Abstract
BACKGROUND AND OBJECTIVE This study demonstrates deep learning approaches with an aim to find the optimal method to automatically detect sleep apnea (SA) events from an electrocardiogram (ECG) signal. METHODS Six deep learning approaches were designed and implemented for automatic detection of SA events including deep neural network (DNN), one-dimensional (1D) convolutional neural networks (CNN), two-dimensional (2D) CNN, recurrent neural networks (RNN), long short-term memory, and gated-recurrent unit (GRU). Designed deep learning models were analyzed and compared in the performances. The ECG signal was pre-processed, normalized, and segmented into 10 s intervals. Subsequently, the signal was converted into a 2D form for analysis in the 2D CNN model. A dataset collected from 86 patients with SA was used. The training set comprised data from 69 of the patients, while the test set contained data from the remaining 17 patients. RESULTS The accuracy of the best-performing model was 99.0%, and the 1D CNN and GRU models had 99.0% recall rates. CONCLUSIONS The designed deep learning approaches performed better than those developed and tested in previous studies in terms of detecting SA events, and they could distinguish between apnea and hypopnea events using an ECG signal. The deep learning approaches such as 1D CNN and GRU can be helpful tools to automatically detect SA in sleep apnea screening and related studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Speech recognition with deep recurrent neural networks
Graves, A., Mohamed, A.-R., & Hinton, G. (2013) · 2013 IEEE International Conference on Acoustics, Speech and Signal Processing · doi:10.1109/icassp.2013.6638947 · Cited by 8,893
Recurrent neural network based language model
Mikolov, T., Karafiát, M., Burget, L., Černocký, J., & Khudanpur, S. (2010) · Interspeech 2010 · doi:10.21437/interspeech.2010-343 · Cited by 5,390
The epidemiology of adult obstructive sleep apnea
Punjabi, N. M. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200709-155mg · Cited by 2,361
Gottlieb, D. J., Yenokyan, G., Newman, A. B., O'Connor, G. T., Punjabi, N. M., Quan, S. F., Redline, S., Resnick, H. E., Tong, E. K., Diener-West, M., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.901801 · Cited by 1,551
DeepCpG: accurate prediction of single-cell DNA methylation states using deep learning
Angermueller, C., Lee, H. J., Reik, W., & Stegle, O. (2017) · Genome Biology · doi:10.1186/s13059-017-1189-z · Cited by 536
Obstructive Sleep Apnea as a Risk Factor for Type 2 Diabetes
Botros, N., Concato, J., Mohsenin, V., Selim, B., Doctor, K., & Yaggi, H. K. (2009) · The American Journal of Medicine · doi:10.1016/j.amjmed.2009.04.026 · Cited by 384
Real-time sleep apnea detection by classifier combination
Xie, B., & Minn, H. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2188299 · Cited by 294
Cited by
Hong, S., Zhou, Y., Shang, J., Xiao, C., & Sun, J. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103801 · Cited by 464
Clinical applications of artificial intelligence in sleep medicine: A sleep clinician’s perspective
Bandyopadhyay, A., & Goldstein, C. (2023) · Sleep And Breathing · doi:10.1007/s11325-022-02592-4 · Cited by 108
“However, to automate scoring of data collected in the home, investigators have used ECG or PPG signal in isolation, or combined with a limited complement of traditional respiratory parameters [47–50].”
MethodA comprehensive review of AI-Based detection of Arrhythmia using Electrocardiogram (ECG)
Ayyub, A., Politis, C., & Usman, M. A. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110594 · Cited by 18
Metadata
- Authors
- Erdenebayar, U., Kim, Y. J., Park, J.-U., Joo, E. Y., & Lee, K.-J.
- Venue
- Computer Methods and Programs in Biomedicine
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 180
- Pages
- 105001
- ISSN
- 0169-2607 (ISSN-L)
- OpenAlex
- W2966674791
- Cited by
- 178
- References
- 7
- FWCI
- 13.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.