Non-invasive brain stimulation and neuroenhancement
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Attempts to enhance human memory and learning ability have a long tradition in science. This topic has recently gained substantial attention because of the increasing percentage of older individuals worldwide and the predicted rise of age-associated cognitive decline in brain functions. Transcranial brain stimulation methods, such as transcranial magnetic (TMS) and transcranial electric (tES) stimulation, have been extensively used in an effort to improve cognitive functions in humans. Here we summarize the available data on low-intensity tES for this purpose, in comparison to repetitive TMS and some pharmacological agents, such as caffeine and nicotine. There is no single area in the brain stimulation field in which only positive outcomes have been reported. For self-directed tES devices, how to restrict variability with regard to efficacy is an essential aspect of device design and function. As with any technique, reproducible outcomes depend on the equipment and how well this is matched to the experience and skill of the operator. For self-administered non-invasive brain stimulation, this requires device designs that rigorously incorporate human operator factors. The wide parameter space of non-invasive brain stimulation, including dose (e.g., duration, intensity (current density), number of repetitions), inclusion/exclusion (e.g., subject's age), and homeostatic effects, administration of tasks before and during stimulation, and, most importantly, placebo or nocebo effects, have to be taken into account. The outcomes of stimulation are expected to depend on these parameters and should be strictly controlled. The consensus among experts is that low-intensity tES is safe as long as tested and accepted protocols (including, for example, dose, inclusion/exclusion) are followed and devices are used which follow established engineering risk-management procedures. Devices and protocols that allow stimulation outside these parameters cannot claim to be "safe" where they are applying stimulation beyond that examined in published studies that also investigated potential side effects. Brain stimulation devices marketed for consumer use are distinct from medical devices because they do not make medical claims and are therefore not necessarily subject to the same level of regulation as medical devices (i.e., by government agencies tasked with regulating medical devices). Manufacturers must follow ethical and best practices in marketing tES stimulators, including not misleading users by referencing effects from human trials using devices and protocols not similar to theirs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Agenda-Setting Function of Mass Media
McCombs, M. E., & Shaw, D. L. (1972) · Public Opinion Quarterly · doi:10.1086/267990 · Cited by 9,537
Rasch, B., & Born, J. (2013) · Physiological Reviews · doi:10.1152/physrev.00032.2012 · Cited by 2,783 · cited 2×
“Brain oscillations that dominate non-rapid eye movement sleep (NREM) are thought to mediate the beneficial effect of sleep on various functions (Rasch and Born, 2013; Tononi and Cirelli, 2020).”
BackgroundFunctional connectome fingerprinting: Identifying individuals using patterns of brain connectivity
Finn, E. S., Shen, X., Scheinost, D., Rosenberg, M. D., Huang, J., Chun, M. M., Papademetris, X., & Constable, R. T. (2015) · Nature Neuroscience · doi:10.1038/nn.4135 · Cited by 2,747
Lefaucheur, J.-P., Aleman, A., Baeken, C., Benninger, D. H., Brunelin, J., Di Lazzaro, V., Filipović, S. R., Grefkes, C., Hasan, A., Hummel, F. C., et al. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.11.002 · Cited by 2,382 · cited 1×
“These concerns and related questions have also been discussed in previous reviews (Sehm and Ragert, 2013; Levasseur-Moreau et al., 2013).”
Self-citationBoosting slow oscillations during sleep potentiates memory
Marshall, L., Helgadóttir, H., Mölle, M., & Born, J. (2006) · Nature · doi:10.1038/nature05278 · Cited by 1,792 · cited 1×
“As opposed to the constant current stimulation over time of tDCS, transcranial alternating current (tACS) (Antal et al., 2008) and random noise (tRNS) (Terney et al., 2008) stimulation apply balanced alternating current or paradigms with a DC offset (Marshall et al., 2006).”
BackgroundRossi, S., Antal, A., Bestmann, S., Bikson, M., Brewer, C., Brockmöller, J., Carpenter, L. L., Cincotta, M., Chen, R., Daskalakis, J. D., et al. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.10.003 · Cited by 1,573 · cited 1×
“In addition, the induction of seizures is rare, but still a potential issue in rTMS (Rossi et al., 2021) but not in low-intensity tES (Antal et al., 2017).”
Self-citationReis, J., Schambra, H. M., Cohen, L. G., Buch, E. R., Fritsch, B., Zarahn, E., Celnik, P. A., & Krakauer, J. W. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805413106 · Cited by 1,401 · cited 1×
“The strength and duration of an aftereffects have been shown to be cumulative over a series of separate, consecutive, sessions of stimulation (e.g., Reis et al., 2009).”
BackgroundLiebetanz, D. (2002) · Brain · doi:10.1093/brain/awf238 · Cited by 1,383 · cited 1×
“It is assumed that long-term potentiation (LTP) and long-term depression (LTD) phenomena at the synaptic level are the physiological mechanisms for durable changes following NIBS (Liebetanz et al., 2002; Nitsche et al., 2003; Sharma et al., 2022; Rossini et al., 2019).”
BackgroundNitsche, M. A., Schauenburg, A., Lang, N., Liebetanz, D., Exner, C., Paulus, W., & Tergau, F. (2003) · Journal of Cognitive Neuroscience · doi:10.1162/089892903321662994 · Cited by 1,032 · cited 3×
“Early reports on facilitation of motor learning (Nitsche et al., 2003) were recently confirmed and extended to improvement of jump performance (Grosprêtre et al., 2021).”
BackgroundSelf-citationBatsikadze, G., Moliadze, V., Paulus, W., Kuo, M. ‐., & Nitsche, M. A. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2012.249730 · Cited by 1,017
Self-citation
Cited by
Yang, T., Liu, W., He, J., Gui, C., Meng, L., Xu, L., & Jia, C. (2024) · Alzheimer's Research & Therapy · doi:10.1186/s13195-024-01505-9 · Cited by 59
Metadata
- Authors
- Antal, A., Luber, B., Brem, A.-K., Bikson, M., Brunoni, A. R., Cohen Kadosh, R., Dubljević, V., Fecteau, S., Ferreri, F., Flöel, A., Hallett, M., Hamilton, R. H., Herrmann, C. S., Lavidor, M., Loo, C., Lustenberger, C., Machado, S., Miniussi, C., Moliadze, V., Nitsche, M. A., Rossi, S., Rossini, P. M., Santarnecchi, E., Seeck, M., Thut, G., Turi, Z., Ugawa, Y., Venkatasubramanian, G., Wenderoth, N., Wexler, A., Ziemann, U., & Paulus, W.
- Venue
- Clinical Neurophysiology Practice
- Publisher
- Elsevier BV
- Published
- 2022
- Volume
- 7
- Pages
- 146-165
- ISSN
- 2467-981X (ISSN-L)
- OpenAlex
- W4281486035
- Cited by
- 220
- References
- 40
- FWCI
- 13.31
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.