Role of protein adsorption in the bio corrosion of metallic implants – A review
The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Abstract
Implants are exposed to a complex physiological environment that contains various organic compounds, especially proteins. The adsorption of proteins has an immense influence on the corrosion, biocompatibility and wear properties of implantable metals. Proteins engage in multiple processes that could potentially inhibit or promote metal degradation, depending on the type of proteins, their concentration and the properties of the implant material. In the bio corrosion process, proteins are denatured and transform into a film on the metal surface, inhibiting corrosion. This film is found on many retrieved artificial joints, especially on worn areas, and can protect the passive film from scrapping due to its lubricating effect, thus decreasing tribocorroion. On the other hand, the interactions of metal ions with proteins (and amino acids) create colloidal organometallic complexes. Transport of the complex compounds away from the interface increases dissolution rates; thus, it accelerates the corrosion of metallic implants. The influence of protein adsorption on the corrosion behaviour of metallic biomaterials is presented in this review. Biocompatible metals that are favourably used as implants such as stainless steel, Co-Cr alloys, Ti alloys and biodegradable Mg and Fe alloys are specifically addressed. We have highlighted the adsorption phenomenon of protein on metallic implants, the interaction of proteins with metallic implants and the role of protein adsorption on implant biocorrosion behaviour as well as their wear resistance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The surface science of titanium dioxide
Diebold, U. (2003) · Surface Science Reports · doi:10.1016/s0167-5729(02)00100-0 · Cited by 7,944
Understanding biophysicochemical interactions at the nano–bio interface
Nel, A. E., Mädler, L., Velegol, D., Xia, T., Hoek, E. M. V., Somasundaran, P., Klaessig, F., Castranova, V., & Thompson, M. (2009) · Nature Materials · doi:10.1038/nmat2442 · Cited by 7,083
Osteoblast adhesion on biomaterials
Anselme, K. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00242-2 · Cited by 2,500
Pitting Corrosion of Metals: A Review of the Critical Factors
Frankel, G. S. (1998) · Journal of The Electrochemical Society · doi:10.1149/1.1838615 · Cited by 2,135
Mediation of biomaterial-cell interactions by adsorbed proteins: a review
Wilson, C. J., Clegg, R. E., Leavesley, D. I., & Pearcy, M. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1 · Cited by 1,696
Arima, Y., & Iwata, H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.013 · Cited by 1,593
Saris, N.-E. L., Mervaala, E., Karppanen, H., Khawaja, J. A., & Lewenstam, A. (2000) · Clinica Chimica Acta · doi:10.1016/s0009-8981(99)00258-2 · Cited by 1,366
Recent advances on the development of magnesium alloys for biodegradable implants
Chen, Y., Xu, Z., Smith, C., & Sankar, J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.005 · Cited by 1,236
Nanosize and Vitality: TiO2 Nanotube Diameter Directs Cell Fate
Park, J., Bauer, S., von der Mark, K., & Schmuki, P. (2007) · Nano Letters · doi:10.1021/nl070678d · Cited by 1,193
On the adsorption of proteins on solid surfaces, a common but very complicated phenomenon
Nakanishi, K., Sakiyama, T., & Imamura, K. (2001) · Journal of Bioscience and Bioengineering · doi:10.1016/s1389-1723(01)80127-4 · Cited by 1,006
Agarwal, S., Curtin, J., Duffy, B., & Jaiswal, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.06.020 · Cited by 955
Comparison of metal release from various metallic biomaterials in vitro
Okazaki, Y., & Gotoh, E. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.02.005 · Cited by 862
Globular proteins at solid/liquid interfaces
Haynes, C. A., & Norde, W. (1994) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/0927-7765(94)80066-9 · Cited by 852
Zreiqat, H., Howlett, C. R., Zannettino, A., Evans, P., Schulze‐Tanzil, G., Knabe, C., & Shakibaei, M. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10270 · Cited by 825
A new look at biomedical Ti-based shape memory alloys
Biesiekierski, A., Wang, J., Gepreel, M. A.-H., & Wen, C. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.01.018 · Cited by 719
The relationship between the nanostructure of titanium surfaces and bacterial attachment
Puckett, S. D., Taylor, E., Raimondo, T., & Webster, T. J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.09.081 · Cited by 683
Calcium phosphate coatings on magnesium alloys for biomedical applications: A review
Shadanbaz, S., & Dias, G. J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.10.016 · Cited by 651
Biomaterials in total joint replacement
Katti, K. S. (2004) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2003.12.002 · Cited by 637
Peuster, M., Wohlsein, P., Brügmann, M., Ehlerding, M., Seidler, K., Fink, C., Brauer, H., Fischer, A., & Hausdorf, G. (2001) · Heart · doi:10.1136/heart.86.5.563 · Cited by 569
Park, J., Bauer, S., Schlegel, K. A., Neukam, F. W., von der Mark, K., & Schmuki, P. (2009) · Small · doi:10.1002/smll.200801476 · Cited by 527
Protein adsorption on solid surfaces
Hlady, V., & Buijs, J. (1996) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(96)80098-x · Cited by 522
The corrosion behaviour of Ti–6Al–4V, Ti–6Al–7Nb and Ti–13Nb–13Zr in protein solutions
Khan, M. A., Williams, R. L., & Williams, D. F. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00217-8 · Cited by 485
Biodegradable Mg and Mg alloys: Corrosion and biocompatibility
Virtanen, S. (2011) · Materials Science and Engineering: B · doi:10.1016/j.mseb.2011.05.028 · Cited by 423
Kilpadi, K. L., Chang, P.-L., & Bellis, S. L. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200111)57:2<258::aid-jbm1166>3.0.co;2-r · Cited by 419
Hydroxyapatite coating on titanium substrate with titania buffer layer processed by sol–gel method
Kim, H.-W., Koh, Y.-H., Li, L.-H., Lee, S., & Kim, H.-E. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.041 · Cited by 404
Special modes of corrosion under physiological and simulated physiological conditions
Virtanen, S., Milošev, I., Gómez‐Barrena, E., Trebše, R., Salo, J., & Konttinen, Y. T. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.12.003 · Cited by 365
Degradable metallic biomaterials: Design and development of Fe–Mn alloys for stents
Hermawan, H., Dube, D., & Mantovani, D. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32224 · Cited by 358
Integrins as linker proteins between osteoblasts and bone replacing materials. A critical review
Siebers, M. C., ter Brugge, P. J., Walboomers, X. F., & Jansen, J. A. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.02.021 · Cited by 352
Human plasma fibrinogen adsorption and platelet adhesion to polystyrene
Tsai, W.-B., Grunkemeier, J. M., & Horbett, T. A. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199902)44:2<130::aid-jbm2>3.0.co;2-9 · Cited by 329
Tissue-biomaterial interactions
Williams, D. F. (1987) · Journal of Materials Science · doi:10.1007/bf01161439 · Cited by 318
Effect of gold nanoparticle morphology on adsorbed protein structure and function
Gagner, J. E., Lopez, M. D., Dordick, J. S., & Siegel, R. W. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.091 · Cited by 297
Cell/Material Interfaces: Influence of Surface Chemistry and Surface Topography on Cell Adhesion
Anselme, K., Ploux, L., & Ponche, A. (2010) · Journal of Adhesion Science and Technology · doi:10.1163/016942409x12598231568186 · Cited by 291
Current strategies towards hemocompatible coatings
Werner, C., Maitz, M. F., & Sperling, C. (2007) · Journal of Materials Chemistry · doi:10.1039/b703416b · Cited by 258
Graphitic Tribological Layers in Metal-on-Metal Hip Replacements
Liao, Y., Pourzal, R., Wimmer, M. A., Jacobs, J. J., Fischer, A., & Marks, L. D. (2011) · Science · doi:10.1126/science.1213902 · Cited by 247
Bagherifard, S., Hickey, D. J., Fintová, S., Pastorek, F., Fernandez-Pariente, I., Bandini, M., Webster, T. J., & Guagliano, M. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.11.032 · Cited by 235
Effects of chloride ions on corrosion of ductile iron and carbon steel in soil environments
Song, Y., Jiang, G., Chen, Y., Zhao, P., & Tian, Y. (2017) · Scientific Reports · doi:10.1038/s41598-017-07245-1 · Cited by 232
Fonseca, C., & Barbosa, M. A. (2001) · Corrosion Science · doi:10.1016/s0010-938x(00)00107-4 · Cited by 216
Titanium metals form direct bonding to bone after alkali and heat treatments
Nishiguchi, S., Kato, H., Fujita, H., Oka, M., Kim, H.-M., Kokubo, T., & Nakamura, T. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00443-9 · Cited by 210
Zhu, S., Huang, N., Xu, L., Zhang, Y., Liu, H., Sun, H., & Leng, Y. (2009) · Materials Science and Engineering: C · doi:10.1016/j.msec.2008.12.019 · Cited by 192
An overview of protein adsorption on metal oxide coatings for biomedical implants
Silva-Bermudez, P., & Rodil, S. E. (2013) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2013.04.028 · Cited by 182
Pan, J., Liao, H., Leygraf, C., Thierry, D., & Li, J. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199805)40:2<244::aid-jbm9>3.0.co;2-l · Cited by 174
CoCrMo metal-on-metal hip replacements
Liao, Y., Hoffman, E., Wimmer, M., Fischer, A., Jacobs, J., & Marks, L. (2013) · Phys. Chem. Chem. Phys. · doi:10.1039/c2cp42968c · Cited by 161
Protein adsorption on magnesium and its alloys: A review
Höhn, S., Virtanen, S., & Boccaccini, A. R. (2018) · Applied Surface Science · doi:10.1016/j.apsusc.2018.08.173 · Cited by 156
Hedberg, Y. S., Wang, X., Hedberg, J. F., Lundin, M., Blomberg, E., & Wallinder, I. O. (2013) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-013-4859-8 · Cited by 154
A review on in vitro corrosion performance test of biodegradable metallic materials
Zhen, Z., Xi, T., & Zheng, Y. (2013) · Transactions of Nonferrous Metals Society of China · doi:10.1016/s1003-6326(13)62730-2 · Cited by 152
Metal release from stainless steel in biological environments: A review
Hedberg, Y. S., & Wallinder, I. O. (2015) · Biointerphases · doi:10.1116/1.4934628 · Cited by 146
Park, J., Bauer, S., Pittrof, A., Killian, M. S., Schmuki, P., & von der Mark, K. (2011) · Small · doi:10.1002/smll.201100790 · Cited by 142
In vivo study of the initial bacterial adhesion on different implant materials
Al‐Ahmad, A., Wiedmann‐Al‐Ahmad, M., Fackler, A., Follo, M., Hellwig, E., Bächle, M., Hannig, C., Han, J.-E., Wolkewitz, M., & Kohal, R. (2013) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2013.04.011 · Cited by 140
Protein–material interactions: From micro-to-nano scale
Tsapikouni, T. S., & Missirlis, Y. F. (2008) · Materials Science and Engineering B · doi:10.1016/j.mseb.2008.06.007 · Cited by 130
Adsorption of human serum albumin (HSA) onto colloidal TiO2 particles, Part I
Oliva, F. Y., Avalle, L. B., Cámara, O. R., & Pauli, C. P. D. (2003) · Journal of Colloid and Interface Science · doi:10.1016/s0021-9797(03)00029-8 · Cited by 128
New concepts in the design of drug-eluting coronary stents
Garg, S., Bourantas, C., & Serruys, P. W. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.13 · Cited by 125
Song, H., Park, S.-H., Jeong, S., & Park, Y.-J. (2008) · Journal of Materials Processing Technology · doi:10.1016/j.jmatprotec.2008.02.055 · Cited by 123
Ochsenbein, A., Chai, F., Winter, S., Traisnel, M., Brème, J., & Hildebrand, H. F. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.03.012 · Cited by 121
Lord, M. S., Modin, C., Foss, M., Duch, M., Simmons, A., Pedersen, F. S., MILTHORPE, B. K., & Besenbacher, F. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.04.006 · Cited by 115
Biomaterials—The Interfacial Problem
Hench, L. L., & Ethridge, E. C. (1975) · Elsevier eBooks · doi:10.1016/b978-0-12-004905-9.50007-4 · Cited by 114
Wang, W., Mohammadi, F., & Alfantazi, A. M. (2012) · Corrosion Science · doi:10.1016/j.corsci.2011.12.039 · Cited by 114
Scotchford, C. A., Ball, M., Winkelmann, M., Vörös, J., Csucs, C., Brunette, D. M., Danuser, G. M., & Textor, M. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00488-x · Cited by 110
Competitive binding of chromium, cobalt and nickel to serum proteins
Yang, J., & Black, J. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90049-3 · Cited by 109
The influence of proteins on the fretting–corrosion behaviour of a Ti6Al4V alloy
Hiromoto, S., & Mischler, S. (2006) · Wear · doi:10.1016/j.wear.2006.03.032 · Cited by 93
Physicochemical principles of tissue material interactions
Thulĺ, R. (2002) · Biomolecular Engineering · doi:10.1016/s1389-0344(02)00009-6 · Cited by 88
Mura-Galelli, M. J., Voegel, J., Behr, S., Brès, É. F., & Schaaf, P. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.13.5557 · Cited by 81
Adsorption and protein-induced metal release from chromium metal and stainless steel
Lundin, M., Hedberg, Y. S., Jiang, T., Herting, G., Wang, X., Thormann, E., Blomberg, E., & Wallinder, I. O. (2011) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2011.09.068 · Cited by 81
Influence of proteins and cells on in vitro corrosion of Mg–Nd–Zn–Zr alloy
Zhang, J., Kong, N., Shi, Y., Niu, J., Mao, L., Li, H., Xiong, M., & Yuan, G. (2014) · Corrosion Science · doi:10.1016/j.corsci.2014.04.020 · Cited by 77
García, A. F., Perez-Alvarez, J., Ortega, C. C. B., Medina, J. C., Almaguer‐Flores, A., Sánchez, R. B., & Rodil, S. E. (2016) · Materials Science and Engineering C · doi:10.1016/j.msec.2016.04.035 · Cited by 76
Role of proteins in the degradation of relatively inert alloys in the human body
Hedberg, Y. S. (2018) · npj Materials Degradation · doi:10.1038/s41529-018-0049-y · Cited by 72
Extracellular matrix remodelling during cell adhesion monitored by the quartz crystal microbalance
Lord, M. S., Modin, C., Foss, M., Duch, M., Simmons, A., Pedersen, F. S., Besenbacher, F., & MILTHORPE, B. K. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.002 · Cited by 70
Bilayer formation at adsorption of proteins from aqueous solutions on metal surfaces
Arnebrant, T., Ivarsson, B., Larsson, K., Lundström, I., & Nylander, T. (2007) · Steinkopff eBooks · doi:10.1007/bfb0114306 · Cited by 60
Adsorption of albumin and sodium hyaluronate on UHMWPE: A QCM-D and AFM study
Serro, A. P., Degiampietro, K., Colaço, R., & Saramago, B. (2010) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2010.01.022 · Cited by 57
The Effects of Serum Proteins on Magnesium Alloy Degradation in Vitro
Johnson, I., Jiang, W., & Liu, H. H. (2017) · Scientific Reports · doi:10.1038/s41598-017-14479-6 · Cited by 52
The role of protein adsorption on chondrocyte adhesion to a heterocyclic methacrylate polymer system
Wyre, R. M., & Downes, S. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00113-2 · Cited by 43
Immobilization of TiO2 nanofibers on titanium plates for implant applications
Lim, J. I., Yu, B., Woo, K. M., & Lee, Y. (2008) · Applied Surface Science · doi:10.1016/j.apsusc.2008.07.146 · Cited by 40
Farcas, M. A., Cosman, N. P., Ting, D. K., Roscoe, S. G., & Omanovic, S. (2010) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2010.04.004 · Cited by 38
Synovial Fluid Lubrication: The Effect of Protein Interactions on Adsorbed and Lubricating Films
Parkes, M., Myant, C., Cann, P. M., & Wong, J. S. S. (2015) · Biotribology · doi:10.1016/j.biotri.2015.05.001 · Cited by 36
Alcheikh, A., Pavon‐Djavid, G., Hélary, G., Petite, H., Migonney, V., & Anagnostou, F. (2013) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-013-4932-3 · Cited by 36
Lackner, J. M., & Waldhauser, W. (2010) · Journal of Adhesion Science and Technology · doi:10.1163/016942409x12598231568023 · Cited by 33
Synergistic effect of chloride ion and albumin on the corrosion of pure magnesium
Liu, C., Zhang, Y., Zhang, C., Wang, W., Huang, W., & Chu, P. K.-H. (2014) · Frontiers of Materials Science · doi:10.1007/s11706-014-0251-y · Cited by 21
Nune, C., Xu, W., & Misra, R. D. K. (2012) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34260 · Cited by 19
The role of serum proteins in Staphylococcus aureus adhesion to ethylene glycol coated surfaces
Schuster, S., Yu, W., Nega, M., Chu, Y., Zorn, S., Zhang, F., Götz, F., & Schreiber, F. (2014) · International Journal of Medical Microbiology · doi:10.1016/j.ijmm.2014.05.012 · Cited by 19
Schmidt, M., Nazneen, F., Georgiev, Y., Herzog, G., Galvin, P., & Petkov, N. (2012) · Journal of Physics Conference Series · doi:10.1088/1742-6596/371/1/012065 · Cited by 9
Jenney (2000) · doi:10.1002/(sici)1097-4636(20000315)49:4<435::aid-jbm2>3.0.co;2-y
Characteristics of copper corrosion in simulated uterine fluid in the presence of protein
Zhu, J., Xu, N., & Zhang, C. (1999) · Advances in Contraception · doi:10.1023/a:1006793231274
Cited by
Singh, N., Batra, U., Kumar, K., Ahuja, N., & Mahapatro, A. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2022.05.009 · Cited by 165
“Nevertheless, it is still debatable to determine whether the proteins assist or hinder the corrosion phenomena of Mg alloys [18].”
Background
Metadata
- Authors
- Talha, M., Ma, Y., Kumar, P., Lin, Y., & Singh, A.
- Venue
- Colloids and Surfaces B: Biointerfaces
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 176
- Pages
- 494-506
- ISSN
- 0927-7765 (ISSN-L)
- OpenAlex
- W2913651994
- Cited by
- 192
- References
- 81
- FWCI
- 20.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.