Estimation of joint torque in dynamic activities using wearable A-mode ultrasound
Open accessThe DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
The human body constantly experiences mechanical loading. However, quantifying internal loads within the musculoskeletal system remains challenging, especially during unconstrained dynamic activities. Conventional measures are constrained to laboratory settings, and existing wearable approaches lack muscle specificity or validation during dynamic movement. Here, we present a strategy for estimating corresponding joint torque from muscles with different architectures during various dynamic activities using wearable A-mode ultrasound. We first introduce a method to track changes in muscle thickness using single-element ultrasonic transducers. We then estimate elbow and knee torque with errors less than 7.6% and coefficients of determination (R2) greater than 0.92 during controlled isokinetic contractions. Finally, we demonstrate wearable joint torque estimation during dynamic real-world tasks, including weightlifting, cycling, and both treadmill and outdoor locomotion. The capability to assess joint torque during unconstrained real-world activities can provide new insights into muscle function and movement biomechanics, with potential applications in injury prevention and rehabilitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




![Fig. 5 Knee torque estimation during treadmill and outdoor locomotion. A Illustration of participants performing various walking and running tasks on an instrumented treadmill with RF thickness measured with SETs and joint kinematics measured with wireless IMUs. B Example estimated knee torque during the stance phase (left column) and corresponding ground truth (right column) for treadmill locomotion at various speeds (0.75, 1.25, 1.75 m s−1 walking and 2.50, 3.00 m s−1 running) and slopes [+10% (top row), 0% (middle row), −10% (bottom row)] from a representative participant. Lines and shaded regions represent mean ± SD across the steps within each condition. C RMSEs for different locomotion types across all participants (n = 5). Student’s two-tailed t tests: walk vs run (p = 0.873). D RMSEs for different slope levels across all participants (n = 5). One-way ANOVA: no significant main effect (p = 0.965, F2,8 = 0.036). For C and D, each box bounds the IQR divided by the median with whiskers extending up to 1.5*IQR. Each dot represents the RMSE for one participant. E Photograph of a participant performing outdoor locomotion with a backpack containing the A-mode ultrasound electronics. Placements of SETs and IMUs remained unchanged compared to the treadmill test. F Knee torque estimation at different speeds during level ground outdoor locomotion. Lines and shaded regions represent mean ± SD (n = 15 steps). G Knee torque estimation during comfortable-speed downhill and uphill walking and running. Lines and shaded regions represent mean ± SD (n = 15 steps).](https://figures.cochat.ai/paper-figures/518caa39bfd442ed9aa4116c03e72a57/estimation-of-joint-torque-in-dynamic-activities-using-wearable-a-mode-figure-5.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement
Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.901024 · Cited by 4,933
Functional and clinical significance of skeletal muscle architecture
Lieber, R. L., & Frid�n, J. (2000) · Muscle & Nerve · doi:10.1002/1097-4598(200011)23:11<1647::aid-mus1>3.0.co;2-m · Cited by 1,254
Buchanan, T. S., Lloyd, D. G., Manal, K., & Besier, T. F. (2004) · Journal of Applied Biomechanics · doi:10.1123/jab.20.4.367 · Cited by 941
Model-based estimation of muscle forces exerted during movements
Erdemir, A., McLean, S., Herzog, W., & van den Bogert, A. J. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.09.005 · Cited by 872
IMU-Based Joint Angle Measurement for Gait Analysis
Seel, T., Raisch, J., & Schauer, T. (2014) · Sensors · doi:10.3390/s140406891 · Cited by 867
Recovery and Performance in Sport: Consensus Statement
Kellmann, M., Bertollo, M., Bosquet, L., Brink, M., Coutts, A. J., Duffield, R., Erlacher, D., Halson, S. L., Hecksteden, A., Heidari, J., et al. (2018) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2017-0759 · Cited by 824
Measurement of muscle contraction with ultrasound imaging
Hodges, P. W., Pengel, L. H. M., Herbert, R. D., & Gandevia, S. C. (2003) · Muscle & Nerve · doi:10.1002/mus.10375 · Cited by 816
Anatomical Data for Analyzing Human Motion
Plagenhoef, S., Evans, F. G., & Abdelnour, T. (1983) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.1983.10605290 · Cited by 647
Bioadhesive ultrasound for long-term continuous imaging of diverse organs
Wang, C., Chen, X., Wang, L., Makihata, M., Liu, H.-C., Zhou, T., & Zhao, X. (2022) · Science · doi:10.1126/science.abo2542 · Cited by 599
Narici, M. V., Binzoni, T., Hiltbrand, E., Fasel, J., Terrier, F., & Cerretelli, P. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021685 · Cited by 555
Research works printed but not linked: 2
- Zernicke, R. & Whiting, W. Mechanisms of musculoskeletal injury. Biomech. Sport. Perform. Enhancement Inj. Prev. 507, 522 (2000).
- Muscolino, J. E. The Muscular System Manual: The Skeletal Muscles of the Human Body (Elsevier Health Sciences).
Cited by
Emerging Wearable Acoustic Sensing Technologies
Liu, T., Mao, Y., Dou, H., Zhang, W., Yang, J., Wu, P., Li, D., & Mu, X. (2025) · Advanced Science · doi:10.1002/advs.202408653 · Cited by 93
Guo, X., Zhang, Z., Ren, Z., Li, D., Xu, C., Wang, L., Liu, W., Zhuge, Y., Zhou, G., & Lee, C. (2025) · Advanced Materials · doi:10.1002/adma.202510417 · Cited by 73
Unperceivable Designs of Wearable Electronics
Liu, Y., de Mulatier, S., & Matsuhisa, N. (2025) · Advanced Materials · doi:10.1002/adma.202502727 · Cited by 64
Alternative Micro/Nanofabrication Approaches for Wearable Electronics
Zhang, J., & Wang, M. (2026) · Chemical Reviews · doi:10.1021/acs.chemrev.5c00801 · Cited by 53
AI-Enabled Piezoelectric Wearable for Joint Torque Monitoring
Chang, J., Li, J., Ye, J., Zhang, B., Chen, J., Xia, Y., Lei, J., Carlson, T., Loureiro, R. C. V., Korsunsky, A. M., et al. (2025) · Nano-Micro Letters · doi:10.1007/s40820-025-01753-w · Cited by 46
Metadata
- Authors
- Jin, Y., Alvarez, J. T., Suitor, E. L., Swaminathan, K., Chin, A., Civici, U. S., Nuckols, R. W., Howe, R. D., & Walsh, C. J.
- Affiliations
- Harvard University (US)
- University of Massachusetts Lowell (US)
- Corresponding author
- Walsh, Conor J.
- ORCID
- Venue
- Nature Communications
- Published
- 2024-07-09
- Volume
- 15
- Issue
- 1
- Pages
- 5756-5756
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC11233567
- OpenAlex
- W4400445480
- Cited by
- 58
- References
- 71
- Citations by year
- 2026: 25 · 2025: 28 · 2024: 5
- FWCI
- 6.35
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- U.S. Department of Health & Human Services | National Institutes of Health (R21AR076686)
- Harvard University | Harvard School of Engineering and Applied Sciences
- National Science Foundation (DGE2140743)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Biomedical Engineering › Mechanics and Biomechanics Studies
- Keywords
- joint torque estimation, wearable ultrasound, A-mode ultrasound, elbow torque, knee joint torque, isokinetic contraction, weightlifting, cycling, locomotion, musculoskeletal load, injury prevention, rehabilitation
- MeSH terms
- Wearable Electronic Devices, Adult, Biomechanical Phenomena, Elbow Joint, Female, Humans, Joints, Knee Joint, Male, Movement, Muscle Contraction, Ultrasonography, Muscle, Skeletal, Torque, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of joint torque in dynamic activities using wearable A-mode ultrasound. https://app.cochat.ai/papers/10.1038/s41467-024-50038-0
- The paper
- Jin, Y., Alvarez, J. T., Suitor, E. L., Swaminathan, K., Chin, A., Civici, U. S., Nuckols, R. W., Howe, R. D., & Walsh, C. J. (2024). Estimation of joint torque in dynamic activities using wearable A-mode ultrasound. Nature Communications. https://doi.org/10.1038/s41467-024-50038-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.