The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
ECG signal denoising and baseline wander correction based on the empirical mode decomposition
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Empirical Mode Decomposition as a Filter Bank
Flandrin, P., Rilling, G., & Goncalves, P. (2004) · IEEE Signal Processing Letters · doi:10.1109/lsp.2003.821662 · Cited by 2,583
The Hilbert-Huang Transform in Engineering
(2005) · CRC Press eBooks · doi:10.1201/9781420027532 · Cited by 355
Implementation of a WAP-based telemedicine system for patient monitoring
Hung, K., & Zhang, Y.-T. (2003) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2003.811870 · Cited by 290
Detrending and denoising with empirical mode decompositions
Flandrin, P., Gonçalvès, P., & Rilling, G. (2004) · HAL (Le Centre pour la Communication Scientifique Directe) · Cited by 264
Real-Time Classification of ECGs on a PDA
Rodriguez, J., Goni, A., & Illarramendi, A. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.838369 · Cited by 237
Application of empirical mode decomposition to heart rate variability analysis
Echeverría, J. C., Crowe, J. A., Woolfson, M. S., & Hayes-Gill, B. R. (2001) · Medical and Biological Engineering and Computing · doi:10.1007/bf02345370 · Cited by 189
ECG baseline wander and powerline interference reduction using nonlinear filter bank
Łęski, J. M., & Henzel, N. (2005) · Signal Processing · doi:10.1016/j.sigpro.2004.12.001 · Cited by 188
Removing artifacts from electrocardiographic signals using independent components analysis
Barros, A. K., Mansour, A., & Ohnishi, N. (1998) · Neurocomputing · doi:10.1016/s0925-2312(98)00056-3 · Cited by 180
Cited by
Ecg pattern analysis for emotion detection
Agrafioti, F., Hatzinakos, D., & Anderson, A. K. (2012) · IEEE Transactions on Affective Computing · doi:10.1109/t-affc.2011.28 · Cited by 476
Wei, Y., & Chen, M.-C. (2012) · Transportation Research Part C: Emerging Technologies · doi:10.1016/j.trc.2011.06.009 · Cited by 468
Empirical mode decomposition based ECG enhancement and QRS detection
Pal, S., & Mitra, M. (2012) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2011.10.012 · Cited by 256
Identification of hypertrophic cardiomyopathy on electrocardiographic images with deep learning
Sangha, V., Dhingra, L. S., Aminorroaya, A., Croon, P. M., Sikand, N. V., Sen, S., Martinez, M. W., Maron, M. S., Krumholz, H. M., Asselbergs, F. W., et al. (2025) · Nature Cardiovascular Research · doi:10.1038/s44161-025-00685-3 · Cited by 41
Mariyappa, N., Sengottuvel, S., Parasakthi, C., Gireesan, K., Janawadkar, M. P., Radhakrishnan, T. S., & Sundar, C. S. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.06.023 · Cited by 38
Metadata
- Authors
- Blanco-Velasco, M., Weng, B., & Barner, K. E.
- Venue
- Computers in Biology and Medicine
- Publisher
- Elsevier BV
- Published
- 2008-01
- Volume
- 38
- Issue
- 1
- Pages
- 1-13
- ISSN
- 0010-4825 (ISSN-L)
- OpenAlex
- W2015242484
- Cited by
- 649
- References
- 21
- FWCI
- 8.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ECG signal denoising and baseline wander correction based on the empirical mode decomposition. https://app.cochat.ai/papers/10.1016/j.compbiomed.2007.06.003
- The paper
- Blanco-Velasco, M., Weng, B., & Barner, K. E. (2008). ECG signal denoising and baseline wander correction based on the empirical mode decomposition. Computers in Biology and Medicine. https://doi.org/10.1016/j.compbiomed.2007.06.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.