Cited by 47Polymer Surface Interaction StudiesSurface Treatment and CoatingsTitanium Alloys Microstructure and Properties

Improved endothelialization of NiTi alloy by VEGF functionalized nanocoating

Shen, Weixing, Cai, Kaiyong, Yang, Zaixiang, Yan, Ying, Yang, Weihu, Liu, Peng·2012·Colloids and Surfaces B: Biointerfaces

Abstract

To improve surface endothelialization of NiTi alloy substrate, a nano-structured coating functionalized with vascular endothelial growth factor (VEGF) was fabricated via polydopamine (PDOP) as intermediate layer. The successful preparation of VEGF conjugated nanocoating was demonstrated by X-ray diffraction (XRD), atomic force microscope (AFM), scanning electron microscopy (SEM), and X-ray photoelectron spectroscopy (XPS), respectively. Inductively coupled plasma mass spectrometry (ICP-MS) test showed that the formed nanocoating significantly reduced the release of Ni ion from NiTi alloy in simulated body fluid. The biological behaviors of endothelial cells adhered to modified NiTi alloy substrates, including cell proliferation, cell spreading and production of nitric oxide and prostacyclin were investigated in vitro. The results suggest that surface functionalization of NiTi alloy substrate with VEGF is beneficial for cell growth. The approach presented here affords an alternative for surface modification of NiTi implants applied as heart and vascular implant devices.

Integrity signals

Registry

Crossref · 10.1016/j.colsurfb.2012.02.009

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • PDA-assisted surface modification is expanding its applications to not only bone biosubstitutes but also cardiovascular devices, biosensors, neuron pseudosubstitutes, and sustainable drug delivery.

    “the PDA-assisted surface modification is expanding its applications to not only bone biosubstitutes but also cardiovascular devices, biosensors, neuron pseudosubstitutes, and sustainable drug delivery [18, 99–101].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Shen, W., Cai, K., Yang, Z., Yan, Y., Yang, W., & Liu, P.
Affiliations
Chongqing University (CN)
Corresponding author
Liu, Peng
Venue
Colloids and Surfaces B: Biointerfaces
Publisher
Elsevier BV
Published
2012-06
Volume
94
Pages
347-353
ISSN
0927-7765 (ISSN-L)
OpenAlex
W2078269640
Cited by
47
References
1
Citations by year
2026: 3 · 2025: 2 · 2023: 1 · 2022: 1 · 2021: 4 · 2020: 5 · 2019: 1 · 2018: 2 · 2017: 4 · 2016: 7 · 2015: 5 · 2014: 7 · 2013: 5
FWCI
2.40
Type
journal article
Language
en
Open access
closed
Locations
  • Colloids and Surfaces B Biointerfaces (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Physical Sciences › Engineering › Mechanical Engineering › Surface Treatment and Coatings
  • Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties
Keywords
NiTi, endothelialization, vascular endothelial growth factor, polydopamine, nanostructured coatings, surface modification, nickel release, endothelial cell proliferation, nitric oxide, prostacyclin, vascular implants
MeSH terms
Alloys, Body Fluids, Cell Adhesion, Humans, Indoles, Microscopy, Electron, Scanning, Nickel, Nitric Oxide, Polymers, Epoprostenol, Surface Properties, Titanium, X-Ray Diffraction, Microscopy, Atomic Force, Coated Materials, Biocompatible, Tissue Engineering, Biomimetic Materials, Vascular Endothelial Growth Factor A, Cell Proliferation, Photoelectron Spectroscopy, Human Umbilical Vein Endothelial Cells

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review