The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Implementation of a WAP-based telemedicine system for patient monitoring
Abstract
Many parties have already demonstrated telemedicine applications that use cellular phones and the Internet. A current trend in telecommunication is the convergence of wireless communication and computer network technologies, and the emergence of wireless application protocol (WAP) devices is an example. Since WAP will also be a common feature found in future mobile communication devices, it is worthwhile to investigate its use in telemedicine. This paper describes the implementation and experiences with a WAP-based telemedicine system for patient-monitoring that has been developed in our laboratory. It utilizes WAP devices as mobile access terminals for general inquiry and patient-monitoring services. Authorized users can browse the patients' general data, monitored blood pressure (BP), and electrocardiogram (ECG) on WAP devices in store-and-forward mode. The applications, written in wireless markup language (WML), WMLScript, and Perl, resided in a content server. A MySQL relational database system was set up to store the BP readings, ECG data, patient records, clinic and hospital information, and doctors' appointments with patients. A wireless ECG subsystem was built for recording ambulatory ECG in an indoor environment and for storing ECG data into the database. For testing, a WAP phone compliant with WAP 1.1 was used at GSM 1800 MHz by circuit-switched data (CSD) to connect to the content server through a WAP gateway, which was provided by a mobile phone service provider in Hong Kong. Data were successfully retrieved from the database and displayed on the WAP phone. The system shows how WAP can be feasible in remote patient-monitoring and patient data retrieval.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043
Cited by
Istepanian, R. S. H., Jovanov, E., & Zhang, Y. T. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.840019 · Cited by 766
Self-citationWhat Is Telemedicine? A Collection of 104 Peer-Reviewed Perspectives and Theoretical Underpinnings
Sood, S., Mbarika, V., Jugoo, S., Dookhy, R., Doarn, C. R., Prakash, N., & Merrell, R. C. (2007) · Telemedicine and e-Health · doi:10.1089/tmj.2006.0073 · Cited by 627
(2006) · Globalization and Health · doi:10.1186/1744-8603-2-9 · Cited by 467
Tsai, J.-M., Cheng, M.-J., Tsai, H.-H., Hung, S.-W., & Chen, Y.-L. (2019) · International Journal of Information Management · doi:10.1016/j.ijinfomgt.2019.03.003 · Cited by 257
Enabling ubiquitous patient monitoring: Model, decision protocols, opportunities and challenges
Sneha, S., & Varshney, U. (2009) · Decision Support Systems · doi:10.1016/j.dss.2008.11.014 · Cited by 153
Metadata
- Authors
- Hung, K., & Zhang, Y.-T.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2003-06
- Volume
- 7
- Issue
- 2
- Pages
- 101-107
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2122806052
- Cited by
- 290
- References
- 1
- FWCI
- 19.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implementation of a WAP-based telemedicine system for patient monitoring. https://app.cochat.ai/papers/10.1109/titb.2003.811870
- The paper
- Hung, K., & Zhang, Y.-T. (2003). Implementation of a WAP-based telemedicine system for patient monitoring. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/titb.2003.811870
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.