tracking results; saving and re-loading of tracking results and loading a range of file formats. RESULTS Two example runs of the software are presented detailing the tracking of fascicles from several lower limb muscles during a squatting and walking activity. CONCLUSION We have presented a software implementation of a validated fascicle-tracking algorithm and made the source code and standalone versions freely available for download.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1981) · Cited by 11,963
Determination of fascicle length and pennation in a contracting human muscle in vivo
Fukunaga, T., Ichinose, Y., Ito, M., Kawakami, Y., & Fukashiro, S. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.1.354 · Cited by 452
Lichtwark, G. A., Bougoulias, K., & Wilson, A. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.10.035 · Cited by 418
Self-citationMuscle architecture and function in humans
Fukunaga, T., Kawakami, Y., Kuno, S., Funato, K., & Fukashiro, S. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00171-6 · Cited by 246
Automatic tracking of medial gastrocnemius fascicle length during human locomotion
Cronin, N. J., Carty, C. P., Barrett, R. S., & Lichtwark, G. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00530.2011 · Cited by 213
Self-citationGillett, J. G., Barrett, R., & Lichtwark, G. A. (2012) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2011.633516 · Cited by 151
Self-citationZhou, G., Chan, P., & Zheng, Y. (2014) · Ultrasonics · doi:10.1016/j.ultras.2014.10.020 · Cited by 74
Automated regional analysis of B-mode ultrasound images of skeletal muscle movement
Darby, J., Hodson-Tole, E. F., Costen, N. P., & Loram, I. D. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00701.2011 · Cited by 57
Deconstructing the power resistance relationship for squats: A joint‐level analysis
Farris, D. J., Lichtwark, G. A., Brown, N. A. T., & Cresswell, A. G. (2015) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.12508 · Cited by 49
Self-citation
Cited by
Estimation of joint torque in dynamic activities using wearable A-mode ultrasound
Jin, Y., Alvarez, J. T., Suitor, E. L., Swaminathan, K., Chin, A., Civici, U. S., Nuckols, R. W., Howe, R. D., & Walsh, C. J. (2024) · Nature Communications · doi:10.1038/s41467-024-50038-0 · Cited by 58
Fully Automated Analysis of Muscle Architecture from B-Mode Ultrasound Images with DL_Track_US
Ritsche, P., Franchi, M. V., Faude, O., Finni, T., Seynnes, O., & Cronin, N. J. (2024) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2023.10.011 · Cited by 20
Metadata
- Authors
- Farris, D. J., & Lichtwark, G. A.
- Venue
- Computer Methods and Programs in Biomedicine
- Publisher
- Elsevier BV
- Published
- 2016-05
- Volume
- 128
- Pages
- 111-118
- ISSN
- 0169-2607 (ISSN-L)
- OpenAlex
- W2292296004
- Cited by
- 236
- References
- 9
- FWCI
- 12.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.