BACKGROUND AND OBJECTIVE In medical examinations doctors use various techniques in order to provide to the patients an accurate analysis of their actual state of health. One of the commonly used methodologies is the x-ray screening. This examination very often help to diagnose some diseases of chest organs. The most frequent cause of wrong diagnosis lie in the radiologist's difficulty in interpreting the presence of lungs carcinoma in chest X-ray. In such circumstances, an automated approach could be highly advantageous as it provides important help in medical diagnosis. METHODS In this paper we propose a new classification method of the lung carcinomas. This method start with the localization and extraction of the lung nodules by computing, for each pixel of the original image, the local variance obtaining an output image (variance image) with the same size of the original image. In the variance image we find the local maxima and then by using the locations of these maxima in the original image we found the contours of the possible nodules in lung tissues. However after this segmentation stage we find many false nodules. Therefore to discriminate the true ones we use a probabilistic neural network as classifier. RESULTS The performance of our approach is 92% of correct classifications, while the sensitivity is 95% and the specificity is 89.7%. The misclassification errors are due to the fact that network confuses false nodules with the true ones (6%) and true nodules with the false ones (2%). CONCLUSIONS Several researchers have proposed automated algorithms to detect and classify pulmonary nodules but these methods fail to detect low-contrast nodules and have a high computational complexity, in contrast our method is relatively simple but at the same time provides good results and can detect low-contrast nodules. Furthermore, in this paper is presented a new algorithm for training the PNN neural networks that allows to obtain PNNs with many fewer neurons compared to the neural networks obtained by using the training algorithms present in the literature. So considerably lowering the computational burden of the trained network and at same time keeping the same performances.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cmpb.2018.04.025

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 93

Metadata

Authors
Woźniak, M., Połap, D., Capizzi, G., Sciuto, G. L., Kośmider, L., & Frankiewicz, K.
Venue
Computer Methods and Programs in Biomedicine
Publisher
Elsevier BV
Published
2018-07
Volume
161
Pages
173-180
ISSN
0169-2607 (ISSN-L)
OpenAlex
W2803094129
Cited by
93
References
1
FWCI
6.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Small lung nodules detection based on local variance analysis and probabilistic neural network. https://app.cochat.ai/papers/10.1016/j.cmpb.2018.04.025
The paper
Woźniak, M., Połap, D., Capizzi, G., Sciuto, G. L., Kośmider, L., & Frankiewicz, K. (2018). Small lung nodules detection based on local variance analysis and probabilistic neural network. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2018.04.025

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.